Effects of Airflow Velocity and Droplet Diameter on the Secondary Breakup Characteristics

AIAA Journal ◽  
2021 ◽  
pp. 1-9
Author(s):  
Wanli Zhu ◽  
Ningbo Zhao ◽  
Xiongbin Jia ◽  
Chengwen Sun ◽  
Hongtao Zheng
Author(s):  
Daisuke Ito ◽  
Susumu Nakano ◽  
yu Matsuzaki ◽  
Yoichi Takeda

Abstract Droplets generated at trailing edges of low-pressure steam turbines strike the leading edge of moving blades, resulting in severe damage by erosion. In this study, water film flows on a plate set in a parallel airflow and breakup patterns are observed and measured to investigate the breakup behavior of the water film at the plate edge and the effect of the plate edge thickness. Profiles of frequency distribution of the droplet diameters exhibit on approximately linear in a semilog graph. The gradient of those distributions becomes steeper when the air flow velocity increases. Coarse droplets are generated from the deformation of ligaments, as shown in the end stage of a sheet-type breakup, and will result in a secondary breakup. Meanwhile fine droplets whose diameters are similar to the critical diameter remain in the high airflow velocity region; they are assumed to contribute significantly to erosion damage. The plate edge thickness does not affect the frequency distributions of the droplet diameter and Sauter mean diameter. However, it affects the intermittency of discharge water. The discharged water period becomes longer when the plate edge thickness increases. This discharged water frequency is smaller than the wave frequency of the water film flow on the plate when the airflow velocity is high. Based on an experiment involving the highest airflow velocity, the discharged water frequency is similar to that generated by a general turbine rotation speed.


2018 ◽  
Vol 1 (1) ◽  
pp. 142-150
Author(s):  
Murat Tunc ◽  
Ayse Nur Esen ◽  
Doruk Sen ◽  
Ahmet Karakas

A theoretical post-dryout heat transfer model is developed for two-phase dispersed flow, one-dimensional vertical pipe in a post-CHF regime. Because of the presence of average droplet diameter lower bound in a two-phase sparse flow. Droplet diameter is also calculated. Obtained results are compared with experimental values. Experimental data is used two-phase flow steam-water in VVER-1200, reactor coolant system, reactor operating pressure is 16.2 MPa. On heater rod surface, dryout was detected as a result of jumping increase of the heater rod surface temperature. Results obtained display lower droplet dimensions than the experimentally obtained values.


Author(s):  
Arundhati Bhattacharyya ◽  
M Bajpai

Ketoconazole is an imidazole antifungal drug belonging to the class II of Biopharmaceutic Classification System. Maintenance of gastric acidity is essential for adequate dissolution and absorption of ketoconazole. Concurrent administration of antacid and antiulcer preparations decreases the oral absorption of ketoconazole often causing therapeutic failure.  The aim of this study was to evaluate whether a self-emulsifying formulation of ketoconazole would be able to overcome the pH dependent dissolution and oral bioavailability. Self-emulsifying drug delivery system (SEDDS) was prepared after selecting the oil, surfactant and co-surfactant by solubility analysis. Optimum ratio of the components was finalized on the basis of drug content, self-emulsification and mean droplet diameter. The effect of pH on dissolution was studied in comparison to the pure drug. Oral bioavailability was determined in comparison to aqueous suspension in rats and the effect of co-administration of ranitidine hydrochloride solution and a commercially available liquid antacid preparation was studied. The optimized formulation containing 20% Capryol 90 and 40% each of Carbitol and Tween 80, exhibited 100% drug release regardless of the pH whereas the pure drug exhibited a highly pH dependent dissolution. The AUC0-24 resulted with oral administration of the SEDDS formulation was about 34%, 43% and 60% higher compared to the aqueous suspension when administered alone, administered with ranitidine and administered with antacid respectively. The results of the present study demonstrate that self-emulsifying formulations can be utilized for oral delivery of weakly basic drugs like ketoconazole which exhibit pH dependent dissolution.


Foods ◽  
2021 ◽  
Vol 10 (5) ◽  
pp. 949
Author(s):  
Maged Mohammed ◽  
Nashi Alqahtani ◽  
Hamadttu El-Shafie

Dates are subjected to postharvest losses in quality and quantity caused by water loss, fermentation, insect infestation, and microbial spoilage during storage. Cold storage is the main element in the postharvest quality management used for fruit preservation. Although cold storage is used for dates, precision control of the relative humidity (RH) using ultrasonic applications is not used thus far, or it is applied to other fruits on a small scale. Therefore, we designed and constructed an ultrasonic humidifier (DUH) for RH control in the cold storage room (CSR) of dates. The optimum air velocity of 3 m s−1 at the outlets of the DUH ducts produced a mist amount of 6.8 kg h-1 with an average droplet diameter of 4.26 ± 1.43 µm at the applied voltage of 48 V and frequency of 2600 kHz of the transducers. The experimental validation was carried out by comparing a CSR controlled with the DUH with two conventional CSRs. The three tested CSRs were similar in dimensions, cooling system, and amount of stored dates. The time required for cooling 800 kg of dates in the controlled CSR from 25 °C to the target temperature of 5 °C was approximately 48 h. The DUH precisely controlled the RH at the maximum RH set point of 80% in the tested CSR at 5 °C. The controlled RH at 80% has a positive impact on the physicochemical characteristics of the stored dates. It significantly reduced the weight loss of the fruits and preserved fruit mass, moisture content, water activity, firmness, and color parameters. However, no significant effect was observed on fruit dimensions, sphericity, and aspect ratio. The microbial loads of mesophilic aerobic bacteria, molds, and yeasts fell within the acceptable limits in all tested CSRs. Both stored date fruits and artificially infested dates showed no signs of insect activity in the controlled CSR at the temperature of 5 °C and RH of 80%. The DUH proved to be a promising technology for postharvest quality management for dates during cold storage.


Author(s):  
Lu Yang ◽  
Qun Zheng ◽  
Aqiang Lin

Turbofan engine compressor is most severely threatened by the entry of liquid water during flight descent. This study aims to deeply understand the fluctuations of compressor performance parameters caused by water ingestion through frequency spectrum analysis. The water content and droplet diameter distribution are determined based on the real heavy rain environment. Results reveal that most of the droplets actually entering the core compressor have a particle size of less than 100 μm. In addition, the formation and motion of water film plays a critical role in affecting the fluctuation characteristics. Water ingestion deteriorates the compression performance and aggravates the unsteady fluctuations of the fan. However, the performance of the core compressor is less affected by water ingestion, but their fluctuations are still exacerbated. For some important parameters, such as inlet mass flow rate, total pressure ratio, total temperature ratio, compression work and efficiency, their main frequency of fluctuation are switched from the original blade passing frequency to the rotor passing frequency, and their amplitudes are correspondingly amplified to varying degrees. These phenomena can be observed in both the fluctuations of the fan and core compressor. Moreover, the operating point of them will be in the long-period and large-amplitude fluctuations, which leads them experiences the non-optimal state for a long time and threatens their operating stability.