scholarly journals EXPERIMENTAL DETERMINATION AND CALCULATION OF BASIC OPERATING PARAMETERS OF A CAR AIR CONDITIONER

Author(s):  
Y.I. Babenkov ◽  
◽  
A.I. Ozersky ◽  
V.V Romanov ◽  
G.A Galka ◽  
...  

In this work, experimental studies have been carried out to determine the main thermodynamic parameters of the refrigerating machine of an automobile air conditioner. The coefficient of performance, compressor operation, specific refrigeration capacity, mass flow, and compressor efficiency were determined. With the help of a multimedia device, the curves of the speed of the system, pressure sensors and temperature sensors were taken.

Author(s):  
Luis Rosario ◽  
Muhammad M. Rahman ◽  
Jose L. F. Porteiro

The performance of the air conditioner was tested in an extensive experimental program using the environmentally controlled chambers in a test facility. Two psychometric rooms provided constant ambient temperature and humidity conditions for a test unit using ASHRAE standard procedures [1]. The indoor and outdoor units were placed into separate environmental chambers, which provided precise temperature, humidity, and airflow conditions for simulation of various operating conditions. The first goal of the experimental program was to define the range of conditions over which the test unit should be tested. The second goal of the experimental studies was to determine the performance of the test unit under the defined conditions. All air conditioner performance data has been collected with air side instrumentation only. Experimental tests were performed using the test unit over a range of outdoor temperatures between 22.4°C (80°F) and 40.6°C (105°F) and indoor temperatures between 18.3°C (65°F) and 35°C (95°F). Analysis of the experimental data was performed by studying air conditioning parameters such as heat rejection rate qc, compressor power W, system capacity qe, and coefficient of performance COP. The analysis was accomplished with the variation of a boundary condition. The sensitivity analysis of experimental data gave expected results when compared to those shown by air conditioning units similar to our test unit.


2020 ◽  
Vol 1 (2) ◽  
pp. 37-43
Author(s):  
Ibrahim F. Abdulqadir ◽  
Badran M. Salim ◽  
Omar Shamdeen

The present work deal with the experimental study to retrofit the refrigerant R407c with the refrigerant R22 in the air conditioning unit at an ambient temperature range between 30-45°C. The main component of the experimental rig includes a window air conditioner with a refrigeration capacity of 2 Ton refrigeration that used refrigerant R22 as a working fluid in the experimental work. The refrigerant R22 is replaced with refrigerant R407C due to similar operation properties for the two refrigerants. The experimental results displayed the refrigeration effect and coefficient of performance COP of the R22 system are high as with those of the R407C system. The falls in the evaporator and condenser for the R407C system is lower than that of the R22 system. The temperature of discharge in the compressor for the system of refrigerant R22 is greater than that of the R407C system. Moreover, condensation temperature along the tube of the condenser is decreased with the increase of the distance for both refrigerants. The refrigerant R407C may be selected as a good alternate for R22 with an agreement difference in the two refrigerants’ performance. The system did not require replacement for any part of the AC unit.


2017 ◽  
Vol 21 (3) ◽  
pp. 1349-1358
Author(s):  
Mohideen Tharves ◽  
Nagachari Nethaji

This paper presents the performance analysis of a window air conditioner unit incorporated with wick less loop heat pipes (WLHP). The WLHP are located on the evaporator side of the air conditioning unit. The working medium for the WLHP is R134a refrigerant gas, an alternate refrigerant. The supply and return humidity of room air, the heat removal rat, and the coefficient of performance of the unit are analyzed for various ambient and room temperatures before and after incorporation of WLHP. The performance curves are drawn by comparing the power consumption and humidity collection rates for various room and ambient temperatures. The results show that coefficient of performance of the unit is improved by 18% to 20% after incorporation of WLHP due to pre-cooling of return air by WLHP, which reduces the thermal load on compressor. Similarly, the energy consumption is reduced by 20% to 25% due to higher thermostat setting and the humidity collection is improved by 35% due to pre-cooling effect of WLHP. The results are tabulated and conclusion drawn is presented based on the performance.


2021 ◽  
Vol 11 (4) ◽  
pp. 1710
Author(s):  
Jinwook Lee ◽  
Hyo-Sun Kim ◽  
Donik Ku ◽  
Jihun Lim ◽  
Minkyu Jung ◽  
...  

Membrane-based vacuum dehumidification technology is currently being actively studied. In most studies, the performance of the membrane-based systems is evaluated under the assumption that the membrane can achieve ideal separation, which results in ideal coefficient of performance (COP) values. However, the performance factors for membranes vary depending on the experimental conditions and measurement methods. Therefore, relevant values can only be calculated if the data are measured in an environment close to that of the application conditions. The cup measurement method is a simple method to measure the permeability, however, there are limitations regarding adding variables during the experiment. To overcome these limitations, a new experimental device was constructed that combines pressurized cell with the cup method. Using the device, the performance of polyethylene-amide-bonded dense membranes was evaluated under conditions where absolute pressure differentials occurred before and after the membrane, such as in air conditioner dehumidification systems.


Author(s):  
T. Kiatsiriroat ◽  
T. Euakit

In this paper the irreversibilities and second law efficiency of an automobile air-conditioner with R22/R124/R152a refrigerant blend have been carried out. The engine is 1,300 c.c. capacity and operated at different compressor speeds between 13–55 rps. The irreversibility at each component of the air-conditioner increases with higher compressor speed. Significant irreversibilities have been found at the condenser and the compressor. In the case of the cycle second law efficiency, the unit with 30% mass fraction of R22 shows better performance than those with 20 and 40% mass fraction.


2014 ◽  
Vol 960-961 ◽  
pp. 643-647
Author(s):  
Yan Sheng Xu

A stepped capillary tube consisting of two serially connected capillary tubes with different diameters is invented to replace the conventional expansion device. The mass flow rate of refrigerant R410A in stepped capillary tubes with different size were tested. The model of stepped capillary tube is proposed, and its numerical algorithm for tube length and mass flow rate is developed. The experimental results show that the performance comparing between stepped capillary tube system and capillary tube assembly system, the cooling capacity is reduced by 0.3%, the energy efficiency ratio (EER) is equal to each other, the heating capacity is increased by 0.3%, the coefficient of performance (COP) is decreased by 0.3%. That is to say, the performance index of the two kinds of throttle mechanism is almost identical. It indicates that the stepped capillary tube can replace the capillary tube assembly in the R410A heat pump type air conditioner absolutely. The model is validated with experimental data, and the results show that the model can be used for sizing and rating stepped capillary tube.


2008 ◽  
Vol 74 (748) ◽  
pp. 2552-2559 ◽  
Author(s):  
Yasuhiko SAKAI ◽  
Takaaki KATO ◽  
Yuu MORIGUCHI ◽  
Masaharu SAKAI ◽  
Kouji ITO ◽  
...  

2021 ◽  
Vol 4 ◽  
pp. 133-139
Author(s):  
Rikhard Ufie ◽  
Cendy S. Tupamahu ◽  
Sefnath J. E. Sarwuna ◽  
Jufraet Frans

Refrigerant R-22 is a substance that destroys the ozone layer, so that in the field of air conditioning it has begun to be replaced, among others with refrigerants R-32 and R-410a, and also R-290. Through this research, we want to know how much Coefficient of Performance (COP) and Refrigeration Capacity (Qe) can be produced for the four types of refrigerants. The study was carried out theoretically for the working conditions of the vapor compression cycle with an evaporation temperature (Tevap) of 0, -5, and -10oC, a further heated refrigerant temperature (ΔTSH) of 5 oC, a condensation temperature (Tkond) of 45 oC and a low-cold refrigerant temperature. (ΔTSC) 10 oC and compression power of 1 PK . The results of the study show that the Coefficient of Performance (COP) in the use of R-22 and R-290 is higher than the use of R-32 and R-410a, which are 4,920 respectively; 4,891; 4.690 and 4.409 when working at an evaporation temperature of 0 oC; 4.260; 4,234; 4.060 and 3.812 when working at an evaporation temperature of -5 oC; and amounted to 3,730; 3,685; 3,550 and 3,324 if working at an evaporation temperature of -10 oC. Based on the size of the COP, if this installation works with a compression power of 1 PK, then the cooling capacity of the R-22 and R-290 is higher than the R-32 and R-410a, which are 3,617 respectively. kW; 3,597 kW; 3,449 kW and 3,243 kW. If working at an evaporation temperature of 0 oC; 3.133 kW; 3.114 kW; 2,986 kW and 2,804 kW if working at an evaporation temperature of -5 oC; and 2,741 kW; 2,710 kW; 2,611 kW and 2,445 kW if working at an evaporation temperature of -10oC.


Metrologiya ◽  
2020 ◽  
pp. 48-62
Author(s):  
Vladimir A. Larionov

Existing methods of metrological self-monitoring of measuring sensors for temperature and pressure of technological industries are considered. The analysis of methods of metrological self-checking of strain gauge pressure sensors is carried out. Method is proposed based on measuring the supply voltage and voltage on the measuring diagonal of the bridge. The temperature of the strain gauge bridge is determined using a semiconductor thermistor installed near the bridge. This allows you to adjust the measured value of the total resistance of the bridge from the temperature of the bridge. With aging and exposure to external conditions, a change in the overall resistance of the bridge can be used to judge the error of the sensor. An experimental sample of the sensor was made. The failure of the strain gage bridge is simulated by parallel connection of an additional resistor to one of the shoulders of the bridge. Experimental studies have shown that modern technical means make it possible to assess the effect of changes in the total bridge resistance on the sensor error.