scholarly journals Spatial-temporal variation and modeling of rainwater quality

2021 ◽  
Vol 10 (3) ◽  
pp. e45810313598
Author(s):  
Emmanuel Kennedy da Costa Teixeira ◽  
Letícia Gabriela Andrade Policarpo ◽  
Suely Riciati da Silva ◽  
Eliane Prado Cunha Costa dos Santos

Rainwater harvesting (RWH) is an alternative to the problem of water scarcity. However, its quality must be analyzed before its use, so that it does not represent any danger to the consumer. Thus, the objective of this paper was to analyze the spatial-temporal variation of water quality of rainwater in two cities and observe whether its parameters meet the norm related to the subject. In addition, the concentration of total suspended solids (TSS) that flow into the drainage system was also simulated. Rainwater samples were collected at several points in Congonhas and Ouro Branco - MG, over a period of two years. The results showed that there was spatial-temporal variation in water quality. There were points where the quality met the standard in some moments and did not meet in others, due to its temporal variation. It was also observed that the catchment surface influenced the quality of rainwater, so that the water that came into contact with the roof had its quality deteriorated, at first. However, throughout the rainy event, the quality improved, but at certain times, it was not enough to meet the standard. The rainwater quality simulation, carried out at SWMM, showed high concentrations of TSS, which were higher to that allowed for launching into receiving bodies.

2014 ◽  
Vol 70 (8) ◽  
pp. 1341-1347 ◽  
Author(s):  
V. C. Andrés-Valeri ◽  
D. Castro-Fresno ◽  
L. A. Sañudo-Fontaneda ◽  
J. Rodriguez-Hernandez

Three different drainage systems were built in a roadside car park located on the outskirts of Oviedo (Spain): two sustainable urban drainage systems (SUDS), a swale and a filter drain; and one conventional drainage system, a concrete ditch, which is representative of the most frequently used roadside drainage system in Spain. The concentrations of pollutants were analyzed in the outflow of all three systems in order to compare their capacity to improve water quality. Physicochemical water quality parameters such as dissolved oxygen, total suspended solids, pH, electrical conductivity, turbidity and total petroleum hydrocarbons were monitored and analyzed for 25 months. Results are presented in detail showing significantly smaller amounts of outflow pollutants in SUDS than in conventional drainage systems, especially in the filter drain which provided the best performance.


2010 ◽  
Vol 61 (7) ◽  
pp. 1707-1714 ◽  
Author(s):  
S. Ward ◽  
F. A. Memon ◽  
D. Butler

This paper summarises the physicochemical and microbiological quality of water from a rainwater harvesting (RWH) system in a UK-based office building. 7 microbiological and 34 physicochemical parameters were analysed during an 8 month period. Physicochemically, harvested rainwater quality posed little health risk; most parameters showed concentrations below widely used guideline levels for drinking water. However, RWH system components (e.g. fittings and down pipes) appear to be affected soft water corrosion, resulting in high concentrations of some metals (copper, zinc and aluminium). This suggests the material selection of such fittings should be considered keeping in view the hardness of rainwater of an area. Microbiologically, Cryptosporidium, Salmonella and Legionella were not present in the samples analysed. However, faecal coliform counts were high at the beginning of the study, but did decrease over time in weak correlation with increasing pH. Enterococcus faecalis displayed counts consistently above UK rainwater harvesting standards. Inappropriate roof and rainwater good design, as well as material selection appear to be responsible for the reduced microbial quality, as they promoted contributions from avian sources and inhibited cleaning activities. Building and RWH system designs require greater consideration of local factors, which are critical for optimising harvested rainwater quality, to prevent both the development of contaminated sediments and health impacts.


2016 ◽  
Vol 19 (4) ◽  
pp. 249-258
Author(s):  
Huong Thi Diem Bui ◽  
Tuan Ngoc Le

This study aims at assessing changes in the surface water quality in Dong Nai province (2010- 2014). In addtion, the pollutant loads of wastewater sources were calculated till 2020–2030 with 03 wastewater treatment scenarios serving for the local environmental management. The water quality index (WQI) showed the surface water quality of Dong Nai Province to be gradually improved during the dry season but significantly declined in the rainy season in the last 5 years due to high concentrations of suspended solids (SS), Fe and microorganism - especially in the 3rd segment of Dong Nai river through Bien Hoa City. This current status certainly relates to pollutant loads from waste water sources in the province. Pollutant loads of domestic and industrial wastewater in Bien Hoa city are the highest (40 % per source), livestock activities in Xuan Loc district account for 20 %; aquaculture activities in Nhon Trach district contribute more than 75 % of the corresponding total loads, etc. in which loads of BOD5, COD and SS are significant, about 581,570 tons, 1,035,403 tons and 639,153 tons per year, respectively, and tend to increase in the future, requiring appropriate solutions.


2021 ◽  
Vol 8 (9) ◽  
pp. 168-172
Author(s):  
Md. Sazzadul Haque ◽  
◽  
Fatema Naznin Rinkey ◽  

Since rainwater harvesting system was assessed to be potential in residential, industrial, educational and other institutions so the study was focused on the rainwater quality of samples collected from rooftop surface runoff of different locations of Dhaka city which is the 2nd most polluted city of the world. Locations were based upon residential, commercial, industrial zone within the area, motorized vehicles use, population, construction works etc. The rooftops were taken mainly of concrete made rooftops and within a single area 03 locations were chosen and a sample of rainwater was collected from a tin made rooftop within that area. The main purpose of this assessment was to compare the rainwater quality of different locations with the drinking water quality standards of Bangladesh and World Health Organization (WHO) in order to observe whether the water needs of further treatment or not for potable use. The samples were checked of physical (Turbidity) and chemical (pH, Electric Conductivity, Total Dissolved Solids, Nitrate, Nitrite, Sulfate, Chloride & Fluoride) characteristics of water quality. In terms of pH, Nitrate and Fluoride values, there were significant imbalance with the standards and thus required treatment for potable use. And other parameters were within the standards.


Author(s):  
Jose Simmonds ◽  
Juan A. Gómez ◽  
Agapito Ledezma

This article contains a multivariate analysis (MV), data mining (DM) techniques and water quality index (WQI) metrics which were applied to a water quality dataset from three water quality monitoring stations in the Petaquilla River Basin, Panama, to understand the environmental stress on the river and to assess the feasibility for drinking. Principal Components and Factor Analysis (PCA/FA), indicated that the factors which changed the quality of the water for the two seasons differed. During the low flow season, water quality showed to be influenced by turbidity (NTU) and total suspended solids (TSS). For the high flow season, main changes on water quality were characterized by an inverse relation of NTU and TSS with electrical conductivity (EC) and chlorides (Cl), followed by sources of agricultural pollution. To complement the MV analysis, DM techniques like cluster analysis (CA) and classification (CLA) was applied and to assess the quality of the water for drinking, a WQI.


2021 ◽  
Vol 50 (4) ◽  
pp. 23-53
Author(s):  
Ranya M. Salah Eldin ◽  
Noha S. Donia ◽  
Ashraf E. Ismail

2017 ◽  
Vol 5 (4RASM) ◽  
pp. 71-77
Author(s):  
Babitha Rani ◽  
Dimple Bahri ◽  
Prabin Neupane ◽  
Kunal Kothari ◽  
Vishal Gadgihalli ◽  
...  

A study was carried out to find out the water quality ofByramangala lake of Ramanagara district. The water quality of Byramangala lake water and ground water from bore wells situated in the area within 600 meters surrounding the lake was analyzed. The quality analysis of various parameters such as BODs, COD, DO, E-Coli, and pH, Total Dissolved Solids, Total Suspended Solids and Total Hardness were tested. In addition, the presence of metals such as Cadmium (Cd), Chromium (Cr), Lead (Pb), and Iron (Fe) in the lake water and ground water samples were tested. Results for the various tests conducted showed similar trends for both lake water and ground water. It was observed that certain parameters such as BOD5, and COD were beyond permissible limits as per the BIS standards for drinking water. A few remedial measures have been proposed that may help in mitigating the pollution in the selected project area Byramangala Lake.


2002 ◽  
Vol 45 (1) ◽  
pp. 103-110 ◽  
Author(s):  
E. Giraldo ◽  
A. Garzón

The potential application of Water Hyacinth (Eichhornia crassipes) in organic matter degradation, sedimentation, nutrient and heavy metal absorption and sulfur reduction in the Muña Reservoir has been tested in experimental lagoons. The lagoons were operated at hydraulic retention times (HRT) of 6, 9 and 15 days. One lagoon was covered with Water Hyacinth, which is naturally growing in the Muña Reservoir, while another lagoon was operated as a conventional oxidation pond. The Water Hyacinth lagoon had better removal efficiencies for almost all parameters measured: BOD5, total suspended solids, COD, nitrogen, phosphorus and heavy metals. The oxidation lagoon was facultative for HRT of 9 and 15 days, and anoxic when operated at 6 days HRT. At HRT of 15 days the water quality in the effluent of the covered lagoon corresponded to 12 mg/l of BOD, 6 mg/l of suspended solids and 0.8 mg/l of hydrogen sulfide. Hydrogen sulfide levels in the Muña reservoir can be substantially reduced at HRT higher than 15 days in both lagoons. The uncovered lagoon had better hydrogen sulfide removal during the day but presents high levels at night. If the hydraulic retention time in the Muña reservoir is increased, the water quality of the Bogota river can be substantially improved for all the HRTs tested in the pilot units. HRT seems to give a better prediction of overall effluent water quality than surface loading. More research is needed in order to define the optimum water hyacinth density in the Muña reservoir to determine its influence on the water quality of the effluent. The influence is expected to be negative due to an internal increase of BOD, solids, nutrients and metals loads due to plant decay.


Sign in / Sign up

Export Citation Format

Share Document