scholarly journals ANALISA LAJU PERPINDAHAN PANAS PADA KOLEKTOR SURYA TIPE PELAT DATAR DENGAN ABSORBER PASIR

2011 ◽  
Vol 1 (2) ◽  
Author(s):  
Made Wirawan ◽  
Rudy Sutanto

Solar energy constitute one of potential alternative energy to develop as a back up of energy. Especially for countries in khatulistiwa location belonging to Indonesia. For use solar energy needful collector that using absorber. Using sand as a absorber make up step for increase value and profit of sand, in a economics manner the price more cheap and easy to obtain than another absorber. The analysis use sand as a alternative absorber for solar collector did for understand rate of heat transfer to acceptanceof water. Dimention of collector are 560 mm x 310 mm with thick of sand absorber 10 mm and 1.2 mm for aluminum plate as a comparator. Observation did begin 10.00 am until 14.00 pm for the two of them in the weather clear sky. The rate of water in this research are 200 cc/min, 250 cc/min and 300 cc/mn for another dan at the same time. The result of analysis be obtained heat absortion by water for solar collector with aluminum absorber more large than sand absorber. The debit of water more and more large in the collector so absorb heat by water more large because incretion the mass flow rate of water (m  ). The heat losses in the solar collector aluminum absorber more than sand absorber.

2020 ◽  
Vol 13 (3) ◽  
pp. 206-221
Author(s):  
Vijayan Gopalsamy ◽  
Karunakaran Rajasekaran ◽  
Logesh Kamaraj ◽  
Siva Sivasaravanan ◽  
Metin Kok

Background: Aqueous-alumina nanofluid was prepared using magnetic stirrer and ultrasonication process. Then, the prepared nanofluid was subjected to flow through the unshielded receiver of the parabolic trough solar collector to investigate the performance of the nanofluid and the effects of the dimensionless parameter were determined. Methods: The experimental work has been divided into two sections. First, the nanofluid was prepared and tested for its morphology, dimensions, and sedimentation using X-Ray Diffraction and Raman shift method. Then, the nanofluids of various concentrations from 0 to 4.0% are used as heat transfer fluid in unshielded type collector. Finally, the effect of the dimensionless parameter on the performance was determined. Results: For the whole test period, depending upon the bulk mean temperature, the dimensionless parameters such as Re and Nu varied from 1098 to 4552 & 19.30 to 46.40 for air and 2150 to 7551 & 11.11 to 48.54 for nanofluid. The enhancement of thermal efficiency found for 0% and 4.0% nanoparticle concentrations was 32.84% for the mass flow rate of 0.02 kg/s and 13.26% for the mass flow rate of 0.06 kg/s. Conclusion: Re and Nu of air depend on air velocity and ambient temperature. Re increased with the mass flow rate and decreased with concentration. Heat loss occurred by convection mode of heat transfer. Heat transfer coefficient and global efficiency increased with increased mass flow rate and volume fraction. The thermal efficiency of both 0% and 4.0% concentrations became equal for increased mass flow rate. It has been proven that at high mass flow rates, the time available to absorb the heat energy from the receiver is insufficient.


2019 ◽  
Vol 141 (6) ◽  
Author(s):  
Muhammad Abid ◽  
Muhammad Sajid Khan ◽  
Tahir Abdul Hussain Ratlamwala

The concentration ratio of the parabolic dish solar collector (PDSC) is considered to be one of the highest among the concentrated solar power technologies (CSPs); therefore, such system is capable of generating more heat rate. The present paper focuses on the integration of the PDSC with the combined cycle (gas cycle as the toping cycle and steam cycle as the bottoming cycle) along with the utilization of waste heat from the power cycle to drive the single effect lithium bromide/water absorption cycle. Molten salt is used as a heat transfer fluid in the solar collector. The engineering equation solver (EES) is employed for the mathematical modeling and simulation of the solar integrated system. The various operating parameters (beam radiation, inlet and ambient temperatures of heat transfer fluid, mass flow rate of heat transfer fluid, evaporator temperature, and generator temperature) are varied to analyze their influence on the performance parameters (power output, overall energetic and exergetic efficiencies, outlet temperature of the receiver, and as coefficient of performance (COP) and exergy efficiencies) of the integrated system. The results show that the overall energy and exergy efficiencies are observed to be 39.9% and 42.95% at ambient temperature of 27 °C and solar irradiance of 1000 W/m2. The outlet temperature of the receiver is noticed to decrease from 1008 K to 528 K for an increase in the mass flow rate from 0.01 to 0.05 kg/s. The efficiency rate of the power plant is 38%, whereas COP of single effect absorption system is 0.84, and it will decrease from 0.87 to 0.79. However, the evaporator load is decreased to approximately 9.7% by increasing the generator temperature from 47 °C to 107 °C.


2010 ◽  
Vol 14 (1) ◽  
pp. 221-234 ◽  
Author(s):  
Rachid Saim ◽  
Said Abboudi ◽  
Boumédiene Benyoucef

The poor thermal exchange between the absorber and the fluid in the solar air flat plate collector, gives the bad performance and the mediocre thermal efficiency. The introduction of obstacles in the dynamic air vein of the solar collector in order to obtain a turbulent flow is a technique that improves the thermal exchange by convection between the air and the absorber. This article present a computational analysis on the turbulent flow and heat transfer in solar air collector with rectangular plate fins absorber and baffles which are arranged on the bottom and top channel walls in a periodically staggered way. To this end we solved numerically, by the finite volumes method, the conservation equations of mass, momentum and energy. The low Reynolds number k-? model was adopted for the taking into account of turbulence. The velocity and pressure terms of momentum equations are solved by the SIMPLE algorithm. The parameters studied include the entrance mass flow rate of air. The influence of the mass flow rate of air on the axial velocity and the efficiency of upward type baffled solar air heaters have been investigated numerically. The results show that the flow and the heat transfer characteristics are strongly dependent on mass-flow rate of air and the presence and/or the absence of the baffles and fins in the solar collector. It was observed that increasing the Reynolds number will increase the efficiency of the solar panel, as expected.


Author(s):  
Gaowen Liu ◽  
Zhao Lei ◽  
Aqiang Lin ◽  
Qing Feng ◽  
Yan Chen

The pre-swirl system is of great importance for temperature drop and cooling air supply. This study aims to investigate the influencing mechanism of heat transfer, nonuniform thermodynamic characteristics, and cooling air supply sensitivity in a pre-swirl system by the application of the flow control method of the pre-swirl nozzle. A novel test rig was proposed to actively control the supplied cooling air mass flow rate by three adjustable pre-swirl nozzles. Then, the transient problem of the pre-swirl system was numerically conducted by comparison with 60°, 120°, and 180° rotating disk cavity cases, which were verified with the experiment results. Results show that the partial nozzle closure will aggravate the fluctuation of air supply mass flow rate and temperature. When three parts of nozzles are closed evenly at 120° in the circumferential direction, the maximum value of the nonuniformity coefficient of air supply mass flow rate changes to 3.1% and that of temperature changes to 0.25%. When six parts of nozzles are closed evenly at 60° in the circumferential direction, the maximum nonuniformity coefficient of air supply mass flow rate changes to 1.4% and that of temperature changes to 0.20%. However, different partial nozzle closure modes have little effect on the average air supply parameters. Closing 14.3% of the nozzle area will reduce the air supply mass flow rate by 9.9% and the average air supply temperature by about 1 K.


2003 ◽  
Vol 125 (1) ◽  
pp. 104-113 ◽  
Author(s):  
Chang-Yuan Liu ◽  
Ying-Huei Hung

Both experimental and theoretical investigations on the heat transfer and flow friction characteristics of compact cold plates have been performed. From the results, the local and average temperature rises on the cold plate surface increase with increasing chip heat flux or decreasing air mass flow rate. Besides, the effect of chip heat flux on the thermal resistance of cold plate is insignificant; while the thermal resistance of cold plate decreases with increasing air mass flow rate. Three empirical correlations of thermal resistance in terms of air mass flow rate with a power of −0.228 are presented. As for average Nusselt number, the effect of chip heat flux on the average Nusselt number is insignificant; while the average Nusselt number of the cold plate increases with increasing Reynolds number. An empirical relationship between Nu¯cp and Re can be correlated. In the flow frictional aspect, the overall pressure drop of the cold plate increases with increasing air mass flow rate; while it is insignificantly affected by chip heat flux. An empirical correlation of the overall pressure drop in terms of air mass flow rate with a power of 1.265 is presented. Finally, both heat transfer performance factor “j” and pumping power factor “f” decrease with increasing Reynolds number in a power of 0.805; while they are independent of chip heat flux. The Colburn analogy can be adequately employed in the study.


In this investigation of multi heat pipe induced in heat exchanger shows the developments in heat transfer is to improve the efficiency of heat exchangers. Water is used as a heat transfer fluid and acetone is used as a working fluid. Rotameter is set to measure the flow rate of cold water and hot water. To maintain the parameter as experimental setup. Then set the mass flow rate of hot water as 40 LPH, 60LPH, 80 LPH, 100LPH, 120 LPH and mass flow rate of cold water as 20 LPH, 30 LPH, 40 LPH, 50 LPH, and 60 LPH. Then 40 C, 45 ºC, 50 ºC, 55 C, 60 ºC are the temperatures of hot water at inlet are maintained. To find some various physical parameters of Qc , hc , Re ,, Pr , Rth. The maximum effectiveness of the investigation obtained from condition of Thi 60 C, Tci 32 C and 100 LPH mhi, 60 LPH mci the maximum effectiveness attained as 57.25. Then the mhi as 100 LPH, mci as 60 LPH and Thi at 40 C as 37.6%. It shows the effectiveness get increased about 34.3 to the maximum conditions.


2020 ◽  
Vol 82 (3) ◽  
Author(s):  
Muji Setiyo ◽  
Budi Waluyo ◽  
Nurkholis Hamidi

The ½ cycle refrigeration system on LPG fueled vehicles has a significant cooling effect. However, the cooling is very dependent on the heat exchange process in the evaporator. Therefore, this paper analyses the deviation of the actual cooling curve from the ideal scenario carried out on a laboratory scale. The analytical method used is the calculation of the effectiveness of the evaporator, which compares the actual to the potential heat transfer capacity. The LPG flow rate was varied from 1-6 g/s, while the evaporation pressure ranged between 0.05, 0.10, and 0.15 MPa, which applied to compact type evaporators with dimensions of 262 ´ 200 mm, with a thickness of 65 mm. The research results confirm that the higher the LPG mass flow rate, the lower the heat transfer effectiveness. At the higher LPG mass flow rate, heat transfer occurs less optimally,  due to incomplete evaporation of LPG in the evaporator.


Author(s):  
Xingyun Jia ◽  
Liguo Wang ◽  
Qun Zheng ◽  
Hai Zhang ◽  
Yuting Jiang

Performance of generic rim seal configurations, axial-clearance rim seal (ACS), radial-clearance rim seal (RCS), radial-axial clearance rim seal (RACS) are compared under realistic working conditions. Conjugate heat transfer analysis on rim seal is performed in this paper to understand the impact of ingestion on disc temperature. Results show that seal effectiveness and cooling effectiveness of RACS are the best when compared with ACS and RCS, the minimum mass flow rate for seal of RACS is 75% of that of RCS, and 34.6% of ACS. Authors compare the disc temperature distribution between different generic rim seal configurations where the RACS seems to be favorable in terms of low disc temperature. In addition, RACS has higher air-cooled aerodynamic efficiency, minimizing the mainstream performance penalty when compared with ACS and RCS. Corresponding to the respective minimum mass flow rate for seal, the air-cooled aerodynamic efficiency of RACS is 23.71% higher than that of ACS, and 12.79% higher than the RCS.


Sign in / Sign up

Export Citation Format

Share Document