scholarly journals QR VERIFICATION OF LABORATORY STUDIES RESULTS

Author(s):  
K. Kadirkulov ◽  
А. Ismailova ◽  
A. Beissegul ◽  
A. Satybaldiyeva

This article describes the practical using of QR codes [1] verification of laboratory studies results. QR codes have become widely used in all industries as quick identification of information and the implementation of transactional actions, where encrypted URL allows to quickly scanning by using a smartphone camera. Digitalization contributes to the transition to the online environment of healthcare, office workers, education and to receive more data on the spread of diseases, exchange information and quickly receive laboratory results without distortion. The presented solution is a component of the LIS SmartLAB platform [2], which performs complex automation of laboratories of the different profiles, observing all work processes to obtain reliable results by direct interaction with laboratory equipment according to international standards HL7 (Health Level 7 - "Seventh level"), ASTM (American Society for Testing and Materials - "American Society for Testing Materials") and automatic detection of deviations from standard values [3]. In 2019, there was a pilot implementation of QR verification of results based on the laboratory of the Skin and venereal dispensary of the Almaty, the results of which made it possible to introduce QR codes into other profiles of laboratory diagnostics, such as PCR (polymerase chain reaction), genetics, microbiology and clinical diagnostics. Now, due to the pandemic, all laboratory results for the detection of RNA of the COVID-19 virus must contain a QR code to avoid falsification of the results.

TAPPI Journal ◽  
2010 ◽  
Vol 9 (4) ◽  
pp. 31-36 ◽  
Author(s):  
YULIN DENG ◽  
PHIL JONES ◽  
LESLIE MCLAIN ◽  
ART J. RAGAUSKAS

High-filler-content paper is a growing research and development opportunity in papermaking. These new products must address traditional paper product properties while providing papermakers with distinct product platform benefits. Over the past decade, a research team involving researchers from the Institute of Paper Science and Technology at Georgia Institute of Technology and from Imerys have significantly advanced the application of starch-encapsulated papermaking fillers. This review summarizes these accomplishments from initial laboratory studies to mill trials. Laboratory results have illustrated that starch-encapsulated fillers can facilitate a near-doubling of filler content over conventional levels at equal tensile and z-direction tensile (ZDT) values. Equally important is that the use of starch-encapsulated kaolin (SEK) filler has been shown to facilitate a doubling of filler addition rate without any detrimental impact on ring crush compared with control studies with filler. Pilot-plant and mill trials have shown that SEK can function as a fiber extender, reduce steam demand for drying by 10%, and increase papermaking speeds and production rates.


2021 ◽  
Author(s):  
Baobin Han ◽  
Peng Cheng ◽  
Yihang Yu ◽  
Wenda Yang ◽  
Zhilin Tian ◽  
...  

<p>Laboratory studies indicated that soil could produce considerable nitrous acid (HONO) emissions, which is the main primary source of hydroxyl radical (OH) in the troposphere. However, very few field observations of HONO emission from soil were reported. In order to relate laboratory results and field measurements, we measured HONO emissions from 7 representative agricultural soils (rice, vegetables, orchards, peanuts, potatoes, sugarcane and maize) in Guangdong under controlled laboratory conditions, and took flux measurements on 2 of them (rice and vegetables) by dynamic chambers in the field. Generally, release rates of HONO from the seven soils increased with temperature and varied with soil moisture, and the optimum release rates can be reached under specific values of water-filled pore space (WFPS), which is considered to be beneficial to nitrification. The seven soils' optimum release rates ranged from 1.24 to 43.19 ng kg<sup>-1</sup> s<sup>-1</sup>, and the Q<sub>10</sub> (It is defined as the multiple of the increase of soil gas emission rate when the temperature increases by 10℃) ranged from 1.03 to 2.25. Formulas were deduced from the lab results to express HONO emissions for every soil. Flux measurements on two soils varied around -1 to 4 ng N m<sup>-2</sup> s<sup>-1</sup>, and both showed similar diurnal variations with peaks around noontime and very low even negative values during nighttime. There were good correlations between HONO fluxes and soil temperature (R<sup>2</sup>=0.5). Furthermore, irrigation enhanced the HONO emission substantially. However, a large discrepancy existed between soil HONO emissions measured in lab and low HONO fluxes in field. More investigations are needed to explain the paradox.</p>


Author(s):  
Charles R. Brinkman

An update is presented of the activities of the American Society for Testing and Materials (ASTM) Committee C-28 on Advanced Ceramics. Since its inception in 1986, this committee, which has five standard producing subcommittees, has written and published over 32 consensus standards. These standards are concerned with mechanical testing of monolithic and composite ceramics, nondestructive examination, statistical analysis and design, powder characterization, quantitative microscopy, fractography, and terminology. These standards ensure optimum material behavior with physical and mechanical property reproducibility, component reliability, and well-defined methods of data treatment and material analysis for both monolithic and composite materials. Committee C-28 continues to sponsor technical symposia and to cooperate in the development of international standards. An update of recent and current activities as well as possible new areas of standardization work will be presented.


Solar Energy ◽  
2002 ◽  
Author(s):  
Daryl R. Myers ◽  
Keith Emery ◽  
C. Gueymard

In 1982, the American Society for Testing and Materials (ASTM) adopted consensus standard direct-normal and global-tilted solar terrestrial spectra (ASTM E891/E892). These standard spectra were intended to evaluate photovoltaic (PV) device performance and other solar-related applications. The International Standards Organization (ISO) and International Electrotechnical Commission (IEC) adopted these spectra as spectral standards ISO 9845-1 and IEC 60904-3. Additional information and more accurately representative spectra are needed by today’s PV community. Modern terrestrial spectral radiation models, knowledge of atmospheric physics, and measured radiometric quantities are applied to develop new reference spectra for consideration by ASTM.


2018 ◽  
Vol 879 ◽  
pp. 248-253
Author(s):  
Papatsorn Singhatham ◽  
Chokchai Singhatham ◽  
Niphaporn Panya ◽  
Salakchit Pukjaroon

The research purposes to design, analyze and build a report (MDR) integrity. To use as the MDR prototype in accordance with international standards for industrial factories. The MDR is important to the operator of equipment, the factories, and petrochemical industry because of it is an index for the quality assurance, quality control of fabrication and planning of maintenance management (material upgrade/ equipment change) for safety during equipment operation. When the equipment has a problem we can check for cause from the fabrication history data on MDR. A survey was developed for people concerned with the MDR, totaling 141 people from 58 factories in Thailand industrial sector for find out the demands and problems on using the MDR. The result shows that preparation of the MDR can cost more than a week of time, with no clear pattern of standard format and require manpower more than 3 peoples. In summary, the development of the MDR prototype by comparative data between, the manufacturer, the Ministry of Industry of Thailand and the American Society of Mechanical Engineers (ASME). The specialists who have the experience in the MDR to determine the completeness and validate all content in the MDR 15 chapters.


2021 ◽  
Vol 9 (12) ◽  
pp. 148
Author(s):  
Mauro Pascolutti ◽  
Dileusa de Oliveira

Background: Traditional bleaching agents based on hydrogen peroxide (HP) or carbamide peroxide (CP) have adverse soft and hard tissue effects. Objectives: This study tested a novel formulation of phthalimidoperoxycaproic acid (PAP) with additives to optimise its safety and effectiveness. Methods: A novel gel (PAP+) was formulated. Laboratory studies assessed effects of six 10-minute exposures to PAP+ vs. commercial CP and HP gels, using surface profilometry and microhardness. The effectiveness of PAP+ in vitro against complex polyphenol stains on enamel was compared to 6% HP. Results: Unlike HP gels, PAP+ gel did not erode enamel. Unlike both CP and HP gels, PAP+ gel did not reduce the surface microhardness of enamel. PAP+ gel on used on polyphenol stains was superior to 6% HP. In this model, six repeated 10-minute treatments with PAP+ gel could improve the shade by approximately eight VITA® Bleachedguide shades. Conclusions: These laboratory results support the safety and effectiveness of this new PAP formula and its use as an alternative to CP and HP with superior safety and effectiveness.


2016 ◽  
Vol 65 (4) ◽  
pp. 76-82
Author(s):  
Elena V. Shipitsina ◽  
Tatyana A. Khusnutdinova ◽  
Olga S. Ryzhkova ◽  
Anna A. Krysanova ◽  
Olga V. Budilovskaya ◽  
...  

Introduction. Bacterial vaginosis (BV) is associated with a number of reproductive health disorders, therefore timely and accurate diagnosis of this condition is exceedingly important. Objective.Comparison of effectiveness of clinical and laboratory diagnostics of BV in women with vaginal discharge. Material and methods. In total, 318 patients addressing gynecological clinics with complaints about vaginal discharge participated in the study. Clinical diagnostics of BV was performed in the clinics participating in patient enrollment in accordance with their clinical practice. For laboratory diagnostics, microscopy of Gram stained smears according to the Nugent method and quantitative real-time PCR were used. Sensitivity and specificity of clinical diagnostics of BV and the molecular method were evaluated using the Nugent method as reference standard. Results. With the Nugent method, BV was diagnosed in 27% of women, with real-time PCR — in 37% of women. Using clinical signs of BV, the condition was diagnosed in 91% women. Sensitivity and specificity of the real-time PCR were 97% and 87%, respectively. Sensitivity of clinical diagnostics was 100%, but specificity was only 17%. Conclusions. Diagnostics of BV based only on the presence of vaginal discharge leads to false positive results and requires laboratory confirmation. The molecular method has a high sensitivity and satisfactory specificity for BV diagnosis and can be used as an alternative to the Nugent method.


PLoS ONE ◽  
2021 ◽  
Vol 16 (9) ◽  
pp. e0256045
Author(s):  
René Staritzbichler ◽  
Pascal Hunold ◽  
Irina Estrela-Lopis ◽  
Peter Werner Hildebrand ◽  
Berend Isermann ◽  
...  

Raman spectroscopy has shown to be a promising method for the examination of biomedical samples. However, until now, its efficacy has not been established in clinical diagnostics. In this study, Raman spectroscopy’s potential application in medical laboratories is evaluated for a large variety (38) of biomarkers. Given 234 serum samples from a cohort of patients with different stages of liver disease, we performed Raman spectroscopy at 780nm excitation wavelength. The Raman spectra were analyzed in combination with the results of routine diagnostics using specifically developed complex mathematical algorithms, including fluorescence filtering, frequency subset selection and several overfitting circumventing strategies, such as independent validation. With the results of this cohort, which were validated in 328 independent samples, a significant proof-of-concept study was completed. This study highlights the need to prevent overfitting and to use independent data for validation. The results reveal that Raman spectroscopy has high potential for use in medical laboratory diagnostics to simultaneously quantify multiple biomarkers.


Sign in / Sign up

Export Citation Format

Share Document