Detection of flow condensation in hypersonic facilities using static pressure probes and Rayleigh scattering techniques.

2022 ◽  
Author(s):  
Erik M. Hoberg ◽  
Thomas J. Juliano ◽  
Guillaume Grossir
1979 ◽  
Vol 40 (C2) ◽  
pp. C2-140-C2-141 ◽  
Author(s):  
F. M. Wagner ◽  
F. J. Litterst ◽  
G. M. Kalvius
Keyword(s):  

Author(s):  
Fremmy Raymond Agustinus

Desain penyejuk udara juga dapat diterapkan di bidang kesehatan, dengan standar Cleanroom dapat diperoleh suhu, kelembaban, kenyamanan dan kebersihan yang dibutuhkan untuk ruang steril (ruang bedah). Perancangan pendingin udara dalam hal ini dilakukan dengan menentukan beban pendinginan yang diperlukan untuk ruang steril (ruang bedah), kemudian menentukan ukuran ducting, jalur ducting, dan jumlah penggunaan ducting. Desain ini menggabungkan unit split saluran yang dimodifikasi, kipas booster, filter pra, filter medium, dan filter HEPA dengan menggunakan saluran aluminium preinsulated sebagai saluran udara. Desain dilakukan dengan menggunakan perangkat lunak AutoCAD 2012, Design Tools Duct Sizer, dan Microsoft Excel. Dari hasil perhitungan dan desain didapatkan kebutuhan kapasitas 3 ruang bedah yaitu ducted ducted 100.000 BTUH sebanyak 3 unit, booster fan 3.3 - 4 Di WG sebanyak 3 unit, pre filter 24 "x 24" x 2 "6 set, filter menengah 610 x 610 x 290 mm 6 set, dan filter HEPA 1220 x 610 x 70 mm 12. Untuk ruang steril, tekanan statis yang dihasilkan oleh unit pendingin harus lebih besar daripada tekanan statis yang dihasilkan dari unit yang ada. di ruang semi steril. Dengan kata lain, ruang steril harus memiliki tekanan positif terhadap ruang semi steril. Hal ini dimaksudkan agar udara di ruang semi steril tidak masuk ke ruang steril ketika pintu antar ruangan dibuka. Desain dan perhitungan ruang bedah, suhu nyata yang diperoleh adalah 23 ° C ± 2 ° C dan kelembaban relatif yang diperoleh adalah 60% ± 2%.   Air conditioning design can also be applied in the health field, with cleanroom standard can be obtained temperature, humidity, comfort and hygiene needed for sterile room (surgical room). The design of air conditioning in this case is done by determining the cooling load required for the sterile room (surgical room), then determining the ducting size, ducting path, and the amount of ducting usage. This design combines modified ducted split unit, booster fan, pre filter, medium filter, and HEPA filter by using preinsulated aluminum duct as an air passage. The design is done by using AutoCAD 2012 software, Design Tools Duct Sizer, and Microsoft Excel. From the calculation and design result obtained the capacity requirement of 3 surgical room that is split ducted 100.000 BTUH as many as 3 units, booster fan 3.3 - 4 In WG as many as 3 units, pre filter 24"x 24" x 2" 6 sets, medium filter 610 x 610 x 290 mm 6 sets, and HEPA filter 1220 x 610 x 70 mm 12 sets. For the sterile room, the static pressure generated by the cooling unit shall be larger than the static pressure generated from the unit present in the semi sterile room. In other words, the sterile room must have positive pressure to the semi sterile room. It is intended that the air in the semi sterile room does not enter into the sterile room when the door between room opened. In this surgical room design and calculation, real temperature obtained is 23 °C ± 2 °C and the relative moisture obtained is 60% ± 2%.


1986 ◽  
Vol 84 ◽  
Author(s):  
M.D. Merz ◽  
F. Gerber ◽  
R. Wang

AbstractThe Materials Characterization Center (MCC) at Pacific Northwest Lab- oratory is performing three kinds of corrosion tests for the Basalt Waste Isolation Project (BWIP) to establish the interlaboratory reproducibility and uncertainty of corrosion rates of container materials for high-level nuclear waste. The three types of corrosion tests were selected to address two distinct conditions that are expected in a repository constructed in basalt. An air/steam test is designed to address corrosion during the operational period and static pressure vessel and flowby tests are designed to address corrosion under conditions that bound the condi ring the post-closure period of the repository.The results of tests at reference testing conditions, which were defined to facilitate interlaboratory comparison of data, are presented. Data are reported for the BWIP/MCC-105.5 Air/Steam Test, BWIP/MCC-105.1 Static Pressure Vessel, and BWIP/MC-105.4 Flowby Test. In those cases where data are available from a second laboratory, a statistical analysis of interlaboratory results is reported and expected confidence intervals for mean corrosion rates are given. Other statistical treatment of data include analyses of the effects of vessel-to-vessel variations, test capsule variations for the flowby test, and oven-to-oven variations for air/steam tests.


Author(s):  
Chun-Wei Yao ◽  
Jorge L. Alvarado ◽  
Charles P. Marsh ◽  
Barclay G. Jones ◽  
Michael K. Collins

2020 ◽  
Vol 5 (1) ◽  
pp. 37-41
Author(s):  
Ardit Gjeta ◽  
Lorenc Malka

In this paper, the effect of the outlet surface area of the spiral casing on the performance of a centrifugal fan was investigated using open source CFD software OpenFOAM [1]. An automized loop with RANS and data post-processing is set up using Matlab, for allowing a large number of parameter variations. The effect was analyzed as a function of total pressure loss and static pressure recovery coefficient and on total efficiency as well.


Sign in / Sign up

Export Citation Format

Share Document