scholarly journals Equivalent Model of Jump Flushing EDM. (1st Report). Proposal of a Model Represented by Electric Circuit.

1992 ◽  
Vol 26 (51) ◽  
pp. 39-49
Author(s):  
Masamitsu TSUCHIYA ◽  
Tsutomu KANEKO ◽  
Yasuhiro ABE ◽  
Seiji SATO
2013 ◽  
Vol 08 (01n02) ◽  
pp. 21-32 ◽  
Author(s):  
B. I. MORSHED ◽  
M. SHAMS ◽  
T. MUSSIVAND

Electroporation is the formation of reversible pores in cell membranes under a brief pulse of high electric field. Dynamics of pore formation during electroporation suggests that the transmembrane potential would settle approximately at the threshold transmembrane potential and the transmembrane resistance would decrease significantly from the state of relaxation. The current electric circuit equivalent models for electroporation containing time-invariant, static and passive components are unable to capture the pore dynamics. A biophysically-inspired electric circuit equivalent model containing dynamic components for membrane pores has been derived using biological parameters. The model contains a voltage-controlled resistor driven by a two-stage cascaded integrator that is activated through a voltage-gated switch. Simulation results with the derived model showed higher accuracy compared to a commonly used model, where the transmembrane resistance decreased million-fold at the onset of electroporation and the transmembrane potential settled at 99.5% of the critical transmembrane potential, thus enabling improved dynamic behavior modeling ability of the pores in electroporation. The derived model allows fast and reliable analysis of this biophysical phenomenon and potentially aids in optimization of various parameters involved in electroporation.


1978 ◽  
Vol 39 (02) ◽  
pp. 455-465 ◽  
Author(s):  
Yvonne Stirling ◽  
D J Howarth ◽  
Marguerite Vickers ◽  
W R S North ◽  
T W Meade

SummaryTwo automated methods for two-stage factor VIII assays have been compared with one another, and evaluated in practice. The Depex method records the clotting time when an electric circuit is completed by the formation of a fibrin thread across a hook-type electrode; the Electra method is based on an optical density technique of clot detection. The two methods gave comparable results for measured levels of factor VIII when haemophilic or “normal” plasmas were assayed. Results from the two methods in practice also suggest that both are valid at low and “normal” factor VIII levels. The Electra method is also probably suitable for assays of concentrates; however, the Depex method appears to give falsely high values in these circumstances, and experimental findings suggest that the reason may be that increased viscosity due to the high fibrinogen levels in factor VIII concentrates causes premature closure of the circuit between the two ends of the Depex electrode. The main advantage of the Depex method is that, provided 3 or 4 machines are available, a given number of assays can be completed more quickly than on Electra. The main advantages of Electra are that it is probably subject to less laboratory error than Depex, and that it is suitable for assaying concentrates as well as haemophilic and “normal” plasmas.


2020 ◽  
Vol 86 (2) ◽  
pp. 44-53
Author(s):  
Yu. I. Dudarkov ◽  
M. V. Limonin

An engineering approach to estimation of the transverse shear stresses in layered composites is developed. The technique is based on the well-known D. I. Zhuravsky equation for shear stresses in an isotropic beam upon transverse bending. In general, application of this equation to a composite beam is incorrect due to the heterogeneity of the composite structure. According to the proposed method, at the first stage of its implementation, a transition to the equivalent model of a homogeneous beam is made, for which the Zhuravsky formula is valid. The transition is carried out by changing the shape of the cross section of the beam, provided that the bending stiffness and generalized elastic modulus remain the same. The calculated shear stresses in the equivalent beam are then converted to the stress values in the original composite beam from the equilibrium condition. The main equations and definitions of the method as well as the analytical equation for estimation of the transverse shear stress in a composite beam are presented. The method is verified by comparing the analytical solution and the results of the numerical solution of the problem by finite element method (FEM). It is shown that laminate stacking sequence has a significant impact both on the character and on the value of the transverse shear stress distribution. The limits of the applicability of the developed technique attributed to the conditions of the validity of the hypothesis of straight normal are considered. It is noted that under this hypothesis the shear stresses do not depend on the layer shear modulus, which explains the absence of this parameter in the obtained equation. The classical theory of laminate composites is based on the similar assumptions, which gives ground to use this equation for an approximate estimation of the transverse shear stresses in in a layered composite package.


Author(s):  
V. I. Sukhanov ◽  
A. B. Grabov

The article presents some features of thin-film magnetoresistive current sensors and detectors that was developed in JSC NPO IT for noncontact current control in electric circuit aviation and cosmic electronic apparatus.


Author(s):  
Sunny Katyara ◽  
Lukasz Staszewski ◽  
Faheem Akhtar Chachar

Background: Since the distribution networks are passive until Distributed Generation (DG) is not being installed into them, the stability issues occur in the distribution system after the integration of DG. Methods: In order to assure the simplicity during the calculations, many approximations have been proposed for finding the system’s parameters i.e. Voltage, active and reactive powers and load angle, more efficiently and accurately. This research presents an algorithm for finding the Norton’s equivalent model of distribution system with DG, considering from receiving end. Norton’s model of distribution system can be determined either from its complete configuration or through an algorithm using system’s voltage and current profiles. The algorithm involves the determination of derivative of apparent power against the current (dS/dIL) of the system. Results: This work also verifies the accuracy of proposed algorithm according to the relative variations in the phase angle of system’s impedance. This research also considers the varying states of distribution system due to switching in and out of DG and therefore Norton’s model needs to be updated accordingly. Conclusion: The efficacy of the proposed algorithm is verified through MATLAB simulation results under two scenarios, (i) normal condition and (ii) faulty condition. During normal condition, the stability factor near to 1 and change in dS/dIL was near to 0 while during fault condition, the stability factor was higher than 1 and the value of dS/dIL was away from 0.


2020 ◽  
Vol 96 (3s) ◽  
pp. 295-299
Author(s):  
М.М. Гурарий ◽  
М.М. Жаров ◽  
Л.П. Ионов ◽  
И.И. Мухин ◽  
С.Г. Русаков ◽  
...  

В работе рассмотрены проблемы анализа схем ФАПЧ с учетом наличия неидеальностей в схеме частотно-фазового детектора с токовым ключом. Для снижения затрат на моделирование предложено использовать эквивалентную электрическую схему, содержащую полную принципиальную схему ЧФД и схемные эквиваленты макромоделей остальных блоков ФАПЧ. The paper considers the problems of analyzing the PLL circuit taking into account the presence of nonidealities in the phase-frequency detector with a current key. To reduce the simulation efforts, it has been proposed to apply an equivalent electric circuit containing the complete schematic diagram of the PFD and circuit equivalents of the macromodels of other PLL blocks.


Author(s):  
Aleksandr S. Serebryakov ◽  
Vladimir L. Osokin ◽  
Sergey A. Kapustkin

The article describes main provisions and relations for calculating short-circuit currents and phase currents in a three-phase traction transformer with a star-triangle-11 connection of windings, which feeds two single-phase loads in AC traction networks with a nominal voltage of 25 kilovolts. These transformers provide power to the enterprises of the agro-industrial complex located along the railway line. (Research purpose) The research purpose is in substantiating theoretical equations for digital intelligent relay protection in two-phase short circuits. (Materials and methods) It was found that since the sum of instantaneous currents in each phase is zero, each phase of the transformer works independently. We found that this significantly simplifies the task of analyzing processes with a two-phase short circuit. In this case, the problem of calculating short-circuit currents in the traction network can be simplified by reducing it to the calculation of an ordinary electric circuit with three unknown currents. (Results and discussion) The article describes equations for calculating short-circuit resistances for one phase of the transformer when connecting the secondary winding as a star or a triangle. The currents in the phases of the transformer winding at short circuit for the star-triangle-11 and star-star-with-ground schemes are compared. It was found that when calculating short-circuit currents, there is no need to convert the secondary winding of the traction transformer from a triangle to a star. (Conclusions) It was found that the results of the research can be used in the transition of relay protection systems from electromagnetic relays to modern high-speed digital devices, which will increase the operational reliability of power supply systems for traction and non-traction power consumers.


Energies ◽  
2021 ◽  
Vol 14 (5) ◽  
pp. 1262
Author(s):  
Alessandro Mingotti ◽  
Federica Costa ◽  
Lorenzo Peretto ◽  
Roberto Tinarelli ◽  
Paolo Mazza

Stray capacitances (SCs) are a serious issue in high-voltage (HV) applications. Their presence can alter the circuit or the operation of a device, resulting in wrong or even disastrous consequences. To this purpose, in this work, we describe the modeling of SCs in HV capacitive dividers. Such modeling does not rely on finite element analysis or complicated geometries; instead, it starts from an equivalent circuit of a conventional measurement setup described by the standard IEC 61869-11. Once the equivalent model including the SCs is found, closed expressions of the SCs are derived starting from the ratio error definition. Afterwards, they are validated in a simulation environment by implementing various circuit configurations. The results demonstrate the expressions applicability and effectiveness; hence, thanks to their simplicity, they can be implemented by system operators, researchers, and manufacturers avoiding the use of complicated methods and technologies.


Sign in / Sign up

Export Citation Format

Share Document