Nonlinear control of rotating stall using axisymmetric bleed with continuous air injection on a low-speed, single stage, axial compressor

Author(s):  
Simon Yeung ◽  
Richard Murray ◽  
Simon Yeung ◽  
Richard Murray
Author(s):  
Alexander K. Simpson ◽  
John P. Longley

There are two established mechanisms, spike and modal inception, by which rotating stall is initiated in an axial flow compressor. Whilst the “Critical incidence hypothesis” and the “Zero slope criterion” are useful ideas in explaining the different stability boundaries for spikes and modes they do not provide the designer with a predictive tool. A detailed experimental investigation utilising a single-stage low-speed compressor is presented in which the aerodynamic environment of a rotor blade row is changed (rotor geometry is held fixed) so that it exhibited both spike and modal inception upon throttling into stall. The dominant mechanism of stall inception was found to be dependent on both the inlet flowfield and the downstream stator. The measurements are analysed and show that the meridional acceleration across the tip region of the rotor influences the mechanism by which rotating stall is incepted. This research is presented as a contribution towards the prediction of the stall inception mechanism.


Author(s):  
Asif Khalak ◽  
Richard M. Murray

This paper presents an experimental investigation of the effects of air injection on the rotating stall instability in a low speed axial compressor. Two experiments concerning air injection were tried. The first experiment used a continuous forcing perpendicular to the flow in the same or opposite direction of the tip velocity. The results show a dramatic difference between the two directions, with opposite direction forcing causing a significant increase in performance, and same direction forcing causing a significant decrease in performance. This result contradicts the Emmons stall propagation model. The second experiment investigated the differences with respect to different frequencies of air injection, with the injector pointed at the fan, parallel to the flow. We found that the change in the compressor characteristic in the unstalled region was highly dependent upon the forcing frequency with the maximum change occurring near the frequency of stall.


Author(s):  
Byeung Jun Lim ◽  
Tae Choon Park ◽  
Young Seok Kang

In this study, characteristics of stall inception in a single-stage transonic axial compressor with circumferential grooves casing treatment were investigated experimentally. Additionally, the characteristic of increasing irregularity in the pressure inside circumferential grooves as the compressor approaches the stall limit was applied to the stall warning method. Spike-type rotating stall was observed in the single-stage transonic axial compressor with smooth casing. When circumferential grooves were applied, the stall inception was suppressed and the operating point of the compressor moved to lower flow rate than the stall limit. A spike-like disturbance was developed into a rotating stall cell and then the Helmholtz perturbation was overlapped on it at N = 80%. At N = 70 %, the Helmholtz perturbation was observed first and the amplitude of the wave gradually increased as mass flow rate decreased. At N = 60%, spike type stall inceptions were observed intermittently and then developed into continuous rotating stall at lower mass flow rate. Pressure measured at the bottom of circumferential grooves showed that the level of irregularity of pressure increased as flow rate decreased. Based on the characteristic of increasing irregularity of the pressure signals inside the circumferential grooves as stall approaches, an autocorrelation technique was applied to the stall warning. This technique could be used to provide warning against stall and estimate real-time stall margins in compressors with casing treatments.


Author(s):  
Ali Arshad ◽  
Qiushi Li ◽  
Simin Li ◽  
Tianyu Pan

Experimental investigations of the effect of inlet blade loading on the rotating stall inception process are carried out on a single-stage low-speed axial compressor. Temporal pressure signals from the six high response pressure transducers are used for the analysis. Pressure variations at the hub are especially recorded during the stall inception process. Inlet blade loading is altered by installing metallic meshed distortion screens at the rotor upstream. Three sets of experiments are performed for the comparison of results, i.e. uniform inlet flow, tip, and hub distortions, respectively. Regardless of the type of distortion introduced to the inflow, the compressor undergoes a performance drop, which is more severe in the hub distortion case. Under the uniform inlet flow condition, stall inception is caused by the modal type disturbance while the stall precursor switched to spike type due to the highly loaded blade tip. In the presence of high blade loading at the hub, spike disappeared and the compressor once again witnessed a modal type disturbance. Hub pressure fluctuations are observed throughout the process when the stall is caused by a modal wave while no disturbance is noticed at the hub in spike type stall inception. It is believed that the hub flow separation contributes to the modal type of stall inception phenomenon. Results are also supported by the recently developed signal processing techniques for the stall inception study.


Author(s):  
Matthias Rolfes ◽  
Martin Lange ◽  
Konrad Vogeler ◽  
Ronald Mailach

The demand of increasing pressure ratios for modern high pressure compressors leads to decreasing blade heights in the last stages. As tip clearances cannot be reduced to any amount and minimum values might be necessary for safety reasons, the tip clearance ratios of the last stages can reach values notably higher than current norms. This can be intensified by a compressor running in transient operations where thermal differences can lead to further growing clearances. For decades, the detrimental effects of large clearances on an axial compressor’s operating range and efficiency are known and investigated. The ability of circumferential casing grooves in the rotor casing to improve the compressor’s operating range has also been in the focus of research for many years. Their simplicity and ease of installation are one reason for their continuing popularity nowadays, where advanced methods to increase the operating range of an axial compressor are known. In a previous paper [1], three different circumferential groove casing treatments were investigated in a single stage environment in the Low Speed Axial Research Compressor at TU Dresden. One of these grooves was able to notably improve the operating range and the efficiency of the single stage compressor at very large rotor tip clearances (5% of chord length). In this paper, the results of tests with this particular groove type in a three stage environment in the Low Speed Axial Research Compressor are presented. Two different rotor tip clearance sizes of 1.2% and 5% of tip chord length were investigated. At the small tip clearance, the grooves are almost neutral. Only small reductions in total pressure ratio and efficiency compared to the solid wall can be observed. If the compressor runs with large tip clearances it notably benefits from the casing grooves. Both, total pressure and efficiency can be improved by the grooves in a similar extent as in single stage tests. Five-hole probe measurements and unsteady wall pressure measurements show the influence of the groove on the flow field. With the help of numerical investigations the different behavior of the grooves at the two tip clearance sizes will be discussed.


Author(s):  
M Künzelmann ◽  
R Urban ◽  
R Mailach ◽  
K Vogeler

The stable operating range of axial compressors is limited by the onset of rotating stall and surge. Mass injection upstream of the tip of an axial compressor rotor is a stability enhancement approach which can be effective in suppressing stall in tip-critical rotors, and thus increasing the operating range of compressors. In this article, investigations on active flow control related to the rotor tip gap sensitivity are discussed. The experiments were performed in a 1.5-stage low-speed research compressor. Measurements at part speed (80 per cent) and full speed (100 per cent) with varying injection rates are discussed. These tests were performed for two rotor tip clearances of 1.3 per cent and 4.3 per cent of rotor blade tip chord. Results on the compressor map, the flow field as well as transient measurements to identify the stall inception are discussed. Supplementary, the numerical results are compared to the experiments based on the configuration with the greatest benefit in operating range enhancement.


Author(s):  
Masahiro Inoue ◽  
Motoo Kuroumaru ◽  
Shinichi Yoshida ◽  
Takahiro Minami ◽  
Kazutoyo Yamada ◽  
...  

Effect of the tip clearance on the transient process of rotating stall evolution has been studied experimentally in a low-speed axial compressor stage with various stator-rotor gaps. In the previous authors’ experiments for the small tip clearance, the stall evolution process of the rotor was sensitive to the gaps between the blade rows. For the large tip clearance, however, little difference is observed in the evolution processes independently of the blade row gap. In the first half process, it is characterized by gradual reduction of overall pressure-rise with flow rate decreasing, and the number of short length-scale disturbances is increasing with their amplitude increasing. In the latter half a long length-scale disturbance develops rapidly to result in deep stall. Just before the stall inception the spectral power density of the casing wall pressure reveals the existence of rotating disturbances with broadband high frequency near a quarter of the blade passing frequency. This is caused by the short length-scale disturbances occurring intermittently. A flow model is presented to explain mechanisms of the rotating short length-scale disturbance, which includes a tornado-like separation vortex and tip-leakage vortex breakdown. The model is supported by a result of a numerical unsteady flow simulation.


1998 ◽  
Vol 120 (4) ◽  
pp. 625-636 ◽  
Author(s):  
H. J. Weigl ◽  
J. D. Paduano ◽  
L. G. Fre´chette ◽  
A. H. Epstein ◽  
E. M. Greitzer ◽  
...  

Rotating stall and surge have been stabilized in a transonic single-stage axial compressor using active feedback control. The control strategy is to sense upstream wall static pressure patterns and feed back the signal to an annular array of twelve separately modulated air injectors. At tip relative Mach numbers of 1.0 and 1.5 the control achieved 11 and 3.5 percent reductions in stalling mass flow, respectively, with injection adding 3.6 percent of the design compressor mass flow. The aerodynamic effects of the injection have also been examined. At a tip Mach number, Mtip, of 1.0, the stall inception dynamics and effective active control strategies are similar to results for low-speed axial compressors. The range extension was achieved by individually damping the first and second spatial harmonics of the prestall perturbations using constant gain feedback. At a Mtip of 1.5 (design rotor speed), the prestall dynamics are different than at the lower speed. Both one-dimensional (surge) and two-dimensional (rotating stall) perturbations needed to be stabilized to increase the compressor operating range. At design speed, the instability was initiated by approximately ten rotor revolutions of rotating stall followed by classic surge cycles. In accord with the results from a compressible stall inception analysis, the zeroth, first, and second spatial harmonics each include more than one lightly damped mode, which can grow into the large amplitude instability. Forced response testing identified several modes traveling up to 150 percent of rotor speed for the first three spatial harmonics; simple constant gain control cannot damp all of these modes and thus cannot stabilize the compressor at this speed. A dynamic, model-based robust controller was therefore used to stabilize the multiple modes that comprise the first three harmonic perturbations in this transonic region of operation.


Sign in / Sign up

Export Citation Format

Share Document