scholarly journals ENHANCING THE EFFICIENCY OF INDOOR LOCAL VENTILATION USING CROSS-FLOW FANS: CASE STUDY FOR A SMOKING CABIN

2015 ◽  
Vol 21 (3) ◽  
pp. 28-34
Author(s):  
ANDREI DRAGOMIRESCU ◽  
ADRIAN CIOCĂNEA

The paper presents an original solution for increasing air quality and reducing energy consumption of the local indoor ventilation by using cross-flow fans. The solution is a combination between the local exhaust ventilation (LEV) technique from industry, negative-pressure isolation rooms used in hospitals, and air curtains (AC) used for isolating of indoor/outdoor spaces. The solution provides a high air flow rate at low velocity due to the high value of the flow coefficient of the cross flow fans and, in the same time, allows modular setup according to local space geometry. A case study is proposed regarding the isolation of a smoking area where smell and airborne particles appear. A 3D numerical simulation was performed, in which one cross-flow fan with long axial length was considered. The optimum air flow rate and flow pattern was obtained in order to isolate the local space. The results show that a new approach for reducing sick building syndrome could be addressed by providing modular and local ventilation using cross-flow fans.

2016 ◽  
Vol 21 (3) ◽  
Author(s):  
DRAGOMIRESCU ANDREI ◽  
CIOCĂNEA ADRIAN

<p>The paper presents an original solution for increasing air quality and reducing energy consumption of the local indoor ventilation by using cross-flow fans. The solution is a combination between the local exhaust ventilation (LEV) technique from industry, negative-pressure isolation rooms used in hospitals, and air curtains (AC) used for isolating of indoor/outdoor spaces. The solution provides a high air flow rate at low velocity due to the high value of the flow coefficient of the cross flow fans and, in the same time, allows modular setup according to local space geometry. A case study is proposed regarding the isolation of a smoking area where smell and airborne particles appear. A 3D numerical simulation was performed, in which one cross-flow fan with long axial length was considered. The optimum air flow rate and flow pattern was obtained in order to isolate the local space. The results show that a new approach for reducing sick building syndrome could be addressed by providing modular and local ventilation using cross-flow fans.</p>


Energies ◽  
2018 ◽  
Vol 11 (12) ◽  
pp. 3374 ◽  
Author(s):  
Yugang Wang ◽  
Xiang Huang ◽  
Li Li

This paper presents a comparative study of the cross-flow regenerative heat and mass exchanger (HMX) and the conventional cross-flow HMX for indirect evaporative cooling (IEC) with numerical methods. The objective of this study is mainly to clarify the applicability of the two HMXs. The numerical model was built and validated by existing experimental data. The difference in heat and mass transfer between the two HMXs was revealed by analyzing the change of the temperature and moisture content of the air, and the influence of the main operating parameters on the cooling performance of the HMXs was analyzed. In the typical operating conditions, when the HMXs are used alone, the cooling performance of the regenerative HMX is better than that of the conventional HMX under low supply air flow rate. When the HMXs are used in the multistage evaporative cooling systems with high supply air flow rate, the conventional HMX is more suitable as the first stage of the system to pre-cool the supply air, while the regenerative HMX is more suitable as the second stage to re-cool the supply air.


Author(s):  
Danish Rahman ◽  
Ahmad Almomani ◽  
Ibrahim Hassan ◽  
Yasser Al-Hamidi ◽  
Aziz Rahman

This paper aimed to study two-phase flow under adiabatic conditions through the process of flow visualization. This was done through the use of a test section with a cross flow and a jet impingement (swirl jet). The flow regimes under different air-water flow rates were determined using a high-speed camera that recorded digital videos. For each of the flow rates the pressure differential between the inlet and the outlets were measured. Through the pressure drop it is proposed that the types of flow regimes may later be able to be predicted. Nine air-water flow rates were considered to collect data and generate a flow map for the impingement jet and cross flow. The major observed flow regimes within the crossflow and impingement jet followed the predicted trend with bubbly and plug flow in the former, and slug flow in the latter. It was further observed that increasing the air flow rate increased the likelihood of bubbly and plug flow in both the cross-flow and impingement jet. In the cross flow, a lower air flow rate resulted in bubbly flow while within the impingement jet, a lower air flow rate resulted in slug flow.


2021 ◽  
pp. 174425912098418
Author(s):  
Toivo Säwén ◽  
Martina Stockhaus ◽  
Carl-Eric Hagentoft ◽  
Nora Schjøth Bunkholt ◽  
Paula Wahlgren

Timber roof constructions are commonly ventilated through an air cavity beneath the roof sheathing in order to remove heat and moisture from the construction. The driving forces for this ventilation are wind pressure and thermal buoyancy. The wind driven ventilation has been studied extensively, while models for predicting buoyant flow are less developed. In the present study, a novel analytical model is presented to predict the air flow caused by thermal buoyancy in a ventilated roof construction. The model provides means to calculate the cavity Rayleigh number for the roof construction, which is then correlated with the air flow rate. The model predictions are compared to the results of an experimental and a numerical study examining the effect of different cavity designs and inclinations on the air flow rate in a ventilated roof subjected to varying heat loads. Over 80 different test set-ups, the analytical model was found to replicate both experimental and numerical results within an acceptable margin. The effect of an increased total roof height, air cavity height and solar heat load for a given construction is an increased air flow rate through the air cavity. On average, the analytical model predicts a 3% higher air flow rate than found in the numerical study, and a 20% lower air flow rate than found in the experimental study, for comparable test set-ups. The model provided can be used to predict the air flow rate in cavities of varying design, and to quantify the impact of suggested roof design changes. The result can be used as a basis for estimating the moisture safety of a roof construction.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Shahrbanoo Hamedi ◽  
M. Mehdi Afsahi ◽  
Ali Riahi-Madvar ◽  
Ali Mohebbi

AbstractThe main advantages of the dried enzymes are the lower cost of storage and longer time of preservation for industrial applications. In this study, the spouted bed dryer was utilized for drying the garden radish (Raphanus sativus L.) root extract as a cost-effective source of the peroxidase enzyme. The response surface methodology (RSM) was used to evaluate the individual and interactive effects of main parameters (the inlet air temperature (T) and the ratio of air flow rate to the minimum spouting air flow rate (Q)) on the residual enzyme activity (REA). The maximum REA of 38.7% was obtained at T = 50 °C and Q = 1.4. To investigate the drying effect on the catalytic activity, the optimum reaction conditions (pH and temperature), as well as kinetic parameters, were investigated for the fresh and dried enzyme extracts (FEE and DEE). The obtained results showed that the optimum pH of DEE was decreased by 12.3% compared to FEE, while the optimum temperature of DEE compared to FEE increased by a factor of 85.7%. Moreover, kinetic parameters, thermal-stability, and shelf life of the enzyme were considerably improved after drying by the spouted bed. Overall, the results confirmed that a spouted bed reactor can be used as a promising method for drying heat-sensitive materials such as peroxidase enzyme.


1979 ◽  
Vol 3 (6) ◽  
pp. 357-362
Author(s):  
H. C. Hewitt ◽  
E. I. Griggs

Author(s):  
Ari Kettunen ◽  
Timo Hyppa¨nen ◽  
Ari-Pekka Kirkinen ◽  
Esa Maikkola

The main objective of this study was to investigate the load change capability and effect of the individual control variables, such as fuel, primary air and secondary air flow rates, on the dynamics of large-scale CFB boilers. The dynamics of the CFB process were examined by dynamic process tests and by simulation studies. A multi-faceted set of transient process tests were performed at a commercial 235 MWe CFB unit. Fuel reactivity and interaction between gas flow rates, solid concentration profiles and heat transfer were studied by step changes of the following controllable variables: fuel feed rate, primary air flow rate, secondary air flow rate and primary to secondary air flow ratio. Load change performance was tested using two different types of tests: open and closed loop load changes. A tailored dynamic simulator for the CFB boiler was built and fine-tuned by determining the model parameters and by validating the models of each process component against measured process data of the transient test program. The know-how about the boiler dynamics obtained from the model analysis and the developed CFB simulator were utilized in designing the control systems of three new 262 MWe CFB units, which are now under construction. Further, the simulator was applied for the control system development and transient analysis of the supercritical OTU CFB boiler.


Sign in / Sign up

Export Citation Format

Share Document