scholarly journals Research on torque ripple under healthy and open-circuit fault-tolerant conditions in a PM multiphase machine

Author(s):  
Ali Akay ◽  
Paul Lefley
2020 ◽  
Vol 56 (5) ◽  
pp. 4955-4965 ◽  
Author(s):  
Yuliang Guo ◽  
Lijian Wu ◽  
Xiaoyan Huang ◽  
Youtong Fang ◽  
Jiaming Liu

2012 ◽  
Vol 433-440 ◽  
pp. 6776-6782
Author(s):  
Yi Feng Wu ◽  
Zhi Quan Deng ◽  
Yu Wang

In order to realize high power and reliability of speed control system, fault-tolerant induction motor control system based on three-level inverter is studied in this paper. Based on three-level inverter, a fault-tolerant inverter topology with an extra leg providing the current path during the post-fault operation is proposed. A corresponding control strategy is investigated to avoid voltage drift of the dc link midpoint. In this paper, an induction motor direct slip linear control (DSLC) is employed and investigated to reduce torque ripple and flux magnitude deviation in three-level system. Both simulation and experimental system have been set up to verify the effectiveness of the proposed control strategy.


Energies ◽  
2019 ◽  
Vol 12 (18) ◽  
pp. 3462 ◽  
Author(s):  
Hanying Gao ◽  
Wen Zhang ◽  
Yu Wang ◽  
Zhuo Chen

Multi-phase motors have attracted increasing attention in fields seeking high reliability, such as electric vehicles, ships, and rail transit, as they exhibit advantages, such as high reliability and fault tolerance. In this study, we consider a 12-phase permanent magnet synchronous motor (PMSM). First, a mathematical model of the 12-phase PMSM in the static coordinate system is established and the model is simplified according to the constraint condition of neutral point isolation. Second, according to the principle of invariant magnetomotive force under normal and fault conditions, two optimal control strategies of winding current, i.e. maximum torque output (MTO) and minimum copper consumption (MCC), are proposed. For a single-phase open-circuit fault, two optimization methods are used to reconstruct the residual phase current, such that the motor can maintain normal torque output and exhibit lower torque ripple under the fault state. Finally, system simulation and experimental research are conducted; the results verify the accuracy and feasibility of the fault-tolerant control strategy of the 12-phase PMSM proposed in this paper.


Energies ◽  
2021 ◽  
Vol 14 (11) ◽  
pp. 3163
Author(s):  
Chen Huang ◽  
Lidan Zhou ◽  
Zujia Cao ◽  
Gang Yao

Multi-phase motors and generators are regarded with great fault tolerance capability, especially on open-circuit faults. Various mathematics analytical methods are applied for their fault control. In this paper, a fault-tolerant control strategy with asymmetric phase current for the open-circuit faults with arbitrary phases in the six-phase PMSM (six-phase permanent magnetic synchronous motor, 6P-PMSM) system, is proposed for better electrical and dynamical performance of the machine. An innovative mathematical model for PMSM under one to four-phase-open circuit faults are established considering the asymmetry of the machine. Combining with time-varying relations in machines’ working conditions, targeted decoupling transformation matrixes of every kind of open-circuit faults are settled by voltage equations under different faults. Modified control strategy with a connection between the neutral point and the inverter’s DC side is presented, which aims at increasing the system redundancy and reducing the amplitude of phase currents. Besides, improved control loops with two layers are put forward as well, with which the PMSM system acquires fewer harmonics in phase current and smoother electromagnetic torque. Simulation and experimental results of open-circuit faults are provided for verification of the theoretical analysis.


Author(s):  
Meiling Zhao ◽  
Guohai Liu ◽  
Qian Chen ◽  
Wenxiang Zhao ◽  
Christopher H. T. Lee

Author(s):  
Umakanta Mahanta ◽  
Bhabesh Chandra Mohanta ◽  
Anup Kumar Panda ◽  
Bibhu Prasad Panigrahi

Torque ripple reduction is one of the major challenges in switching table-based direct torque control (DTC) while operating for open phase faults of an induction motor, as the switching vectors are unevenly distributed. This can be minimized by increasing the level of the inverter and with the use of multi-phase motors. Fuzzy logic-based DTC is another solution to the above problem. In this paper, a comparative analysis is done between switching table-based DTC (ST-DTC) and fuzzy logic-based DTC for increasing the performance during open phase faults of a five-phase induction motor. The result shows that in fuzzy logic-based DTC with a two-level inverter, the torque ripple is reduced by 5.164% as compared with ST-DTC with a three-level inverter. The fuzzy logic-based DTC with the three-level inverter also gives better performance as compared with fuzzy logic-based DTC with the two-level inverter. The current ripple also reduced by 9.605% with respect to ST-DTC. Thus, fuzzy logic-based DTC is more suitable and cost effective for open phase fault-tolerant drives.


Sign in / Sign up

Export Citation Format

Share Document