Factors Associated With PSA False Negative and False Positive Results and the Impact on Patient's Health: A Cohort Study

Author(s):  
Medicine ◽  
2019 ◽  
Vol 98 (40) ◽  
pp. e17451 ◽  
Author(s):  
Mari Carmen Bernal-Soriano ◽  
Lucy A. Parker ◽  
Maite López-Garrigos ◽  
Ildefonso Hernández-Aguado ◽  
Juan P. Caballero-Romeu ◽  
...  

2005 ◽  
Vol 71 (11) ◽  
pp. 955-962 ◽  
Author(s):  
Rachel C. Forbes ◽  
Clovis Pitchford ◽  
Jean F. Simpson ◽  
Glen C. Balch ◽  
Mark C. Kelley

Imprint cytology (touch prep) is often used for intraoperative examination of sentinel nodes in breast cancer. This allows axillary lymph node dissection (ALND) to be performed immediately for tumor-positive nodes. We evaluated the accuracy of touch prep examination of sentinel nodes and its role in the surgical treatment of breast cancer. We analyzed 169 breast cancer patients who underwent 170 lymphatic mapping procedures with intraoperative touch prep examination. Results from the touch prep were correlated with histopathology and clinical variables. There were 115 true-negative, 35 true-positive, 15 false-negative, and 5 false-positive results. Touch prep had a sensitivity of 70 per cent and specificity of 96 per cent. Positive predictive value, negative predictive value, and diagnostic accuracy were all 88 per cent. The false-negative rate was 30 per cent and correlated with the size of the nodal metastasis and number of involved nodes, but not other patient factors. Touch prep is useful for the evaluation of sentinel nodes in breast cancer, but it has a lower sensitivity than initially reported, particularly in patients with micrometastases. False positive results occur, although they may be reduced after experience with the technique. We recommend that suspicious findings on touch prep should be confirmed by frozen section and that ALND only be performed for histologically documented metastases. We currently perform touch prep only in patients who are at high risk of nodal metastasis or will undergo mastectomy. This improves operative efficiency and limits the impact of false positive and negative results without dramatically increasing the number of patients who require a second surgical procedure.


1974 ◽  
Vol 31 (02) ◽  
pp. 273-278
Author(s):  
Kenneth K Wu ◽  
John C Hoak ◽  
Robert W Barnes ◽  
Stuart L Frankel

SummaryIn order to evaluate its daily variability and reliability, impedance phlebography was performed daily or on alternate days on 61 patients with deep vein thrombosis, of whom 47 also had 125I-fibrinogen uptake tests and 22 had radiographic venography. The results showed that impedance phlebography was highly variable and poorly reliable. False positive results were noted in 8 limbs (18%) and false negative results in 3 limbs (7%). Despite its being simple, rapid and noninvasive, its clinical usefulness is doubtful when performed according to the original method.


PEDIATRICS ◽  
1987 ◽  
Vol 79 (2) ◽  
pp. 203-205
Author(s):  
Mendel Tuchman ◽  
Margaret L. R. Ramnaraine ◽  
William G. Woods ◽  
William Krivit

During the last 3 years, random urine samples from 408 patients were tested for elevated homovanillic acid (HVA) and vanillylmandelic acid (VMA) levels to rule out the diagnosis of neuroblastoma. Thirty-seven of these patients had elevated HVA and/or VMA levels, and neuroblastoma was subsequently diagnosed. In three additional patients with negative test results (normal HVA and VMA levels), tumors were subsequently diagnosed (false-negative rate of 7.5%). Ten percent of the patients with neuroblastoma had normal HVA and 27.5% had normal VMA levels at the time of diagnosis. Only one patient (2.5%) with neuroblastoma had elevated VMA levels in the presence of normal HVA levels. More than 60% of the patients with neuroblastoma had urinary HVA and/or VMA levels higher than twice the upper limit of normal. No false-positive results were encountered. Age and stage distributions of the patients are shown, and the significance of the results is discussed.


The Lancet ◽  
1972 ◽  
Vol 299 (7764) ◽  
pp. 1341-1342 ◽  
Author(s):  
RonaldP. Ng ◽  
T.K. Chan ◽  
D. Todd

PEDIATRICS ◽  
1996 ◽  
Vol 98 (1) ◽  
pp. 41-44
Author(s):  
Judy G. Saslow ◽  
Ernest M. Post ◽  
Carol A. Southard

Objective. As neonatal discharge before 24 hours of life becomes commonplace, the rejection of congenital hypothyroidism (CH) screening specimens obtained too early has created the need for numerous additional tests. We sought to determine whether the specimens obtained before 24 hours could be used safely. Methods. During a 31-day period we measured thyrotropin in all thyroid-screening specimens that had been obtained before 24 hours. We also examined the early specimens from every infant diagnosed in New Jersey with CH during 1993 or 1994. Results. Among the 663 specimens, those obtained at or before 12 hours and those from infants with birth weights less than 2500 g had too many low thyroxine results to be useful. Among the 515 specimens obtained at more than 12 to 24 hours from newborns weighing 2500 g or more, 37 (7%) had low thyroxine levels and 12 (2.3%) had thyrotropin levels of 20 µIU/mL (mU/L) or higher. Four hundred seventy-one of the 515 infants had subsequent specimens obtained at more than 24 hours, and none of the results were abnormal. There was no child weighing more than or equal to 2500 g who was diagnosed with CH in 1993 and 1994 whose specimen obtained at 24 hours or less was normal. Conclusions. Accepting specimens obtained at more than 12 to 24 hours from infants weighing 2500 g or more would have resulted in more than the usual number of false-positive results but no false-negative results. This would have decreased the requests for additional specimens by more than 90%.


Sign in / Sign up

Export Citation Format

Share Document