Numerical investigation of Heat Transfer Enhancement in Circular Tube using Twisted Tape Inserts and Nanotechnology

2017 ◽  
Vol 5 (2) ◽  
pp. 42-54
Author(s):  
Najim Abid Jassim ◽  
Kamel Abdul Hussin ◽  
Noor Yahya Abdul Abbass

In the present work the analysis of three different width ratio of twisted tape in a shell and tube heat exchanger done by ANSYS FLUINT14.0. Heat exchanger type shell and tube have been widely used in industrial application such as refrigeration and environment protection, electrical power generation and chemical engineering. This work deals with the theoretical investigation, which was to evaluate the benefit of changing the width of twisted tape in the heat exchanger and the improving the heat transfer by using water as the working fluid in the first case, then using Nano fluids as a heat transfer working fluid. From the use of the condition in table (1) the simulation shows results of enhancement in heat transfer rate ranging from (53.24% to 55.55%) at width ratio 0.71, (53.62% to 56.09%) at width ratio 0.854 and (52.44% to 57.17%) at width ratio 1, for plain tube with twisted tape with respect to plain tube without twisted tape by using water as cooling fluid. By using Nano- fluid (AL2O3) the enhancement in heat transfer is (69.14% to 60.44%) at width ratio 0.71, (58.36% to 61.51%) at width ratio 0.854 and (56.76% to 63.35%) at width ratio1, for plain tube with twisted tape with respect to plain tube without twisted tape.

Fluids ◽  
2021 ◽  
Vol 6 (7) ◽  
pp. 247
Author(s):  
Lokesh Pandey ◽  
Satyendra Singh

The present investigation constitutes CFD analysis of the heat transmission phenomenon in a tube heat exchanger with a Y-shaped insert with triangular perforation. The analysis is accomplished by considering air as a working fluid with a Reynolds number ranging from 3000 to 21,000. The segment considered for analysis consists of a circular tube of 68 mm diameter and 1.5 m length. The geometrical parameter considered is the perforation index (0%, 10%, 20%, and 30%). The constant heat flux is provided at the tube wall and a pressure-based solver is used for the solution. The studies are performed for analyzing the effects of inserts on the heat transfer and friction factor in the circular tube heat exchanger which results in augmented heat transfer at a higher perforation index (PI) and lower friction factor. The investigation results show that the highest heat transfer is 5.84 times over a simple plain tube and the maximum thermal performance factor (TPF) is 3.25 at PI = 30%, Re = 3000.


2020 ◽  
Author(s):  
sreejesh S R chandran ◽  
Debabrata Barik ◽  
ANSALAM RAJ T G ◽  
Reby ROY

Abstract Nanofluids are generally utilized in providing cooling, lubrication phenomenon, controlling the thermophysical properties of the working fluid. In this work, nanoparticles of Al2O3 are added to the base fluid which flows through the counter flow arrangement in a turbulent flow condition. The hot and cold fluids used are ethylbenzene and water respectively and have different velocities on both shell and tube side. This study emphasizes the analysis of flow properties, friction loss, and energy transfer in terms of heat using nanofluid in the heat exchanger. The heat transfer rate of present investigation with nanoparticle addition is 4.63% higher in comparision to Dittus Boelter correlation. Apart from this, the obtained friction factor is 0.0376 very much closer to Gnielinski and Blasius correlations. This investigation proved that appropriate nanoparticle additions and baffle inclinations have fabulous impact upon the performance of heat exchanger and its effectiveness.


2020 ◽  
Vol 9 (1) ◽  
pp. 1793-1798

A heat exchanger is a device intensively used for enhancing the transfer of heat energy between two or more working fluids at different temperature, which are in thermal contact. The optimal design and efficient operation of heat exchanger and heat transfer network are of a great significance in any of the process industry. The heat transfer efficiency depends on both design of heat exchanger and property of working fluid. From various types of heat exchanger, the double stacked shell and tube heat exchanger with straight tube and single pass is to be under study. Here the redesign of heat exchanger takes place with the key objectives of optimizing the pressure drop, optimizing the heat transfer rate and reducing the saddle support weight used for cooling purpose in brewery application. The design calculations are carried out using the Kerns and Bell Delwar method and other important parameters dealing with material selection and geometries are also taken into consideration. FEA analysis for optimizing the saddle support weight is carried out using Dassault systeme’s Solidworks while the CFD analysis for optimizing pressure drop and heat transfer rate is carried out using Dassault systeme’s Solidworks analysis software and the design and working of Shell and tube heat exchanger is determined in terms of variables such as pressure ,temperature ,mass flow rate ,flow rate ,energy input output that are of particular interest in Shell and tube heat exchanger analysis.


2021 ◽  
Author(s):  
I Made Arsana ◽  
Ruri Agung Wahyuono

As shell and tube heat exchanger is widely employed in various field of industries, heat exchanger design remains a constant optimization challenge to improve its performance. The heat exchanger design includes not only the architectural geometry of either the shell and tube configuration or the additional baffles but also the working fluid. The baffle design including the baffle angle and the baffle distance has been understood as key parameter controlling the overall heat exchanger effectiveness. In addition, a room of improvement is open by substituting the conventional working fluid with the nanomaterials-enriched nanofluid. The nanomaterials, e.g. Al2O3, SiO2, TiO2, increases the thermal conductivity of the working fluids, and hence, the more efficient heat transfer process can be achieved. This chapter provide an insight on the performance improvement of shell and tube heat exchanger by modifying the baffle design and utilizing nanofluids.


Author(s):  
S. Mohanty ◽  
R. Arora

In this investigation, a comprehensive approach is established in detail to analyse the effectiveness of the shell and tube heat exchanger (STE) with 50% baffle cuts (Bc) with varying number of baffles. CFD simulations were conducted on a single pass and single tube heat exchanger(HE) using water as working fluid. A counterflow technique is implemented for this simulation study. Based on different approaches made on design analysis for a heat exchanger, here, a mini shell and tube exchanger (STE) computational model is developed. Commercial CFD software package ANSYS-Fluent 14.0 was used for computational analysis and comparison with existing literature in the view of certain variables; in particular, baffle cut, baffle spacing, the outcome of shell and tube diameter on the pressure drop and heat transfer coefficient. However, the simulation results are more circumscribed with the applied turbulence models such as Spalart-Allmaras, k-ɛ standard and k-ɛ realizable. For determining the best among the turbulence models, the computational results are validated with the existing literature. The proposed study portrays an in-depth outlook and visualization of heat transfer coefficient and pressure drop along the length of the heat exchanger(HE). The modified design of the heat exchanger yields a maximum of 44% pressure drop reduction and an increment of 60.66% in heat transfer.


Symmetry ◽  
2020 ◽  
Vol 12 (10) ◽  
pp. 1652
Author(s):  
Mehdi Ghalambaz ◽  
Ramin Mashayekhi ◽  
Hossein Arasteh ◽  
Hafiz Muhammad Ali ◽  
Pouyan Talebizadehsardari ◽  
...  

This paper investigates the convective heat transfer in a heat exchanger equipped with twisted tape elements to examine effects of the twisted tape truncation percentage, pitch value, position and Reynolds number using 3D numerical simulation. A symmetric heat flux is applied around the tube as the studied heat exchanger. Based on the influences in both heat transfer enhancement and pressure drop, the performance evaluation criterion (PEC) is utilized. Inserting twisted tape elements and reducing the pitch value significantly augment the Nusselt number, friction coefficient and PEC number compared to the plain tube. For the best case with a Reynolds number of 1000, the average Nusselt number increases by almost 151%, which is the case of fully fitted twisted tape at a pitch value of L/4. Moreover, increasing the twisted tape truncation percentage reduces both heat transfer and pressure drop. Furthermore, the highest heat transfer rate is achieved when the truncated twisted tape is located at the entrance of the tube. Finally, it is concluded that for P = L, L/2, L/3 and L/4, the optimum cases from the viewpoint of energy conservation are twisted tapes with truncation percentages of 75, 50, 50 and 0%, in which the related PEC numbers at a Reynolds number of 1000 are almost equal to 1.08, 1.24, 1.4 and 1.76, respectively.


Author(s):  
Shamkuwar S.C ◽  
◽  
Nitin Chopra ◽  
Mihir Kulkarni ◽  
Nikhil Ahire ◽  
...  

The main objective of the paper is to compare the performance of Shell and tube heat exchanger (STHE) and Plate heat exchanger (PHE) used in chillers. The paper deals with experimental investigation and comparison, which is based on actual testing of STHE and PHE. Both heat exchangers were designed and tested for a heat load of 6000 kcal/hr. In both types of heat exchangers, the primary working fluid used is Refrigerant R22 and secondary working fluid used is water. Theoretical analysis shows that PHE has a 9.67 % less heat transfer area than STHE. Experimental results show that overall heat transfer coefficient (OHTC) for PHE is higher than STHE by 30.96%. The paper also includes a comparison of the heat transfer rate (Q) of the two heat exchangers experimentally.


Author(s):  
Moses Omolayo Petinrin ◽  
Ademola Adebukola Dare

In this study, comparative performance of single-segmental baffle and a newly developed baffle – convex-cut in shell-and-tube heat exchanger were both numerically and experimentally investigated. For the numerical analysis, three working fluids (engine oil, water and air) were successively utilised on the shell-side of heat exchangers with 30, 35, 40 and 45% convex-cut (CeC_STHE) and 25% segmental (SS_STHE) baffles, and the resulting models were solved in COMSOL Multiphysics. Experiments were carried out on 30% CeC_STHE and SS_STHE exclusively running on water. The data obtained were used to determine the weighted shell-side heat transfer coefficient and weighted performance factor of each heat exchanger. Hence, the results for all the ranges of Reynolds number indicate that the shell-side heat transfer coefficients of all the CeC_STHEs are lower than that of SS_STHE except for the 30% CeC_STHE. However, the SS_STHE showed greater pressure drop than the CeC_STHEs. The choice of working fluid had more influenced on the weighted shell-side heat transfer coefficient CeC_STHE. Moreover, the weighted performance factors of the CeC_STHEs indicated positive values. Thus, 30% CeC_STHE demonstrated a better performance while the 45% had the lowest performance.