Analysis of the Features of the Behavior of Track Membrane Filters during their Use

2020 ◽  
Vol 75 (3) ◽  
pp. 277-285
Author(s):  
E. A. Ivleva ◽  
Yu. V. Alekhin ◽  
M. A. Makarova
Author(s):  
Lawrence W. Ortiz ◽  
Bonnie L. Isom

A procedure is described for the quantitative transfer of fibers and particulates collected on membrane filters to electron microscope (EM) grids. Various Millipore MF filters (Millipore AA, HA, GS, and VM; 0.8, 0.45, 0.22 and 0.05 μm mean pore size) have been used with success. Observed particle losses have not been size dependent and have not exceeded 10%. With fibers (glass or asbestos) as the collected media this observed loss is approximately 3%.


2009 ◽  
Vol 129 (11) ◽  
pp. 380-386 ◽  
Author(s):  
Taizo Kobayashi ◽  
Daiki Kato ◽  
Hiroyuki Koga ◽  
Kenichi Morimoto ◽  
Makoto Fukuda ◽  
...  

1993 ◽  
Vol 27 (3-4) ◽  
pp. 1-13 ◽  
Author(s):  
Arie H. Havelaar ◽  
Siem H. Heisterkamp ◽  
Janneke A. Hoekstra ◽  
Kirsten A. Mooijman

The general concept of measurement errors is applied to quantitative bacteriological counts on membrane filters or agar plates. The systematic errors of these methods are related to the growth characteristics of the medium (recovery of target organisms and inhibition of non-target organisms) and to its differential characteristics (sensitivity and specificity). Factors that influence the precision of microbiological counts are the variation between replicates, within samples, between operators and between laboratories. It is also affected by the linearity of the method, the verification rate and, where applicable, the number of colonies subcultured for verification. Repeatability (r) and reproducibility (R) values can be calculated on the logarithmic scale.


1997 ◽  
Vol 35 (11-12) ◽  
pp. 77-80 ◽  
Author(s):  
A. Wiedenmann ◽  
M. Braun ◽  
K. Botzenhart

A simple continuous flow device in which bacteria were immobilised on membrane filters and flushed with tap water with free chlorine residuals of 0.05, 0.1, 0.2 and 0.4mg/L at pH 7.7 and 10°C, has been used for disinfection experiments with faecal streptococci. A 99.99% reduction of Enterococcus faecium was observed between 3.4–5.2min (0.05mg/L), between 2.8–4.1min (0.1mg/L), between 1.7–3.1min (0.2mg/L) and between 0.8–2.1min (0.4mg/L). CT-products covered a range of 0.17 (0.05mg/L, lower limit) up to 0.85mg/L/min (0.4mg/L, upper limit). The test system is suggested as a more reliable alternative to batch experiments when the disinfection potential of low chlorine concentrations acting for several minutes has to be evaluated. The system cannot be used to demonstrate exact reduction kinetics but it allows the calculation of CT values and the evaluation of the disinfection potential of chlorinated water at any point of a distribution system where initial chlorine concentrations may have already remarkably declined.


2021 ◽  
Vol 127 (1) ◽  
Author(s):  
D. Fong ◽  
L. J. Cummings ◽  
S. J. Chapman ◽  
P. Sanaei
Keyword(s):  

Minerals ◽  
2021 ◽  
Vol 11 (4) ◽  
pp. 426
Author(s):  
Behrooz Abbasi ◽  
Xiaoliang Wang ◽  
Judith C. Chow ◽  
John G. Watson ◽  
Bijan Peik ◽  
...  

Respirable coal mine dust (RCMD) exposure is associated with black lung and silicosis diseases in underground miners. Although only RCMD mass and silica concentrations are regulated, it is possible that particle size, surface area, and other chemical constituents also contribute to its adverse health effects. This review summarizes measurement technologies for RCMD mass concentrations, morphology, size distributions, and chemical compositions, with examples from published efforts where these methods have been applied. Some state-of-the-art technologies presented in this paper have not been certified as intrinsically safe, and caution should be exerted for their use in explosive environments. RCMD mass concentrations are most often obtained by filter sampling followed by gravimetric analysis, but recent requirements for real-time monitoring by continuous personal dust monitors (CPDM) enable quicker exposure risk assessments. Emerging low-cost photometers provide an opportunity for a wider deployment of real-time exposure assessment. Particle size distributions can be determined by microscopy, cascade impactors, aerodynamic spectrometers, optical particle counters, and electrical mobility analyzers, each with unique advantages and limitations. Different filter media are required to collect integrated samples over working shifts for comprehensive chemical analysis. Teflon membrane filters are used for mass by gravimetry, elements by energy dispersive X-ray fluorescence, rare-earth elements by inductively coupled plasma-mass spectrometry and mineralogy by X-ray diffraction. Quartz fiber filters are analyzed for organic, elemental, and brown carbon by thermal/optical methods and non-polar organics by thermal desorption-gas chromatography-mass spectrometry. Polycarbonate-membrane filters are analyzed for morphology and elements by scanning electron microscopy (SEM) with energy dispersive X-ray, and quartz content by Fourier-transform infrared spectroscopy and Raman spectroscopy.


2004 ◽  
Vol 35 (6) ◽  
pp. 731-741 ◽  
Author(s):  
Naomichi Yamamoto ◽  
Minoru Fujii ◽  
Kazukiyo Kumagai ◽  
Yukio Yanagisawa

Sign in / Sign up

Export Citation Format

Share Document