scholarly journals Aplikasi Filter Pasif RC untuk Mereduksi Harmonik pada AC/DC/AC Konverter

2019 ◽  
Author(s):  
Asnil

This paper presents the design and analysis of a low pass passive filter to reduce harmonics component at the ac side (input) of three-phase ac/dc/ac converter. The filter configuration consists of resistor and capasitor, that cut off the frequency above 150 Hz

2018 ◽  
Author(s):  
Asnil

This paper presents the design and analysis of a low pass passive filter to reduce harmonics component at the ac side (input) of three-phase ac/dc/ac converter. The filter configuration consists of resistor and capasitor, that cut off the frequency above 150 Hz.


2017 ◽  
Vol 12 (1) ◽  
pp. 207-216 ◽  
Author(s):  
O. Fatih Kececioglu ◽  
Hakan Acikgoz ◽  
Ceyhun Yildiz ◽  
Ahmet Gani ◽  
Mustafa Sekkeli

2018 ◽  
Vol 18 (1) ◽  
pp. 35 ◽  
Author(s):  
Rofiatul Izah ◽  
Subiyanto Subiyanto ◽  
Dhidik Prastiyanto

Synchronous Reference Frame Phase Locked Loop (SRF PLL) has been widely used for synchronization three-phase grid-connected photovoltaic (PV) system. On the grid fault, SRF PLL distorted by negative sequence component and grid harmonic that caused an error in estimating parameter because of ripple and oscillation. This work combined SRF PLL with Dual Second Order Generalized Integrator (DSOGI) and filter to minimize ripple and minimize oscillation in the phase estimation and frequency estimation. DSOGI was used for filtering and obtaining the 90o shifted versions from the vαβ signals. These signals (vαβ) were generated from three phase grid voltage signal using Clarke transform. The vαβ signal was the inputs to the positive-sequence calculator (PSC). The positive-sequence vαβ was transformed to the dq synchronous reference frame and became an input to SRF-PLL to create the estimation frequency. This estimation frequency from SRF PLL was filtered by the low-pass filter to decrease grid harmonic. Moreover, the output of low-pass filter was a frequency adaptive. The performance of DSOGI PLL with filter is compared with DSOGI PLL, SRF PLL, and IEEE standard 1547(TM)-2003. The improvement of DSOGI PLL with filter gave better performances than DSOGI PLL and SRF PLLbecause it minimized ripples and oscillations in the phase and frequency estimations.


2018 ◽  
Vol 65 (11) ◽  
pp. 9025-9029 ◽  
Author(s):  
Parag Kanjiya ◽  
Vinod Khadkikar ◽  
Mohamed Shawky El Moursi

Energies ◽  
2020 ◽  
Vol 13 (11) ◽  
pp. 2923
Author(s):  
Matias Berg ◽  
Tomi Roinila

Grid-connected and grid-forming inverters play essential roles in the utilization of renewable energy. One problem of such a converter system is the voltage deviations in the DC-link between the source and the inverter that can disrupt the inverter output voltage. A common method to prevent these voltage deviations is to apply an input-voltage feedforward control. However, the feedforward control has detrimental effects on the inverter dynamics. It is shown that the effect of the feedforward in the input-to-output dynamics is not ideal due to the delay in the digital control system. The delay affects the input-to-output dynamics at high frequencies, and only a minor improvement can be achieved by low-pass filtering the feedforward control signal. Furthermore, the feedforward control can remarkably affect the inverter input admittance, and therefore, impedance-based stability problems may arise at the DC interface. This paper proposes a method based on linearization and extra element theorem to model the effect of the feedforward control in the inverter dynamics. Experimental measurements are shown to demonstrate the effectiveness of the proposed model.


2020 ◽  
Vol 15 (1) ◽  
pp. 181-186
Author(s):  
Tilak Giri ◽  
Ram Prasad Pandey ◽  
Sabin Bhandari ◽  
Sujan Moktan ◽  
Lagat Karki

Due to intensive use of power converters and other non-linear loads, power quality is degrading. The presence of harmonics in the power lines result in greater power losses in distribution, interference problems in communication systems. Non linearity reduces the efficiency and power factor of the system. As the power factor reduces, the reactive power demanded from the supply increases which have no any contribution in energy transfer, so compensation is required. For this, shunt passive filter has been developed but it is bulky and frequency dependent and has many drawbacks. In contrast to passive filter, shunt active filter (SAF) has been developed which is smaller and has wide range of applications. In this paper, shunt active filter based on p-q theory is demonstrated for compensating reactive power and current harmonics. Simulation has been done with and without SAF and results are presented and ended with recommendation and conclusion. An effort is made to reduce the THD of the source current below 5% (specified by IEEE).


2013 ◽  
Vol 575-576 ◽  
pp. 293-296
Author(s):  
Qun Min Yan

in order to solve the problem of three-phase static inverter output waveform distortion, detailed analyzed of the voltage distortion caused by the deadband effect and the resulting harmonic components. The control method is proposed to set the deadband time combining with the voltage compensation, while in order to improve the inverter output, the converter output to design a trap filter and a low pass filter cascaded filtering circuit. Simulated analysis the entire system though Saber, using the digital chip TMS320F2812 to achieve appropriate compensation strategies, simulation results and experimental results have all proved the effectiveness of the design method.


Sign in / Sign up

Export Citation Format

Share Document