Experimental Investigation of Vapor Compression Refrigeration System Performance Using Nano-Refrigerant

2014 ◽  
Vol 2 (2) ◽  
pp. 12-27
Author(s):  
Ahmed J. Hamad

     Experimental investigation of vapor compression refrigeration system performance using Nano-refrigerant is presented in this work. Nano-refrigerant was prepared in current work by mixing 50 nanometers diameter of copper oxide CuO nanoparticles with Polyolester lubrication oil and added to the compressor of the refrigeration system to be mixed with pure refrigerant R-134a during its circulation through refrigeration system. Three concentrations (0.1%, 0.25%, and 0.4%) of CuO-R134 a Nano-refrigerant are used to study the performance of the refrigeration system test rig and to investigate the effect of using Nano-refrigerant as a working fluid compared with pure refrigerant R-134a. The results showed that, the increasing in concentration of CuO nanoparticles in the Nano-refrigerant will significantly enhance the performance of the refrigeration system, as adding nanoparticles will increase the thermal conductivity, heat transfer and improve the thermo-physical properties of Nano-refrigerant. Investigation of performance parameters for refrigeration system using Nano-refrigerant with 0.4% concentration compared with that for pure refrigerant R-134a shows that, Nano-refrigerant has reflect higher performance in range of 10% and 1.5% increase in COP and refrigeration effect respectively and 7% reduction in power consumption for refrigeration system. It can be concluded that, Nano-refrigerants can be efficiently and economically feasible to be used in the vapor compression refrigeration systems.

Author(s):  
Ms. K. P. Bhangle

Abstract: The capillary tube is commonly employed in refrigerant flow control systems. As a result, the capillary tube's performance is optimal for good refrigerant flow. Many scholars concluded performance utilising experimental, theoretical, and analysis-based methods. This paper examines the flow analysis of a refrigerant within a capillary tube under adiabatic flow circumstances. For a given mass flow rate, the suggested model can predict flow characteristics in adiabatic capillary tubes. In the current work, R-134a refrigerant has been replaced by R600a refrigerant as a working fluid inside the capillary tube, and the capillary tube design has been modified by altering length and diameter, which were obtained from reputable literature. The analysis is carried out using the ANSYS CFX 16.2 software. The results show thatutilising a small diameter and a long length (R600a refrigerant flow) is superior to the present helical capillary tube. The most appropriate helical coiled design with a diameter of 0.8 mm and a length of 3 m is proposed. Keywords: Capillary Tube, Condenser, Refrigeration effect, CFD.


Author(s):  
Vikas Kumar ◽  
Gulshan Sachdeva ◽  
Sandeep Tiwari ◽  
Parinam Anuradha ◽  
Vaibhav Jain

A conventional vapor compression refrigeration system (VCRS) cascaded with a heat-assisted ejector refrigeration system (ERS) has been experimentally analyzed. Cascading allows the VCRS to operate at lower condenser temperatures and thus achieve a higher coefficient of performance. In this cascaded system, the condenser of the vapor compression system does not dissipate its heat directly to the evaporator of the ERS; instead, water circulates between the condenser of VCRS and the evaporator of ERS to exchange the heat. Seven ejectors of different geometries have been used in the ERS; however, all the ejectors could not maintain thermal equilibrium at the desired operating conditions. The compressor of the cascaded VCRS consumed 1.3 times less power than the noncascaded VCRS. Furthermore, the cascaded system provided a maximum 87.74% improvement in COP over the noncascaded system for the same operating conditions. The performance of the system remained constant until the critical condenser pressure of the ERS.


2013 ◽  
Vol 14 (1) ◽  
Author(s):  
A. B. Kasaeian ◽  
S. Daviran

In this study, a new model of a solar combined ejector-vapor compression refrigeration system has been considered. The system is equipped with an internal heat exchanger to enhance the performance of the cycle. The effects of working fluid and operating conditions on the system performance including COP, entrainment ratio (ω), compression ratio (rp) and exergy efficiency were investigated. Some working fluids suggested are: R114, R141b, R123, R245fa, R600a, R365mfc, R1234ze(e) and R1234ze(z). The results show that R114 and R1234ze(e) yield the highest COP and exergy efficiency followed by R123, R245fa, R365mfc, R141b, R152a and R600a. It is noticed that the COP value of the new solar ejector-vapor compression refrigeration cycle is higher than that of the conventional ejector cycle with R1234ze(e) for all operating conditions. This paper also demonstrates that R1234ze(e) will be a suitable refrigerant in the solar combined ejector-vapor compression refrigeration system, due to its environmental friendly properties and better performance. ABSTRAK: Kajian ini menganalisa model baru sistem penyejukan mampatan gabungan ejektor-wap solar.Sistem ini dilengkapi dengan penukar haba dalaman untuk meningkatkan prestasi kitaran.Kesan bendalir bekerja dan keadaan operasi pada prestasi sistem termasuk COP, nisbah pemerangkapan (ω), nisbah mampatan (rp) dan kecekapan eksergi telah disiasat.Beberapa bendalir bekerja yang dicadangkan adalah: R114, R141b, R123, R245fa, R600a, R365mfc, R1234ze(e) dan R1234ze(z).Hasil kajian menunjukkan R114 dan R1234ze(e) menghasilkan COP dan kecekapan eksergi tertinggi diikuti oleh R123, R245fa, R365mfc, R141b, R152a dan R600a.Didapati nilai COP kitaran penyejukan mampatan bagi ejektor-wap solar baru adalah lebih tinggi daripada kitaran ejektor konvensional dengan R1234ze(e) bagi semua keadaan operasi.Kertas kerja ini juga menunjukkan bahawa R1234ze(e) boleh menjadi penyejuk yang sesuai dalam sistem penyejukan mampatan gabungan ejektor -wap solar, kerana ianya mempunyai prestasi yang lebih baik serta sifatnya yang lebih mesra alam sekitar. KEYWORDS: environmental friendly refrigerants; solar combined ejector-vapor compression cycle; R1234ze(e)


Author(s):  
V. Zhelezny ◽  
S. Korniievych ◽  
O. Khliyeva ◽  
D. Ivchenko

An investigation of the saturated vapor pressure for the solutions of propane in the two type of industrial compressor oils ProEco®RF22S and RENISO SP46, also as in oil ProEco®RF22S containing fullerene C60 6.837·10-4kg·kg-1is presented in this paper. The measurement of the saturated vapor pressure was conducted using a static method in a temperature range (273…333) K and thepropanemass fraction (0.11…0.595) kg·kg-1. An analysis revealed that the expanded uncertainties of the measured saturated vapor pressure do not exceed 0.0419·105Pafor solutionpropane/ProEco®RF22S,0.0716·105Pa for solution propane /RENISO SP46, and 0.0095·105Pa for solution propane/ProEco®RF22 Scontaining C60.The temperature and concentration dependences of the saturated vapor pressure for the object of study have been discussed. The excess of saturated vapor pressure for the solution of propane in oil ProEco®RF22S over the pressure of the solution of propane in oil RENISO SP46 reaches 1.5 105 Pa at a temperature of 330 K and propane fractionof 0.1 kg·kg-1. This effect decreases with temperature decreasing and propane fraction increasing.It was proven that the additive of the fullerene C60 increase the saturated vapor pressure of the solution propane/ProEco® RF22S up to 0.4·105Pa at low temperature and low propane mass fraction insolution. The results obtained proved the expediency of the introduction in the industry the solution of propane/compressor oil ProEco® RF22Scontaining the fullerene C60 as working fluid of vapor compression refrigeration system. The ability of C60additive in oil to increase the saturated vapor pressure of considered working fluid will contribute to increasing the energy efficiency of refrigeration systems.


This paper gives preliminary aftereffects of VCR (Vapor Compression Refrigeration) go through setting twisted strip inside the condenser tube, using liquid suction warmth exchanger (lshe), and R134a as refrigerant in this cycle. examination executed on basic condenser tube with 3 different bended point strips verified in condenser tubes on the element of liquid suction heat exchanger for subcooling to remove suitable COP from cutting edge VCR machine. inside the proposed, lshe are taken through using each the procedures, strip focuses, α=a hundred,one hundred forty &one hundred eighty by methods for undeniable chamber and with subcooling. The proposed check has additionally made a through and through appraisal of COP, refrigeration influence, charge of impact and capability. in the communicated test; it's miles put that the drop in weight is 16% for the twisted strip tube condenser while in evaluation to customary condenser tube. other than it's in like manner seen that condenser with bowed strip implanted increments quick rot inside the temperature of evaporator than basic chamber. The effect and viability of misshaped strip verified cylinder condenser is unnecessary as strain drop falls in the condenser and decline of evaporator temperature


Author(s):  
Lucas Silva ◽  
JOÃO PEDRO ◽  
Ewerton Augusto Sousa Nogueira ◽  
José Felipe Dias ◽  
Sabrina Nogueira Rabelo