Forth International Topical Meeting on Neutron Radiography (ITMNR 5) Electronic Neutron Imaging Systems and Their Application

Author(s):  
Hisao KOBAYASHI
Author(s):  
Andrew T. Boothroyd

The description of neutron optical phenomena within the framework of dynamical diffraction theory is described. The coherent wave and optical potential are introduced, and an expression for the complex neutron refractive index in terms of the scattering length density and attenuation coefficient is obtained. The extension to magnetic media and polarized neutrons is covered. Neutron reflectivity is defined, and the wavevector dependence of the reflectivity profile is derived by a transfer matrix method and an optical method. Exact results are compared with the Born approximation. The technique of neutron imaging is described, including neutron radiography and computed tomography. Several optical phenomena that occur in Bragg diffraction from near-perfect crystals, including Pendellösung oscillations, and primary and secondary extinction.


Instruments ◽  
2019 ◽  
Vol 3 (2) ◽  
pp. 32 ◽  
Author(s):  
Federica Mingrone ◽  
Marco Calviani ◽  
Claudio Torregrosa Martin ◽  
Oliver Aberle ◽  
Michael Bacak ◽  
...  

A neutron radiography testing station has been developed exploiting the neutron beam of CERN’s n_TOF Experimental Area 2, located at the shortest distance to the neutron producing-target. The characteristics of the n_TOF neutron beam for the imaging setup are presented in this paper, together with the obtained experimental results. The results focused on the testing of several particle producing targets, including a spent antiproton production targets as well as targets from two different HiRadMat’s experiments. The possible developments of neutron imaging capabilities of the n_TOF facility in terms of detection-systems and beam-line upgrades are as well outlined.


2013 ◽  
Vol 92 (2-3) ◽  
pp. 177-180 ◽  
Author(s):  
A.S. Schulp ◽  
R. Schouten ◽  
L. Metten ◽  
A. van de Sande ◽  
A. Bontenbal

AbstractIn the conservation of fragile fossil bone material, impregnation by solvent-borne consolidant is often required. Understanding the mode of penetration of consolidants into fossil bone is of crucial importance. It is governed by a variety of factors; neutron imaging is a powerful tool to monitor and visualise this penetration (non-destructively). The consolidation of a vertebrate fossil from the Maastrichtian of the southeast Netherlands was imaged at the High Flux Reactor facility at Petten, the Netherlands. The analysis shows current conservation practice to result in a sufficiently deep and isotropic penetration.


2019 ◽  
Vol 54 (9) ◽  
pp. 1217-1231 ◽  
Author(s):  
Ebrahim Oromiehie ◽  
Ulf Garbe ◽  
B Gangadhara Prusty

Automated fibre placement-based manufacturing technology is increasingly being used in several engineering applications. Manufacture of carbon fibre-reinforced plastic’s small/large structures have been made possible due to its remarkable capabilities like productivity and accuracy. Nevertheless, making high-quality composite laminate using automated fibre placement relies on the proper selection of critical processing variables to avoid internal flaws during the fibre placement process. Consequently, a reliable non-destructive inspection technique is required for quality assurance and structural integrity of fabricated laminates. Neutron radiography/tomography offers unique imaging capabilities over a wide range of applications including fibre-reinforced polymer composites. The application of this technique towards tomographic reconstruction of automated fibre placement-made thermoplastic composites is presented in this paper. It is shown that the porosity analysis using neutron imaging technique provides reliable information. Additionally, using such technique valuable data regarding the size and the location of the voids in the laminate can be acquired and informed. This will assist the composite structural analysts and designers to select the appropriate processing parameters towards a defect free automated fibre placement part manufacture.


2016 ◽  
Vol 56 (5) ◽  
pp. 388-394 ◽  
Author(s):  
Jan Šácha ◽  
Michal Sněhota ◽  
Jan Hovind

This paper presents an empirical method by Kang et al. recently proposed for correcting two-dimensional neutron radiography for water quantification in soil. The method was tested on data from neutron imaging of the water infiltration in a soil sample. The raw data were affected by neutron scattering and by beam hardening artefacts. Two strategies for identifying the correction parameters are proposed in this paper. The method has been further developed for the case of three-dimensional neutron tomography. In a related experiment, neutron imaging is used to record ponded-infiltration experiments in two artificial soil samples. Radiograms, i.e., two-dimensional projections of the sample, were acquired during infiltration. A calculation was made of the amount of water and its distribution within the radiograms, in the form of two-dimensional water thickness maps. Tomograms were reconstructed from the corrected and uncorrected water thickness maps to obtain the 3D spatial distribution of the water content within the sample. Without the correction, the beam hardening and the scattering effects overestimated the water content values close to the perimeter of the sample, and at the same time underestimated the values close to the centre of the sample. The total water content of the entire sample was the same in both cases. The empirical correction method presented in this study is a relatively accurate, rapid and simple way to obtain the quantitatively determined water content from two-dimensional and three-dimensional neutron images. However, an independent method for measuring the total water volume in the sample is needed in order to identify the correction parameters.


Holzforschung ◽  
2012 ◽  
Vol 66 (6) ◽  
pp. 751-756 ◽  
Author(s):  
Sabine Rosner ◽  
Martin Riegler ◽  
Peter Vontobel ◽  
David Mannes ◽  
Eberhard H. Lehmann ◽  
...  

Abstract This study is a first approach to visualize moisture distribution and movement between annual rings during sapwood drying by neutron imaging (NI). While Norway spruce [Picea abies (L.) Karst.] sapwood beams were allowed to dehydrate on a balance at ambient conditions, NI was performed in 1–10 min time steps. From NI raw files, radial dimensional changes were calculated during dehydration and transmission profiles were drawn for different relative moisture content (MC) steps from full saturation until equilibrium moisture content. The NI technique proved to be a useful tool to visualize the movement of free water within, and between, annual rings. Removal of free water in the middle part of the wood beam did not proceed continuously from the surface to the central part, but was strongly influenced by wood anatomy. Water is removed from earlywood during early stages of dehydration and later, at higher moisture loss (<50% MC), from the main latewood parts. It is therefore concluded that the radial dimensional changes measured at moderate moisture loss are not only caused by cell wall shrinkage of the outer wood parts located beneath the wood surface, but a result of elastic deformation of earlywood tracheids under the influence of negative hydrostatic pressures.


2021 ◽  
Vol 5 (1) ◽  
pp. 6-14
Author(s):  
K.M. Nazarov ◽  
B. Mukhametuly ◽  
S.E. Kichanov ◽  
T.K. Zholdybayev ◽  
A.A. Shaimerdenov ◽  
...  

Since 2019, the TITAN neutron radiography and tomography facility have been operating at the WWR-K research reactor. The experimental station is intended for a wide range of applications in various fields of science. Since the launch, several interesting works have been carried out to study the internal features of lithium-ion batteries and geophysical materials. The spatial resolution of the detector system was sufficient to visualize the internal elements of the lithium battery and to separate individual grains of the pyrite mineral in the rock sample. This paper presents the technical parameters of the experimental setup and the results of the recent applied research.


Sign in / Sign up

Export Citation Format

Share Document