scholarly journals Effect of fluoride on the thickness, surface roughness and corrosion resistance of titanium anodic oxide films formed in a phosphate buffer solution at different applied potentials

2020 ◽  
Vol 9 (11) ◽  
pp. e95791110689
Author(s):  
Gláucia Domingues ◽  
Michele de Almeida Oliveira ◽  
Nayne Barros Gonzaga Ferreira ◽  
Bhetina Cunha Gomes ◽  
Elivelton Alves Ferreira ◽  
...  

The anodizing process and anions type present in the electrolyte during anodic oxidation are important parameters to improve oxide biocompatibility. From these parameters, it is possible to control the thickness and surface roughness of the oxide film. This control is of major importance, once blood clots can be avoided when the oxide film on the metal substrate has a small surface roughness (Ra ≤ 50 nm). In this paper, the thickness, surface roughness, and corrosion resistance of the anodized titanium film were studied in a phosphate buffer solution containing fluoride anions (0.6 w.t % NaF), at 20 V, 40 V, 60 V, and 80 V, using atomic force microscopy (AFM), spectroscopic ellipsometry (SE), and electrochemical impedance spectroscopy (EIS) techniques. It was observed that thickness and roughness tend to increase as the applied potential rises. For oxides grown in the solution without NaF, the growth rate is roughly 1.3 ± 0.2 nm/V. Surface roughness generally presents the same behaviour. Moreover, EIS and SE thickness measurements agree at 20 V and 60 V but disagree at 80 V. This may be associated with a possible dielectric breakdown at 80 V. The oxide film formed at 60 V showed the best corrosion resistance in relation to the other studied potentials. Globular structures were also observed using AFM on surfaces at 40 V, 60 V, and 80 V, which suggests oxide film nucleation. Oxide films formed in solution with NaF presented lower thickness, excellent corrosion resistance, and low surface roughness (Ra ≤ 50 nm).

1998 ◽  
Vol 441 (1-2) ◽  
pp. 5-12 ◽  
Author(s):  
T.M. Silva ◽  
A.M.P. Simões ◽  
M.G.S. Ferreira ◽  
M. Walls ◽  
M. Da Cunha Belo

2008 ◽  
Vol 591-593 ◽  
pp. 55-60 ◽  
Author(s):  
E.P. Banczek ◽  
S.L. de Assis ◽  
Marize Varella de Oliveira ◽  
Waléria Silva de Medeiros ◽  
Luiz Carlos Pereira ◽  
...  

In this work, porous titanium samples processed by powder metallurgy and coated with biomimetic coatings, obtained during different periods of immersion in a simulated body fluid (SBF), were tested for corrosion resistance in a phosphate buffer solution (PBS). Uncoated samples were also tested for comparison. The corrosion resistance of both types of titanium samples was evaluated by electrochemical impedance spectroscopy and potentiodynamic polarisation curves. The electrochemical results indicated the formation of a surface film on the porous Ti samples with immersion in the SBF solution and this biomimetic film increased their corrosion resistance. This film helps osteointegration besides increasing corrosion resistance.


2011 ◽  
Vol 284-286 ◽  
pp. 1764-1769 ◽  
Author(s):  
Vitalijs Lakevics ◽  
Janis Locs ◽  
Dagnija Loca ◽  
Valentina Stepanova ◽  
Liga Berzina-Cimdina ◽  
...  

Sorption experiments of bovine serum albumin (BSA) on hydroxyapatite (HAp) ceramic granules, prepared at three temperatures 900°C, 1000°C and 1150°C were performed at room temperature 18,6 °C and phosphate buffer, pH 5,83; 6.38 and 7,39. Thermal treatment contributed to the decrease of bovine serum albumin immobilization indicating that sorption process depended on HAp ceramics specific surface area and pH values of phosphate buffer solution. However, it was confirmed that granule size was also an important parameter for bovine serum albumin adsorption. As a result of these experiments, the most appropriate adsorption conditions and phosphate buffer pH values influence on to BSA sorption were analyzed.


2000 ◽  
Vol 63 (6) ◽  
pp. 703-708 ◽  
Author(s):  
MARCY A. WISNIEWSKY ◽  
BONITA A. GLATZ ◽  
MARK L. GLEASON ◽  
CHERYLL A. REITMEIER

The objectives of this study were to determine if washing of whole apples with solutions of three different sanitizers (peroxyacetic acid, chlorine dioxide, or a chlorine-phosphate buffer solution) could reduce a contaminating nonpathogenic Escherichia coli O157:H7 population by 5 logs and at what sanitizer concentration and wash time such a reduction could be achieved. Sanitizers were tested at 1, 2, 4, 8, and 16 times the manufacturer's recommended concentration at wash times of 5, 10, and 15 min. Whole, sound Braeburn apples were inoculated with approximately 1 × 108 or 7 × 106 CFU per apple, stored for 24 h, then washed with sterile water (control) or with sanitizers for the prescribed time. Recovered bacteria were enumerated on trypticase soy agar. Washing with water alone reduced the recoverable population by almost 2 logs from the starting population; this can be attributed to physical removal of organisms from the apple surface. No sanitizer, when used at the recommended concentration, reduced the recovered E. coli population by 5 logs under the test conditions. The most effective sanitizer, peroxyacetic acid, achieved a 5-log reduction when used at 2.1 to 14 times its recommended concentration, depending on the length of the wash time. The chlorine-phosphate buffer solution reduced the population by 5 logs when used at 3 to 15 times its recommended concentration, depending on wash time. At no concentration or wash time tested did chlorine dioxide achieve the 5-log reduction.


2007 ◽  
Vol 26-28 ◽  
pp. 937-940 ◽  
Author(s):  
Dong Jin Kim ◽  
Hyuk Chul Kwon ◽  
Seong Sik Hwang ◽  
Hong Pyo Kim

Alloy 600 is used as a material for a steam generator tubing in pressurized water reactors(PWR) due to its high corrosion resistance under a PWR environment. In spite of its corrosion resistance, a stress corrosion cracking(SCC) has occurred on the primary side as well as the secondary side of a tubing. It is known that a SCC is related to the electrochemical behaviors of an anodic dissolution and a passivation of a bare surface of metals and alloys. Therefore in the present work, the passive oxide films on Alloy 600 have been investigated as a function of the solution temperature by using a potentiodynamic polarization, electrochemical impedance spectroscopy and a TEM, equipped with EDS. Moreover the semiconductive property was evaluated by using the Mott-Schottky relation. It was found that the passivity depends on the chemical composition and the densification of the oxide film rather than the oxide thickness. As the solution temperature of 0.5M H3BO3 increased, the thickness of the passive film increased but the oxide resistance of the passive film was decreased, indicating that the measured current in the passive region of the potentiodynamic curve is closely related to the stability of the passive film rather than the oxide thickness. It was found that the oxide films were composed of an outer oxide layer with a lower resistance and an inner oxide layer with a relatively higher resistance. From the Mott-Schottky relation, the oxide formed at 300oC showed a p-type semiconductor property unlike the n-type oxide films up to 250oC.


2018 ◽  
Vol 10 (11) ◽  
pp. 1362-1371 ◽  
Author(s):  
Mallappa Mahanthappa ◽  
Nagaraju Kottam ◽  
Shivaraj Yellappa

The simultaneous electroanalysis of acetaminophen (AC), guanine (G) and adenine (A) was successfully achieved on the zinc sulphide nanoparticles-modified carbon paste electrode (ZnS NPs/CPE) in phosphate buffer solution (PBS).


Author(s):  
Amitava Dutta ◽  
Apurba Kumar Santra ◽  
Ranjan Ganguly

Abstract We present a detailed numerical analysis of electrophoresis induced concentration of a bio-analyte facilitated by temperature gradient focusing in a phosphate buffer solution via Joule heating inside a converging-diverging microchannel. The purpose is to study the effects of frequency of AC field and channel width variation on the concentration of target analyte. We tune the buffer viscosity, conductivity and electrophoretic mobility of the analyte such that the electrophoretic velocity of the analyte locally balances the electroosmotic flow of the buffer, resulting in a local build-up of the analyte concentration in a target region. An AC field is superimposed on the applied DC field within the microchannel in such a way that the back pressure effect is minimized, resulting in minimum dispersion and high concentration of the target analyte. Axial transport of fluorescein-Na in the phosphate buffer solution is controlled by inducing temperature gradient through Joule heating. The technique leverages the fact that the buffer's ionic strength and viscosity depends on temperature, which in turn guides the analyte transport. A numerical model is proposed and a finite element-based solution of the coupled electric field, mass, momentum, energy and species equations are carried out. Simulation predict peak of 670-fold concentration of fluorescein-Na is achieved. The peak concentration is found to increase sharply as the channel throat width, while the axial spread of concentrated analyte increases at lower frequency of AC field. The results of the work may improve the design of micro concentrator.