An Infrared Communication Module for the Enhancement of Hearing Aids

2018 ◽  
Vol 7 (3) ◽  
pp. 29-34
Author(s):  
Seong Mo Park
2014 ◽  
Vol 685 ◽  
pp. 302-305
Author(s):  
Hao Wang ◽  
Ze Yu Han

Infrared communication technology is a short-range wireless communications technology widely adopted in the world today range .This paper detailedly introduces the basic principles of infrared protocol. Infrared communications applications of this paper is to achieve system applications of infrared communication between two development boxes with an infrared transceiver modules.The program consists of PC program and lower computer program two parts,also are called infrared communication basic procedures and infrared communication console program.Running PC program on a PC,running lower computer program on the development box.Based on Borch-company's S3C2410-S ARM9, experimental development box implements a infrared communications infrastructure lower computer program based on serial meeting SIR standards.By calling the Qt graphics library,using the programming language C++,it achieves a visual infrared communication console PC program under linux system.


2014 ◽  
Vol 1030-1032 ◽  
pp. 1919-1924
Author(s):  
Bao Feng Li ◽  
Feng Zhai ◽  
Bao Ling He ◽  
Wen Jing Xu ◽  
Yong Feng Cao

In order to ensure the success rate for communication between the power field on-site service terminals and the smart meters, guarantee the on-site service terminals' infrared divergence Angle is controlled in a certain range, we designed a performance testing system. Through this system, we can understand the scattering intensity of the communication infrared light macroscopicly, the infrared light scattering areas also can be calculated. Moreover, we can detect whether the communication data are according with the requirement of communication protocols and determine whether the infrared communication module is qualified accurately.


1981 ◽  
Vol 12 (3) ◽  
pp. 139-144 ◽  
Author(s):  
Cletus G. Fisher ◽  
Kenneth Brooks

Classroom teachers were asked to list the traits they felt were characteristic of the elementary school child who wears a hearing aid. These listings were evaluated according to the desirability of the traits and were studied regarding frequency of occurrence, desirability, and educational, emotional, and social implications. The results of the groupings are discussed in terms of pre-service and in-service training.


1999 ◽  
Vol 30 (2) ◽  
pp. 165-172 ◽  
Author(s):  
Mary Davis ◽  
Rhonda Jackson ◽  
Tina Smith ◽  
William Cooper

Prior studies have proven the existence of the "hearing aid effect" when photographs of Caucasian males and females wearing a body aid, a post-auricular aid (behind-the-ear), or no hearing aid were judged by lay persons and professionals. This study was performed to determine if African American and Caucasian males, judged by female members of their own race, were likely to be judged in a similar manner on the basis of appearance, personality, assertiveness, and achievement. Sixty female undergraduate education majors (30 African American; 30 Caucasian) used a semantic differential scale to rate slides of preteen African American and Caucasian males, with and without hearing aids. The results of this study showed that female African American and Caucasian judges rated males of their respective races differently. The hearing aid effect was predominant among the Caucasian judges across the dimensions of appearance, personality, assertiveness, and achievement. In contrast, the African American judges only exhibited a hearing aid effect on the appearance dimension.


1994 ◽  
Vol 25 (2) ◽  
pp. 112-114 ◽  
Author(s):  
Henna Grunblatt ◽  
Lisa Daar

A program for providing information to children who are deaf about their deafness and addressing common concerns about deafness is detailed. Developed by a school audiologist and the school counselor, this two-part program is geared for children from 3 years to 15 years of age. The first part is an educational audiology program consisting of varied informational classes conducted by the audiologist. Five topics are addressed in this part of the program, including basic audiology, hearing aids, FM systems, audiograms, and student concerns. The second part of the program consists of individualized counseling. This involves both one-to-one counseling sessions between a student and the school counselor, as well as conjoint sessions conducted—with the student’s permission—by both the audiologist and the school counselor.


1990 ◽  
Vol 21 (3) ◽  
pp. 147-150
Author(s):  
Ronald A. Wilde

A commercial noise dose meter was used to estimate the equivalent noise dose received through high-gain hearing aids worn in a school for deaf children. There were no significant differences among nominal SSPL settings and all SSPL settings produced very high equivalent noise doses, although these are within the parameters of previous projections.


1992 ◽  
Vol 23 (3) ◽  
pp. 208-213 ◽  
Author(s):  
Marsha Lipscomb ◽  
Peggy Von Almen ◽  
James C. Blair

Twenty students between the ages of 6 and 19 years who were receiving services for students with hearing impairments in a metropolitan, inner-city school system were trained to monitor their own hearing aids. This study investigated the effect of this training on the percentage of students who wore functional hearing aids. Ten of the students received fewer than 3 hours of instruction per day in the regular education setting and generally had hearing losses in the severe to profound range. The remaining 10 students received greater than 3 hours of instruction per day in the regular education setting and had hearing losses in the moderate to severe range. The findings indicated improved hearing aid function when students were actively involved in hearing aid maintenance programs. Recommendations are made concerning hearing aid maintenance in the schools.


1996 ◽  
Vol 5 (1) ◽  
pp. 23-32 ◽  
Author(s):  
Chris Halpin ◽  
Barbara Herrmann ◽  
Margaret Whearty

The family described in this article provides an unusual opportunity to relate findings from genetic, histological, electrophysiological, psychophysical, and rehabilitative investigation. Although the total number evaluated is large (49), the known, living affected population is smaller (14), and these are spread from age 20 to age 59. As a result, the findings described above are those of a large-scale case study. Clearly, more data will be available through longitudinal study of the individuals documented in the course of this investigation but, given the slow nature of the progression in this disease, such studies will be undertaken after an interval of several years. The general picture presented to the audiologist who must rehabilitate these cases is that of a progressive cochlear degeneration that affects only thresholds at first, and then rapidly diminishes speech intelligibility. The expected result is that, after normal language development, the patient may accept hearing aids well, encouraged by the support of the family. Performance and satisfaction with the hearing aids is good, until the onset of the speech intelligibility loss, at which time the patient will encounter serious difficulties and may reject hearing aids as unhelpful. As the histological and electrophysiological results indicate, however, the eighth nerve remains viable, especially in the younger affected members, and success with cochlear implantation may be expected. Audiologic counseling efforts are aided by the presence of role models and support from the other affected members of the family. Speech-language pathology services were not considered important by the members of this family since their speech production developed normally and has remained very good. Self-correction of speech was supported by hearing aids and cochlear implants (Case 5’s speech production was documented in Perkell, Lane, Svirsky, & Webster, 1992). These patients received genetic counseling and, due to the high penetrance of the disease, exhibited serious concerns regarding future generations and the hope of a cure.


2019 ◽  
Vol 28 (2) ◽  
pp. 274-284 ◽  
Author(s):  
Elizabeth Convery ◽  
Gitte Keidser ◽  
Louise Hickson ◽  
Carly Meyer

Purpose Hearing loss self-management refers to the knowledge and skills people use to manage the effects of hearing loss on all aspects of their daily lives. The purpose of this study was to investigate the relationship between self-reported hearing loss self-management and hearing aid benefit and satisfaction. Method Thirty-seven adults with hearing loss, all of whom were current users of bilateral hearing aids, participated in this observational study. The participants completed self-report inventories probing their hearing loss self-management and hearing aid benefit and satisfaction. Correlation analysis was used to investigate the relationship between individual domains of hearing loss self-management and hearing aid benefit and satisfaction. Results Participants who reported better self-management of the effects of their hearing loss on their emotional well-being and social participation were more likely to report less aided listening difficulty in noisy and reverberant environments and greater satisfaction with the effect of their hearing aids on their self-image. Participants who reported better self-management in the areas of adhering to treatment, participating in shared decision making, accessing services and resources, attending appointments, and monitoring for changes in their hearing and functional status were more likely to report greater satisfaction with the sound quality and performance of their hearing aids. Conclusion Study findings highlight the potential for using information about a patient's hearing loss self-management in different domains as part of clinical decision making and management planning.


2019 ◽  
Vol 62 (5) ◽  
pp. 1486-1505
Author(s):  
Joshua M. Alexander

PurposeFrequency lowering in hearing aids can cause listeners to perceive [s] as [ʃ]. The S-SH Confusion Test, which consists of 66 minimal word pairs spoken by 6 female talkers, was designed to help clinicians and researchers document these negative side effects. This study's purpose was to use this new test to evaluate the hypothesis that these confusions will increase to the extent that low frequencies are altered.MethodTwenty-one listeners with normal hearing were each tested on 7 conditions. Three were control conditions that were low-pass filtered at 3.3, 5.0, and 9.1 kHz. Four conditions were processed with nonlinear frequency compression (NFC): 2 had a 3.3-kHz maximum audible output frequency (MAOF), with a start frequency (SF) of 1.6 or 2.2 kHz; 2 had a 5.0-kHz MAOF, with an SF of 1.6 or 4.0 kHz. Listeners' responses were analyzed using concepts from signal detection theory. Response times were also collected as a measure of cognitive processing.ResultsOverall, [s] for [ʃ] confusions were minimal. As predicted, [ʃ] for [s] confusions increased for NFC conditions with a lower versus higher MAOF and with a lower versus higher SF. Response times for trials with correct [s] responses were shortest for the 9.1-kHz control and increased for the 5.0- and 3.3-kHz controls. NFC response times were also significantly longer as MAOF and SF decreased. The NFC condition with the highest MAOF and SF had statistically shorter response times than its control condition, indicating that, under some circumstances, NFC may ease cognitive processing.ConclusionsLarge differences in the S-SH Confusion Test across frequency-lowering conditions show that it can be used to document a major negative side effect associated with frequency lowering. Smaller but significant differences in response times for correct [s] trials indicate that NFC can help or hinder cognitive processing, depending on its settings.


Sign in / Sign up

Export Citation Format

Share Document