ANALYTICAL APPROACH TO ESTIMATE THE AIR FLOW RATE IN THE BOUNDARY LAYER OF A HEATED FURNACE WALL

2008 ◽  
Vol 7 (3) ◽  
pp. 329-335
Author(s):  
Alina Adriana Minea ◽  
Adrian Dima
Author(s):  
Taiji Tanaka ◽  
Hyun Jin Park ◽  
Yuji Tasaka ◽  
Yuichi Murai

Abstract To investigate the development process of a void wave, spatio-temporal fluctuation of void fraction, we examined experimentally a turbulent boundary layer with bubble injections. The experiments performed on a flat bottom of 4-mlong transparent model ship towed in a tank of 100 m length with the speed of up to 3.00 m/s. In bubbles injection with constant air flow rate, void fluctuations with 4 Hz or 8 Hz appeared dependent on the towing speed. With periodically fluctuated air flow rate, artificial void waves were provided into the turbulent boundary layer and their frequency was maintained during the downstream propagation. The attenuation rate of the fluctuation evaluated using Fourier analysis of the wave took the minimum value at specific injection frequency conditions.


2003 ◽  
Vol 3 (5-6) ◽  
pp. 67-72
Author(s):  
S. Takizawa ◽  
T. Win

In order to evaluate effects of operational parameters on the removal efficiency of trichloroethylene and 1,1,1-trichloroethene from water, lab-scale experiments were conducted using a novel hollow-fibre gaspermeable membrane system, which has a very thin gas-permeable membrane held between microporous support membranes. The permeation rate of chlorinated hydrocarbons increased at higher temperature and water flow rate. On the other hand, the effects of the operational conditions in the permeate side were complex. When the permeate side was kept at low pressure without sweeping air (pervaporation), the removal efficiency of chlorinated hydrocarbon, as well as water permeation rate, was low probably due to lower level of membrane swelling on the permeate side. But when a very small amount of air was swept on the membrane (air perstripping) under a low pressure, it showed a higher efficiency than in any other conditions. Three factors affecting the permeation rate are: 1) reduction of diffusional boundary layer within the microporous support membrane, 2) air/vapour flow regime and short cutting, and 3) the extent of membrane swelling on the permeate side. A higher air flow, in general, reduces the diffusional boundary layer, but at the same time disrupts the flow regime, causes short cutting, and makes the membrane dryer. Due to these multiple effects on gas permeation, there is an optimum operational condition concerning the vacuum pressure and the air flow rate. Under the optimum operational condition, the residence time within the hollow-fibre membrane to achieve 99% removal of TCE was 5.25 minutes. The log (removal rate) was linearly correlated with the average hydraulic residence time within the membrane, and 1 mg/L of TCE can be reduced to 1 μg/L (99.9% removal).


2021 ◽  
pp. 174425912098418
Author(s):  
Toivo Säwén ◽  
Martina Stockhaus ◽  
Carl-Eric Hagentoft ◽  
Nora Schjøth Bunkholt ◽  
Paula Wahlgren

Timber roof constructions are commonly ventilated through an air cavity beneath the roof sheathing in order to remove heat and moisture from the construction. The driving forces for this ventilation are wind pressure and thermal buoyancy. The wind driven ventilation has been studied extensively, while models for predicting buoyant flow are less developed. In the present study, a novel analytical model is presented to predict the air flow caused by thermal buoyancy in a ventilated roof construction. The model provides means to calculate the cavity Rayleigh number for the roof construction, which is then correlated with the air flow rate. The model predictions are compared to the results of an experimental and a numerical study examining the effect of different cavity designs and inclinations on the air flow rate in a ventilated roof subjected to varying heat loads. Over 80 different test set-ups, the analytical model was found to replicate both experimental and numerical results within an acceptable margin. The effect of an increased total roof height, air cavity height and solar heat load for a given construction is an increased air flow rate through the air cavity. On average, the analytical model predicts a 3% higher air flow rate than found in the numerical study, and a 20% lower air flow rate than found in the experimental study, for comparable test set-ups. The model provided can be used to predict the air flow rate in cavities of varying design, and to quantify the impact of suggested roof design changes. The result can be used as a basis for estimating the moisture safety of a roof construction.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Shahrbanoo Hamedi ◽  
M. Mehdi Afsahi ◽  
Ali Riahi-Madvar ◽  
Ali Mohebbi

AbstractThe main advantages of the dried enzymes are the lower cost of storage and longer time of preservation for industrial applications. In this study, the spouted bed dryer was utilized for drying the garden radish (Raphanus sativus L.) root extract as a cost-effective source of the peroxidase enzyme. The response surface methodology (RSM) was used to evaluate the individual and interactive effects of main parameters (the inlet air temperature (T) and the ratio of air flow rate to the minimum spouting air flow rate (Q)) on the residual enzyme activity (REA). The maximum REA of 38.7% was obtained at T = 50 °C and Q = 1.4. To investigate the drying effect on the catalytic activity, the optimum reaction conditions (pH and temperature), as well as kinetic parameters, were investigated for the fresh and dried enzyme extracts (FEE and DEE). The obtained results showed that the optimum pH of DEE was decreased by 12.3% compared to FEE, while the optimum temperature of DEE compared to FEE increased by a factor of 85.7%. Moreover, kinetic parameters, thermal-stability, and shelf life of the enzyme were considerably improved after drying by the spouted bed. Overall, the results confirmed that a spouted bed reactor can be used as a promising method for drying heat-sensitive materials such as peroxidase enzyme.


1979 ◽  
Vol 3 (6) ◽  
pp. 357-362
Author(s):  
H. C. Hewitt ◽  
E. I. Griggs

Author(s):  
Ari Kettunen ◽  
Timo Hyppa¨nen ◽  
Ari-Pekka Kirkinen ◽  
Esa Maikkola

The main objective of this study was to investigate the load change capability and effect of the individual control variables, such as fuel, primary air and secondary air flow rates, on the dynamics of large-scale CFB boilers. The dynamics of the CFB process were examined by dynamic process tests and by simulation studies. A multi-faceted set of transient process tests were performed at a commercial 235 MWe CFB unit. Fuel reactivity and interaction between gas flow rates, solid concentration profiles and heat transfer were studied by step changes of the following controllable variables: fuel feed rate, primary air flow rate, secondary air flow rate and primary to secondary air flow ratio. Load change performance was tested using two different types of tests: open and closed loop load changes. A tailored dynamic simulator for the CFB boiler was built and fine-tuned by determining the model parameters and by validating the models of each process component against measured process data of the transient test program. The know-how about the boiler dynamics obtained from the model analysis and the developed CFB simulator were utilized in designing the control systems of three new 262 MWe CFB units, which are now under construction. Further, the simulator was applied for the control system development and transient analysis of the supercritical OTU CFB boiler.


Energies ◽  
2020 ◽  
Vol 14 (1) ◽  
pp. 167
Author(s):  
Hasan Alimoradi ◽  
Madjid Soltani ◽  
Pooriya Shahali ◽  
Farshad Moradi Kashkooli ◽  
Razieh Larizadeh ◽  
...  

In this study, a numerical and empirical scheme for increasing cooling tower performance is developed by combining the particle swarm optimization (PSO) algorithm with a neural network and considering the packing’s compaction as an effective factor for higher accuracies. An experimental setup is used to analyze the effects of packing compaction on the performance. The neural network is optimized by the PSO algorithm in order to predict the precise temperature difference, efficiency, and outlet temperature, which are functions of air flow rate, water flow rate, inlet water temperature, inlet air temperature, inlet air relative humidity, and packing compaction. The effects of water flow rate, air flow rate, inlet water temperature, and packing compaction on the performance are examined. A new empirical model for the cooling tower performance and efficiency is also developed. Finally, the optimized performance conditions of the cooling tower are obtained by the presented correlations. The results reveal that cooling tower efficiency is increased by increasing the air flow rate, water flow rate, and packing compaction.


Sign in / Sign up

Export Citation Format

Share Document