scholarly journals Air Conditioning System using Air Cycle Machine (ACM) A Qualitative Validation

The work is aimed to replace conventional refrigerants used in air cooling system with Air Cycle Machine (ACM). Commercial Air-conditioners uses the refrigerants (Freon-Gas cycle) to remove the indoor air from the room. Freon leakage causes health problems such as respiratory ailments, heart attack and circulatory collapse. Air conditioning systems made based on desiccants. Refrigerant poisoning results in Throat swelling, loss of vision, blood vomiting, blood in the stool, severe abdominal pain and even death is possible. This can be overcome by using air cycle cooling process instead of Freon as a phase changing material. Air Cycle Machine is the system used in aircraft cabin pressurization and cooling system which does not uses refrigerants in the cooling process. The analytical work carried out in this paper is to study the air conditioning system using Air Cycle Machine and investigate the air flow inside the room by giving the various inlet temperatures and the inlet velocity of the Air-conditioner. ANSYS-FLUENT 16.0 is used for the analytical study. A cabin enclosure was modeled and analyzed for different inlet temperatures and velocities and out coming cool air spread nature for the given conditions have been observed. The qualitative results of this study clearly evident the usage of Air Cycle Machine (ACM) is prominently reduces the room temperature than the refrigerant system and spreads the cool air throughout the enclosed room makes a comfortable environment and this would not leads to any health hazards. Thus this study is certain to use Air Cycle Machine (ACM) for the cabin cooling system rather than refrigerants.

2019 ◽  
Vol 6 (3) ◽  
pp. 80-85
Author(s):  
Denis Igorevich Smagin ◽  
Konstantin Igorevich Starostin ◽  
Roman Sergeevich Savelyev ◽  
Anatoly Anatolyevich Satin ◽  
Anastasiya Romanovna Neveshkina ◽  
...  

One of the ways to achieve safety and comfort is to improve on-board air conditioning systems.The use of air cooling machine determines the air pressure high level at the point of selection from the aircraft engine compressor. Because of the aircraft operation in different modes and especially in the modes of small gas engines, deliberately high stages of selection have to be used for ensuring proper operation of the refrigeration machine in the modes of the aircraft small gas engines. Into force of this, most modes of aircraft operation have to throttle the pressure of the selected stage of selection, which, together with the low efficiency of the air cycle cooling system, makes the currently used air conditioning systems energy inefficient.A key feature of the architecture without air extraction from the main engines compressors is the use of electric drive compressors as a source of compressed air.A comparative analysis of competing variants of on-board air conditioning system without air extraction from engines for longrange aircraft projects was performed at the Moscow Aviation Institute (National Research University).The article deals with the main approaches to the decision-making process on the appearance of a promising aircraft on-board air conditioning system at the stage of its conceptual design and formulated the basic requirements for the structure of a complex criterion at different life cycle stages.The level of technical and technological risk, together with a larger installation weight, will require significant costs for development, testing, debugging and subsequent implementation, but at the same time on-board air conditioning system scheme without air extraction from the engines will achieve a significant increase in fuel efficiency at the level of the entire aircraft.


2018 ◽  
Vol 931 ◽  
pp. 920-925
Author(s):  
Zohrab Melikyan ◽  
Naira Egnatosyan ◽  
Siranush Egnatosyan

Centralized air conditioning systems are widely used in buildings at present. In these conditioners, the outside air gets required temperature, humidity, purity, and other features, necessary for creating comfort microclimate in inside areas of houses, and by the help of fans and air ducts the processed air moves to all rooms of a building. As a result, the creation and maintenance of comfort conditions in buildings become complicated and expensive activity. From this point of view, it is becoming more expedient to install local air conditioners in each room instead of single central one for the whole building. For this reason new local air conditioner is developed.


2020 ◽  
Vol 38 (7A) ◽  
pp. 984-991
Author(s):  
Krar M. Kuder ◽  
Hashim A. Hussein ◽  
Ali H. Numan

The present research paper is on photovoltaic air conditioning system using the direct drive method. The experimental system setup arranged in Iraq at Al-taje site at longitude 44.34 and latitude 33.432 during the summer season inside a room. The proposed off-grid system consists of an array of photovoltaic, battery used to store power, PWM (pulse width modulation) charge controller, and DC air cooler. During the examination of the system, proven success of this new type(dc air conditioner ) of client urges Iraq warm conditions as an alternative type used instead of the prevailing types of air conditioners (AC air conditioner )in Iraq which consume large amounts of electrical energy and gets a cooling system for the room full working on solar energy.                                                                                                                


Energies ◽  
2020 ◽  
Vol 13 (21) ◽  
pp. 5719
Author(s):  
JiHyun Hwang ◽  
Taewon Lee

The recent expansion of the internet network and rapid advancements in information and communication technology are expected to lead to a significant increase in power consumption and the number of data centers. However, these data centers consume a considerable amount of electric power all year round, regardless of working days or holidays; thus, energy saving at these facilities has become essential. A disproportionate level of power consumption is concentrated in computer rooms because air conditioners in these rooms are required to operate throughout the year to maintain a constant indoor environment for stable operation of computer equipment with high-heat release densities. Considerable energy-saving potential is expected in such computer rooms, which consume high levels of energy, if an outdoor air-cooling system and air conditioners are installed. These systems can reduce the indoor space temperature by introducing a relatively low outdoor air temperature. Therefore, we studied the energy-saving effect of introducing an outdoor air-cooling system in a computer room with a disorganized arrangement of servers and an inadequate air conditioning system in a research complex in Korea. The findings of this study confirmed that annual energy savings of up to approximately 40% can be achieved.


Energies ◽  
2020 ◽  
Vol 13 (22) ◽  
pp. 6145
Author(s):  
Yuan-Yuan Lou ◽  
Ben-Yuan Cai ◽  
Yun-Ze Li ◽  
Jia-Xin Li ◽  
En-Hui Li

The space scientific payload rack is a multifunctional experimental platform, and the requirements of the environmental temperature index are different for diversified experimental modules inside. The air cooling system is an important part of the rack thermal control system. A new type of air cooling system with small size and flexible arrangement is proposed in this paper, that is, micro air ducts with pinhole-sized air vents. The rack physical models of new and traditional air cooling modes are established, respectively. The numerical simulation of the inner air flow is carried out by Ansys Fluent CFD software (Ansys Inc., Canonsburg, PA, USA), which verifies that compared with the traditional method, the temperature field and flow field of the new air cooling method are more uniform, and the heat sources located at the edge of the rack can also be cooled better.


2014 ◽  
Vol 699 ◽  
pp. 828-833 ◽  
Author(s):  
Sumeru ◽  
Markus ◽  
Farid Nasir Ani ◽  
Henry Nasution

Air conditioning system consumes approximately 50% of the total energy consumption of buildings. Split-type air conditioner is the most widely used in residential and commercial buildings. As a result, enhancement on the performance of the air conditioners will yield a significant energy savings. The use of ejector as an expansion device on the split-type air conditioners is one method to increase the system performance. Exergy analysis on a split-type air conditioner uses an ejector as an expansion device at room and outdoor temperatures of 24 °C and 34 °C, respectively, yielded the percentage of exergy reduction up to 40.6%. Also, the exergy losses on in the compressor had the highest impact on the performance improvement of the split-type air conditioner.


2014 ◽  
Vol 672-674 ◽  
pp. 54-60 ◽  
Author(s):  
Ting Xiang Jin ◽  
Xiao Feng Xu

As coal, oil, natural gas and other non-renewable energy consumption and increasing energy demand, the utilization of solar energy as a new energy is greatly enhanced. In this work, a grid connected photovoltaic solar air conditioning system is designed, mainly comprised of solar panel, controller, inverter, room air conditioner and other parts. Air conditioning systems rely mainly on solar photovoltaic power; achieve the effect of energy conservation and environmental protection. The experimental result indicates that the system can achieve stable operation and the utilization of solar energy driving air conditioning system to save electricity. This air conditioning system is compared with the ordinary air conditioning system, SEER can increase 10.6 ~ 29.4%, HSPF can increase 6.25 ~ 18.5%.


Author(s):  
A. Anthony Adeyanju ◽  
K. Manohar

Thermoelectric devices use the Peltier effect which creates a heat flux between the junctions of two different types of materials. The thermoelectric module also referred to as a heat pump transfers heat from one side to the other when a DC current is applied. This study carried out the theoretical and experimental analysis of a thermoelectric air conditioning system. A prototype thermoelectric air conditioner of 286 W cooling capacity was built and a testing enclosure made from plywood and Styrofoam was also constructed in order to validate the theoretical result with an experimentation. It was discovered that thermoelectric air conditioning took 4 minutes to reach its desired temperature of 22℃ whereas the standard air conditioning system (Refrigeration Cycle) took 20 minutes to cool to a room temperature. Economically it was also discovered that thermoelectric air conditioning system is 50% cheaper than the refrigeration cycle air conditioning systems. The thermoelectric air conditioner has cheaper maintenance and greater estimated life span of 7 years more than the refrigeration air conditioner. This is because the air conditioner that operates on the refrigeration cycle uses a rotating compressor while the thermoelectric air conditioner uses thermometric module.


2019 ◽  
Vol 124 ◽  
pp. 01024
Author(s):  
Y. V. Vankov ◽  
A. K. Al–Okbi ◽  
M. H. Hasanen

The energy saving issues are becoming necessary worldwide, as excessive consumption of energy leads to the consumption of a larger amount of fuel, increases environmental pollution and negatively affects the ozone layer. In Iraq, in particular, the demand for central air conditioning systems and home air conditioners with high electrical capacity has become increasingly clear in the recent years. Air conditioning systems within residential and public buildings, as well as government facilities became a necessity for good internal comfort, which was driven by desertification, high temperature, air pollution and increased population, resulting in increased consumption of electric power and pressing of power plants. Aiming at usage of renewable energy sources, the proposed system uses solar collectors as auxiliary solar thermal compressors and integrate them with air conditioning systems. The proposed solution will increase the cooling system efficiency, reduce electricity consumption and pollution.


Author(s):  
Ahmed Almogbel ◽  
Fahad Alkasmoul ◽  
Zaid Aldawsari ◽  
Jaber Alsulami ◽  
Ahmed Alsuwailem

AbstractInterest for air-conditioning systems (ACs) has exponentially expanded worldwide throughout the most recent couple of decades. Countries with booming economies including Saudi Arabia report high growth of sales of room air conditioners. With the expanded (GDP) and warming climates, interest for room air-conditioning systems is required to additionally increment. Meeting the expanded need for electricity energy will be a challenge. Expanded utilization of energy-efficient air conditioners impactsly affects lowering the electricity demand. In an ordinary AC, the blower runs at a fixed speed and is either ON or OFF. In an inverter AC, the compressor is consistently on; however, power drawn relies upon the demand for cooling. The speed of the compressor is adjusted appropriately. In this paper, the energy consumption of non-inverter and an inverter AC of the same capacity was assessed in an average office room, under comparative operating conditions, to find the differences in the energy saving, Carbon Dioxide (CO2) emission, and power consumption of air conditioner. Energy consumption was measured for about 108 days, which is from July 16th to October 31st, 24/7, and compared. The experiment is conducted with the same conditions and same capacity air conditioners (18,000 BTU). Results show that the day-by-day normal vitality utilization, the inverter will save up to 44% of electrical consumption compared to a non-inverter of 3471 kWh/year and 6230 kWh/year respectively. Furthermore, the Total Equivalent Warming Impact (TEWI) analysis shows that inverters can save 49% of CO2 emissions.


Sign in / Sign up

Export Citation Format

Share Document