Age, Sex, and Repeated Measures Effects on NASA’s “Cognition” Test Battery in STEM Educated Adults

2020 ◽  
Vol 91 (1) ◽  
pp. 18-25 ◽  
Author(s):  
Grace Lee ◽  
Tyler M. Moore ◽  
Mathias Basner ◽  
Jad Nasrini ◽  
David R. Roalf ◽  
...  

BACKGROUND: Cognition is a neurocognitive test battery created at the University of Pennsylvania and adapted by the National Aeronautics and Space Administration (NASA). It comprises 10 neurocognitive tests that examine multiple domains, and has been validated in a normative sample of STEM-educated adults and compared to NASA’s WinSCAT battery.METHODS: The purpose of this study was to follow the original sample to assess Cognition and WinSCAT’s test-retest reliability and age, sex, and test-retest interval effects on performance.RESULTS: Performance on both Cognition and WinSCAT decreased with age but improved with repeated administration due to practice effects, and men had higher scores than women on tasks that required vigilant attention, spatial reasoning, and risk-taking behaviors. Assessment of test-retest reliability showed intraclass coefficients for efficiency ranging from 0.417 to 0.810, reflecting the broad nature of constructs assessed by Cognition.DISCUSSION: Results largely matched predictions, with some counter-intuitive results for test-retest reliability interval.Lee G, Moore TM, Basner M, Nasrini J, Roalf DR, Ruparel K, Port AM, Dinges DF, Gur RC. Age, sex, and repeated measures effects on NASA’s “Cognition” Test Battery in STEM educated adults. Aerosp Med Hum Perform. 2020; 91(1):18–25.

2014 ◽  
Vol 42 (8) ◽  
pp. 2000-2005 ◽  
Author(s):  
Yusuke Nakayama ◽  
Tracey Covassin ◽  
Philip Schatz ◽  
Sally Nogle ◽  
Jeff Kovan

2022 ◽  
Vol 50 (1) ◽  
pp. 030006052110692
Author(s):  
Rong-San Jiang ◽  
Jing-Jie Wang ◽  
Kai-Li Liang ◽  
Kai-Hsiang Shih

Objective To evaluate the validity and test–retest reliability of the novel ‘TIB’ Olfactory Test Device (TIB) and to determine its normative values. Methods The study stratified the study subjects into normosmic, hyposmic and anosmic groups according to their olfactory function. The olfactory function of the subjects was evaluated using both the traditional Chinese version of the University of Pennsylvania of Smell Identification Test (UPSIT-TC) and the TIB. The normosmic group was used to retest with the UPSIT-TC and TIB at an inter-test interval of at least 7 days. The cut-off scores of TIB among the three different groups were determined by receiver operating characteristic curve analysis. Results This study enrolled 180 subjects: 60 in each group. The mean scores of TIB were 44.1 for the normosmic group, 27.5 for the hyposmic group and 10.9 for the anosmic group. The TIB scores were significantly different across the three groups. There was a significant correlation between the first and second TIB tests ( r = 0.506). The cut-off scores were 41 for normosmic subjects and 24 for hyposmic subjects. Conclusion The validity and test–retest reliability results suggest that the TIB is an appropriate olfactory test for the Taiwanese population.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Yanzhi Bi ◽  
Xin Hou ◽  
Jiahui Zhong ◽  
Li Hu

AbstractPain perception is a subjective experience and highly variable across time. Brain responses evoked by nociceptive stimuli are highly associated with pain perception and also showed considerable variability. To date, the test–retest reliability of laser-evoked pain perception and its associated brain responses across sessions remain unclear. Here, an experiment with a within-subject repeated-measures design was performed in 22 healthy volunteers. Radiant-heat laser stimuli were delivered on subjects’ left-hand dorsum in two sessions separated by 1–5 days. We observed that laser-evoked pain perception was significantly declined across sessions, coupled with decreased brain responses in the bilateral primary somatosensory cortex (S1), right primary motor cortex, supplementary motor area, and middle cingulate cortex. Intraclass correlation coefficients between the two sessions showed “fair” to “moderate” test–retest reliability for pain perception and brain responses. Additionally, we observed lower resting-state brain activity in the right S1 and lower resting-state functional connectivity between right S1 and dorsolateral prefrontal cortex in the second session than the first session. Altogether, being possibly influenced by changes of baseline mental state, laser-evoked pain perception and brain responses showed considerable across-session variability. This phenomenon should be considered when designing experiments for laboratory studies and evaluating pain abnormalities in clinical practice.


2021 ◽  
Vol 75 (Supplement_2) ◽  
pp. 7512500023p1-7512500023p1
Author(s):  
Shu-Chun Lee ◽  
Yi-Ching Wu ◽  
David Leland Roberts ◽  
Kuang-Pei Tseng ◽  
Wen-Yin Chen

Abstract Date Presented 04/19/21 The Social Cognition Screening Questionnaire–Taiwan version (SCSQT) was designed to assess multiple domains of social cognition in people with schizophrenia in Taiwan. The SCSQT contains five subscales and provides estimates of the core domains of mentalizing and social perception and an overall social cognition score. Our validation of SCSQT indicated that the SCSQT had good test–retest reliability, acceptable random measurement error, and negligible practice effects. Primary Author and Speaker: Shu-Chun Lee Additional Authors and Speakers: Trudy Mallinson Contributing Authors: Alison M. Cogan, Ann Guernon, Katherine O'Brien, and Piper Hansen


2021 ◽  
pp. 1-9
Author(s):  
Adam J. Wells ◽  
Bri-ana D.I. Johnson

Context: The Dynavision D2™ Mode A test (ModeA) is a 1-minute reaction time (RT) test commonly used in sports science research and clinical rehabilitation. However, there is limited data regarding the effect of repeated testing (ie, training) or subsequent periods of no testing (ie, detraining) on test–retest reliability and RT performance. Therefore, the purpose of this study was to examine the test–retest reliability, training, and detraining effects associated with the D2™ ModeA test. Design: Repeated measures/reliability. Methods: Twenty-four recreationally active men and women completed 15 training sessions consisting of 2 ModeA tests per session (30 tests). The participants were then randomized to either 1 or 2 weeks of detraining prior to completing 15 retraining sessions (30 tests). The training and retraining periods were separated into 10 blocks for analysis (3 tests per block). The number of hits (hits) and the average RT per hit (AvgRT) within each block were used to determine RT performance. Intraclass correlation coefficients, SEM, and minimum difference were used to determine reliability. Repeated-measures analysis of variance/analysis of covariance were used to determine training and detraining effects, respectively. Results: The ModeA variables demonstrated excellent test–retest reliability (intraclass correlation coefficient2,3 > .93). Significant improvements in hits and AvgRT were noted within training blocks 1 to 5 (P < .05). No further improvements in RT performance were noted between training blocks 6 through 10. There was no effect of detraining period on RT. The RT performance was not different between blocks during retraining. Conclusions: It appears that 15 tests are necessary to overcome the training effect and establish reliable baseline performance for the ModeA test. Detraining for 1 to 2 weeks did not impact RT performance. The authors recommend that investigators and clinicians utilize the average of 3 tests when assessing RT performance using the D2 ModeA test.


2002 ◽  
Vol 95 (3_suppl) ◽  
pp. 1295-1300 ◽  
Author(s):  
Nikolaos Tsigilis ◽  
Helen Douda ◽  
Savvas P. Tokmakidis

The purpose of this study was to examine the rest-retest reliability of the Eurofit motor fitness tests performed by university students. A total of 98 undergraduate students who were enrolled in physical education departments in Greece participated (29 men aged 19.5 ± 2.7 hr. and 66 women aged 19, 4 ± 2.7 yr.). ALL Eurofit motor fitness tests and anthropometric measurements were obtained twice with one week between the two measurements, Intraclass correlation coefficient indicated satisfactory coefficients above .70 for most tests. The only exception was the plate-tapping test which yielded a low value ( R = .57). Further, the majority of the Eurofit test battery fitted well within the 95% confidence interval, and only three Eurofit motor fitness test items (flamingo balance, plate tapping, and sit-ups) presented a confidence limit below the value of .70, These findings indicated that the Eurofit test battery yielded reliable data for undergraduate students. However, modifications should be considered to improve the reliability of certain test items, for application to undergraduates.


2021 ◽  
Vol 12 ◽  
Author(s):  
Céline Hochstrasser ◽  
Sarah Rieder ◽  
Ursina Jufer-Riedi ◽  
Marie-Noëlle Klein ◽  
Anthony Feinstein ◽  
...  

ObjectiveThe objective of this study was to validate the computerized Symbol Digit Modalities Test (c-SDMT) in a Swiss pediatric cohort, in comparing the Swiss sample to the Canadian norms. Secondly, we evaluated sex effects, age-effects, and test–retest reliability of the c-SDMT in comparison to values obtained for the paper and pencil version of the Symbol Digit Modalities Test (SDMT).MethodsThis longitudinal observational study was conducted in a single-center setting at the University Children’s Hospital of Bern. Our cohort consisted of 86 children (45 male and 41 female) aged from 8 to 16 years. The cohort included both healthy participants (n = 38) and patients (n = 48) hospitalized for a non-neurological disease. Forty eight participants were assessed during two testing sessions with the SDMT and the c-SDMT.ResultsTest–retest reliability was high in both tests (SDMT: ICC = 0.89, c-SDMT: ICC = 0.90). A reliable change index was calculated for the SDMT (RCIp = −3.18, 14.01) and the c-SDMT (RCIp = −5.45, 1.46) corrected for practice effects. While a significant age effect on information processing speed was observed, no such effect was found for sex. When data on the c-SDMT performance of the Swiss cohort was compared with that from a Canadian cohort, no significant difference was found for the mean time per trial in any age group. Norm values for age groups between 8 and 16 years in the Swiss cohort were established.ConclusionNorms for the c-SDMT between the Swiss and the Canadian cohort were comparable. The c-SDMT is a valid alternative to the SDMT. It is a feasible and easy to administer bedside tool due to high reliability and the lack of motor demands.


Author(s):  
Hannah Keppler ◽  
Sofie Degeest ◽  
Bart Vinck

Purpose The objective of the current study was to investigate the short-term test–retest reliability of contralateral suppression (CS) of click-evoked otoacoustic emissions (CEOAEs) using commercially available otoacoustic emission equipment. Method Twenty-three young normal-hearing subjects were tested. An otoscopic evaluation, admittance measures, pure-tone audiometry, measurements of CEOAEs without and with contralateral acoustic stimulation (CAS) to determine CS were performed at baseline ( n = 23), an immediate retest without and with refitting of the probe (only CS of CEOAEs; n = 11), and a retest after 1 week ( n = 23) were performed. Test–retest reliability parameters were determined on CEOAE response amplitudes without and with CAS, and on raw and normalized CS indices between baseline and the other test moments. Results Repeated-measures analysis of variance indicated no random or systematic changes in CEOAE response amplitudes without and with CAS, and in raw and normalized CS indices between the test moments. Moderate-to-high intraclass correlation coefficients with mostly high significant between-subjects variability between baseline and each consecutive test moment were found for CEOAE response amplitude without and with CAS, and for the raw and normalized CS indices. Other reliability parameters deteriorated between CEOAE response amplitudes with CAS as compared to without CAS, between baseline and retest with probe refitting, and after 1 week, as well as for frequency-specific raw and normalized CS indices as compared to global CS indices. Conclusions There was considerable variability in raw and normalized CS indices as measured using CEOAEs with CAS using commercially available otoacoustic emission equipment. More research is needed to optimize the measurement of CS of CEOAEs and to reduce influencing factors, as well as to make generalization of test–retest reliability data possible.


Sign in / Sign up

Export Citation Format

Share Document