scholarly journals Application Notes - APD LAMP Diagnostic App: Automated Colorimetric Analysis and Documentation

Author(s):  
Zhen-Yi Chew ◽  
◽  
Wei-Ling Wu ◽  
Samuel Ken-En Gan ◽  
◽  
...  

Amidst rapid diagnostic kits, reverse transcription loop-mediated isothermal amplification (RT-LAMP) has emerged as a rapid point-of-care testing (POCT) method during the COVID-19 pandemic. While many POCT kits rely on plate readers or visual classifications, these processes require experienced staff, and with the use of plate readers, the need for peripheral equipment and infrastructure as well. To address the gap and ensure objectivity in colorimetric POCT kits, the Automated Product Determination (APD) LAMP Diagnostic App was developed for automatic colorimetric analysis of single to multiple LAMP samples. Leveraging on the smartphone camera, barcode-based documentation feature, and a colour distance formula, the app algorithm calculates RGB values, labelling samples as “positive” when yellow, “negative” when pink, and “unknown” when orange. The APD Lamp diagnostic app for Android hereby demonstrates the integration of smartphone apps in POCT kits and ways the smartphone revolution changes laboratory processes to be timely and on-the-go.

2021 ◽  
Vol 27 (1) ◽  
Author(s):  
Bruna de Oliveira Coelho ◽  
Heloisa Bruna Soligo Sanchuki ◽  
Dalila Luciola Zanette ◽  
Jeanine Marie Nardin ◽  
Hugo Manuel Paz Morales ◽  
...  

Abstract Background SARS-CoV-2 Reverse Transcription Loop-mediated Isothermal Amplification (RT-LAMP) colorimetric detection is a sensitive and specific point-of-care molecular biology technique used to detect the virus in only 30 min. In this manuscript we have described a few nuances of the technique still not properly described in the literature: the presence of three colors clusters; the correlation of the viral load with the color change; and the importance of using an internal control to avoid false-negative results. Methods To achieve these findings, we performed colorimetric RT-LAMP assays of 466 SARS-CoV-2 RT-qPCR validated clinical samples, with color quantification measured at 434 nm and 560 nm. Results First we determinate a sensitivity of 93.8% and specificity of 90.4%. In addition to the pink (negative) and yellow (positive) produced colors, we report for the first time the presence of an orange color cluster that may lead to wrong diagnosis. We also demonstrated using RT-qPCR and RT-LAMP that low viral loads are related to Ct values > 30, resulting in orange colors. We also demonstrated that the diagnosis of COVID-19 by colorimetric RT-LAMP is efficient until the fifth symptoms day when the viral load is still relatively high. Conclusion This study reports properties and indications for colorimetric RT-LAMP as point-of-care for SARS-CoV-2 diagnostic, reducing false results, interpretations and optimizing molecular diagnostics tests application.


Lab on a Chip ◽  
2018 ◽  
Vol 18 (18) ◽  
pp. 2854-2864 ◽  
Author(s):  
Junhou Hui ◽  
Yin Gu ◽  
Yuanshou Zhu ◽  
Yanjing Chen ◽  
Shu-juan Guo ◽  
...  

A pipette-actuated capillary array comb system controlled and detected on a smartphone-based hand-held device was developed for point-of-care testing.


2017 ◽  
Vol 89 (12) ◽  
pp. 6631-6636 ◽  
Author(s):  
Chang Feng ◽  
Xiaoxia Mao ◽  
Hai Shi ◽  
Bing Bo ◽  
Xiaoxia Chen ◽  
...  

2019 ◽  
Author(s):  
Aleksandra Anna Zasada ◽  
Aldona Wiatrzyk ◽  
Urszula Czajka ◽  
Klaudia Brodzik ◽  
Kamila Formińska ◽  
...  

Abstract Background Diphtheria outbreaks occurred in endemic areas and imported and indigenous cases are reported in UE/EEA. Because of the high infectiveness and severity of the disease, early and accurate diagnosis of each suspected case is essential for the treatment and management of the case and close contacts. The aim of the study was to establish simple and rapid testing methods based on Loop-Mediated Isothermal Amplification (LAMP) assay for the detection of Corynebacterium diphtheriae and differentiation between toxigenic and non-toxigenic strains.Methods Corynebacterium diphtheriae and Corynebacterium ulcerans isolates from the National Institute of Public Health-National Institute of Hygiene collection were used for the development of LAMP assay for the diagnosis of diphtheria and nontoxigenic C. diphtheriae infections. Various colorimetric methods for visualization of results were investigated. Sensitivity and specificity of the assay were examined using a collection of DNA samples from various gram-positive and gram-negative bacteria.Results The LAMP assay for tox and dtxR genes was developed. The sensitivity and specificity of the assay were calculated as 100%. The detection limit was estimated as 1.42 pg/µl concentration of DNA template when the reaction was conducted for 60 min. However, the detection limit was lowered 10 times for every 10 minutes of reduction in the time of incubation during the reaction. Positive results were successfully detected colorimetrically using hydroxynaphthol blue, calcein, QuantiFluor, and lateral flow Milenia HybriDetect dipsticks.Conclusion The assay developed in the study might be applied for point-of-care testing of diphtheria and other C. diphtheriae infections. It is highly sensitive, specific, inexpensive, easy to use, and suitable for low-resource settings.


2020 ◽  
Vol 20 (1) ◽  
Author(s):  
Marc F. Österdahl ◽  
Karla A. Lee ◽  
Mary Ni Lochlainn ◽  
Stuart Wilson ◽  
Sam Douthwaite ◽  
...  

Abstract Background A cost effective and efficient diagnostic tool for COVID-19 as near to the point of care (PoC) as possible would be a game changer in the current pandemic. We tested reverse transcription loop mediated isothermal amplification (RT-LAMP), a method which can produce results in under 30 min, alongside standard methods in a real-life clinical setting. Methods This prospective service improvement project piloted an RT-LAMP method on nasal and pharyngeal swabs on 21 residents of a high dependency care home, with two index COVID-19 cases, and compared it to multiplex tandem reverse transcription polymerase chain reaction (RT-PCR). We recorded vital signs of patients to correlate clinical and laboratory information and calculated the sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of a single swab using RT-LAMP compared with the current standard, RT-PCR, as per Standards for Reporting Diagnostic Accuracy Studies (STARD) guidelines. Results The novel method accurately detected 8/10 RT-PCR positive cases and identified a further 3 positive cases. Eight further cases were negative using both methods. Using repeated RT-PCR as a “gold standard”, the sensitivity and specificity of a single novel test were 80 and 73% respectively. PPV was 73% and NPV was 83%. Incorporating retesting of low signal RT-LAMP positives improved the specificity to 100%. We also speculate that hypothermia may be a significant early clinical sign of COVID-19. Conclusions RT-LAMP testing for SARS-CoV-2 was found to be promising, fast and to work equivalently to RT-PCR methods. RT-LAMP has the potential to transform COVID-19 detection, bringing rapid and accurate testing to the PoC. RT-LAMP could be deployed in mobile community testing units, care homes and hospitals to detect disease early and prevent spread.


Pathogens ◽  
2021 ◽  
Vol 10 (12) ◽  
pp. 1629
Author(s):  
Alexander Domnich ◽  
Andrea Orsi ◽  
Donatella Panatto ◽  
Vanessa De Pace ◽  
Valentina Ricucci ◽  
...  

Although the reverse transcription-polymerase chain reaction (RT-PCR) is considered a standard-of-care assay for the laboratory diagnosis of SARS-CoV-2, several limitations of this method have been described. Reverse transcription loop-mediated isothermal amplification (RT-LAMP) is an alternative molecular assay and is potentially able to overcome some intrinsic shortcomings of RT-PCR. In this study, we evaluated the diagnostic performance of the novel HG COVID-19 RT-LAMP assay. In this retrospective analysis, a total of 400 routinely collected leftover nasopharyngeal samples with a known RT-PCR result were tested by means of the HG COVID-19 RT-LAMP assay. The overall sensitivity and specificity values of HG COVID-19 RT-LAMP versus RT-PCR were 97.0% (95% CI: 93.6–98.9%) and 98.5% (95% CI: 95.7–99.7%), respectively. Inter-assay agreement was almost perfect (κ = 0.96). Concordance was perfect in samples with high viral loads (cycle threshold < 30). The average time to a positive result on RT-LAMP was 17 min. HG COVID-19 RT-LAMP is a reliable molecular diagnostic kit for detecting SARS-CoV-2, and its performance is comparable to that of RT-PCR. Shorter turnaround times and the possibility of performing molecular diagnostics in the point-of-care setting make it a valuable option for facilities without sophisticated laboratory equipment.


Sign in / Sign up

Export Citation Format

Share Document