scholarly journals Ultrasound-Guided Percutaneous Thermal Ablation of Hepatic Focal Nodular Hyperplasia——A Multicenter Retrospective Study

Author(s):  
Xuan Yu ◽  
Jiandong Chang ◽  
Dezhi Zhang ◽  
Qiang Lu ◽  
Songsong Wu ◽  
...  

Background and Aim: To evaluate the clinical effect of ultrasound (US)-guided percutaneous thermal ablation of hepatic focal nodular hyperplasia (FNH).Methods: A retrospective analysis of the clinical data of patients undergoing US-guided percutaneous thermal ablation of FNH from November 2008 to August 2021 at five medical centers in China was conducted.Results: A total of 53 patients were included (26 males and 27 females). The mean age was 35.1 ± 10.8 years. Sixty-five lesions (46 solitary cases and 7 cases with multiple lesions) were included, 70.8% (46/65) of which were located in the right liver lobe. The mean tumor length was 2.9 ± 1.5 cm. All patients successfully completed the ablation treatment. Immediate postoperative imaging showed that the primary technical success rate was 94.3% (50/53). Two patients underwent ablation 3 and 6 months after the primary ablation, and the secondary technical success rate was 100% (2/2). The incidence of complications was 3.8% (2/53). Imaging follow-up was conducted regularly after ablation, and no residual lesion enlargement or tumor recurrence was observed during the follow-up period. The technique efficacy rate was 98.1% (52/53).Conclusion: US-guided percutaneous thermal ablation is a safe and effective treatment for FNH of the liver.

Author(s):  
Ying Wei ◽  
Cheng-zhong Peng ◽  
Shu-rong Wang ◽  
Jun-feng He ◽  
Li-li Peng ◽  
...  

Abstract Purpose To evaluate the effectiveness and safety of thermal ablation for primary hyperparathyroidism (pHPT). Materials and Methods From January 2015 to March 2020, data pertaining to patients who received thermal ablation for pHPT at 4 centers were retrospectively analyzed. The median follow-up duration was 18.1months (IQR: 6.5-42.2 months). A cure referred to the reestablishment of normal values of serum calcium and intact parathyroid hormone (iPTH) throughout the entire follow-up period, at least more than 6 months. The technical success, effectiveness, and safety of treatment were analyzed. Results 119 patients (mean age, 57.2 ± 16.3 years; 81 female) with 134 parathyroid nodules were enrolled. The mean maximum diameter of the parathyroid glands was 1.6 ± 0.9 cm. Ninety-six patients underwent microwave ablation (MWA), and 23 patients underwent radiofrequency ablation (RFA). The technical success rate was 98.3% and the cure rate was 89.9%. Significant differences were found in the maximum diameter between the cured patients and the patients who did not undergo ablation of the target lesions. Except the cases with pHPT nodules<0.6cm in diameter, the cure rate was 95%. There were no difference in cure rates at 6 months between the MWA and RFA (MWA vs. RFA, 90.6% vs. 87.0%; χ2=0.275, p = 0.699). The volume reduction rate of the ablation zone was 94.6% at 12 months. The complication rate was 6.7% (8/119). Except one patient with persistent voice impairment, other symptoms were spontaneously resolved within six months. Conclusion Thermal ablation was effective and safe for pHPT.


2020 ◽  
Vol 2 (4) ◽  
Author(s):  
Nabeeha Mohy-ud-din ◽  
Gursimran S Kochhar

Abstract Background Strictures are a common complication for patients with inflammatory bowel disease. Endoscopic stricturotomy (ESt) is a novel procedure for treatment of these strictures. Methods A chart review was performed for patients with strictures who underwent ESt. Results Eleven patients were included in the study and the total number of strictures treated was 12. The mean length of the strictures was 10.25 ± 4.36 mm. Technical success was achieved in 92% (n = 11) of the procedures. Postprocedural bleeding occurred in 9% (n = 1) of patients, and none of the patients had complications of infection or perforation. Conclusions ESt is a safe technique with high technical success rate.


2018 ◽  
Vol 2018 ◽  
pp. 1-7
Author(s):  
Hideki Kamada ◽  
Hideki Kobara ◽  
Naohito Uchida ◽  
Kiyohito Kato ◽  
Takayuki Fujimori ◽  
...  

Background. Endoscopic transpapillary gallbladder stenting (ETGBS) is an effective procedure for treating high-risk patients with acute cholecystitis and severe comorbidities. However, the efficacy of ETGBS for recurrent cholecystitis (RC) remains unclear. This study aimed to explore its efficacy in patients with RC for whom cholecystectomy is contraindicated because of its high surgical risk.Methods. Data on 19 high-risk patients who had undergone ETGBS for RC after initial conservative therapy in our institution between June 2006 and May 2012 were retrospectively examined. The primary outcome was the clinical success rate, which was defined as no recurrences of acute cholecystitis after ETGBS until death or the end of the follow-up period. Secondary outcomes were technical success rate and adverse events (AEs).Results. The clinical success rate of ETGBS was 100%, the technical success rate 94.7%, and AE rate 5%: one patient developed procedure-related mild acute pancreatitis. The clinical courses of all patients were as follows: four died of nonbiliary disease, and the remaining 15 were subsequently treated conservatively. The median duration of follow-up was 14.95 months (range 3–42 months).Conclusions. ETGBS is an effective alternative for managing RC in high-risk patients with severe comorbidities.


2020 ◽  
Vol 2020 ◽  
pp. 1-16 ◽  
Author(s):  
Aleksandra Pekacka

Introduction. Retinoblastoma is the most common primary intraocular neoplasm in children. With the advances in medicine, the armamentarium of available treatment modalities has grown. Intraarterial chemotherapy is a relatively new treatment method with promising outcomes. The purpose of this literature review is to evaluate its role in the management of retinoblastoma. Methods. A systematic online search was conducted using Ovid Embase and Ovid Medline. The final results included 23 studies. The studies were published between 2011 and 2019. The studies evaluated the technical success rate of IAC, globe salvage rate, and ocular and systemic complications, as well as the occurrence of deaths, metastasis, and secondary neoplasms. In total, 1827 eyes with retinoblastoma were analysed. The follow-up was between 0 and 252 months. Results. Overall globe retention rate ranged from 30% to 100%. Sixteen out of 23 studies reported ocular salvage between 60 and 80%. Eyelid oedema and erythema were the most commonly reported ocular complications following IAC. The most common systemic complications included nausea, vomiting, and neutropenia. Metastases and deaths were reported in 6 out of 23 studies. Three studies reported the development of secondary neoplasms. The technical success rate of IAC procedure ranged from 91% to 100%. Discussion. The studies have shown that IAC is a safe and effective treatment for advanced retinoblastoma, especially group D. It allows to save the globe without compromising patients’ survival. Local and systemic complications are acceptable. The role of IAC in less advanced tumours is yet to be established. Future work should focus on conducting larger prospective studies with longer follow-up. Multiple novel therapies for the management of retinoblastoma are currently being tested, including angiogenic inhibitors and targeted agents. The results seem to be promising. Future advances require a further in-depth understanding of unique genetics of retinoblastoma and complex interactions between tumour cells and their microenvironment.


2020 ◽  
Author(s):  
Yonghua Bi ◽  
Jindong Li ◽  
Liangliang Bai ◽  
Xinwei Han ◽  
Jianzhuang Ren

Abstract Background: Endoscopic removal is the most common method for removal of tracheal stents. Few studies have reported the technique of fluoroscopy-guided stent removal for tracheal fistula and tracheal stenosis. We aimed to study the safety and efficacy of fluoroscopy-guided stent removal as well as the optimal duration for stent usage.Methods: We conducted a retrospective analysis of 152 patients who underwent fluoroscopy-guided stent removal from January 2011 to June 2017. Reasons for stent implantation were tracheal fistula in 85 patients (TF group), and tracheal stenosis in 67 patients (TS group). All patients underwent tracheal CT scans before stent removal and during follow up. The technical success rate, complications, and survival rate were compared between the two groups.Results: The technical success rate of stent removal was 98.9% and 97.4%, respectively for the TF and TS group. Removal was routine for half of patients, and in the remainder, excessive granulation tissue was the common indications for stent removal, which was found after stenting at 142.1±25.9 days in the TF group, and at 89.9±15.0 day in the TS group. The total incidence of complications was 21.1% and 22.4%, respectively, for the TF and TS groups. Perioperative death occurred in one patient in the TF group, and two patients in the TS group. Recurrence of fistula or stenosis requiring re-stenting was the most comment complication in both groups. The 0.5-, 3-, 6-year survival rates were 90.3%, 59.6%, and 36.1% for TF group, and 80.4%, 75.7%, 75.7% for TS group.Conclusions: Fluoroscopic removal of tracheal stents is safe and effective for both tracheal fistula and tracheal stenosis, with no significant difference in outcomes. Recurrence of fistula or stenosis requiring re-stenting was the most common complication.


2020 ◽  
pp. 026835552097348
Author(s):  
Chang-Ming Wang ◽  
Shi-Lu Zhao ◽  
Qi-Chen Feng ◽  
Shuo Gai ◽  
Xuan Li

Objectives The present study was designed to assess outcomes of patients undergone radiofrequency ablation (RFA) for their incompetent perforator veins (IPVs) with ClosureFast stylets. Methods Data of 165 IPVs in 138 limbs of 117 consecutive patients between July 2017 to Nov. 2019 were retrospectively reviewed. Primary endpoints (technical success rate, complications) and secondary endpoints (VCSS) were analyzed. Results The immediate technical success rate was 100%. There were no major complications. The rate of ecchymosis and induration was 5.8%. 129/165 IPVs in 79.5% (93/117) patients had achieved sonographic evaluation at 1 year followed-up, in which 3 perforators were recanalized. VCSS scores at pre-operation and 1-year follow-up were 5.77 ± 1.88 and 2.70 ± 1.39, respectively ( t= 29.644, P= .000). Conclusions In conclusion, RFA is safe and effective for the treatment of IPVs. At the 1-year follow-up, the RFA of IPVs showed a low recanalization rate and had a satisfactory improvement on VCSS.


2019 ◽  
Vol 25 (5) ◽  
pp. 484-490 ◽  
Author(s):  
Aysun Erbahceci Salik ◽  
Hatem H Selcuk ◽  
Hasanagha Zalov ◽  
Fatih Kilinc ◽  
Musa Cirak ◽  
...  

Purpose The aim of this retrospective study is to evaluate medium-term results of undersized balloon angioplasty and stenting for symptomatic high-grade (70–99%) stenosis of a major intracranial artery with Enterprise stent. Methods This study included 68 consecutive symptomatic (recurrent transient ischemic attack (TIA) or ischemic stroke under dual antiplatelet treatment) patients with high-grade (70–99%) stenosis of a major intracranial artery who were endovascularly treated with undersized balloon angioplasty and Enterprise stent deployment between July 2012 and December 2017. Primary outcomes were any stroke or death within 30 days after procedure. Secondary outcomes were technical success rates, stroke and restenosis during the follow-up period. Results A total of 68 lesions in 68 patients (mean age: 62 ± 7 years) were treated with a technical success rate of 99%. The degree of pre-procedural stenosis was 92 ± 6% and dropped to 12 ± 10% after stent deployment. No patient developed any stroke or death during the periprocedural period. Intracranial hemorrhage was observed in 1 (1.5%) patient. In 60 (88%) patients with available imaging follow-up in-stent restenosis was observed in 2 patients. Mean follow-up period was 22 ± 17 months (range 6–72) and none of the patients experienced recurrent TIA or stroke during the follow-up period. Conclusion In this retrospective single-center study undersized balloon angioplasty and deployment of a self-expandable stent with relatively low radial force was safe and effective for endovascular treatment of high-grade intracranial arterial stenosis with high technical success rate, low periprocedural complication rates and favorable medium-term follow-up results.


Medicina ◽  
2006 ◽  
Vol 43 (6) ◽  
pp. 447
Author(s):  
Nerijus Aleksynas ◽  
Rytis Kaupas

Objective. To assess prospectively the first experience of subintimal angioplasty of superficial femoral artery occlusions. Patients and methods. Within a period of 36 months, 45 patients with 45 chronic occlusions in superficial femoral artery were treated at Kaunas University of Medicine Hospital. Results. The technical success rate was 84.4%, and four failures were treated by conventional surgery. The following complications occurred: one hematoma at the arterial puncture site, one artery spasm, and two distal embolizations. The mean length of occlusions was 14.2±1.4 cm. The mean ankle-brachial index improved from 0.41±0.15 to 0.81±0.04 after successful subintimal angioplasty (P<0.001). Primary assisted patency rates were 94.7%, 92.1%, 84.2%, 81.6%, and 81.6% at 1, 3, 6, 12, and 24 months, respectively. The limb salvage rates were 100% and 97.8% at 1–3 and 6–12–24 months, respectively. There were no treatmentrelated amputations. Conclusions. Subintimal angioplasty of occluded superficial femoral artery is a safe and minimally invasive procedure with a high initial technical success rate, low complication rate, and good early results, and in case of failure, subsequent surgery can be performed.


Neurosurgery ◽  
2011 ◽  
Vol 68 (4) ◽  
pp. 856-866 ◽  
Author(s):  
Martin H. Pham ◽  
Rudy J. Rahme ◽  
Omar Arnaout ◽  
Michael C. Hurley ◽  
Richard A. Bernstein ◽  
...  

Abstract BACKGROUND: Carotid and vertebral artery dissections are a leading cause of stroke in young individuals. OBJECTIVE: To examine the published safety and efficacy of endovascular stenting for extracranial artery dissection. METHODS: We conducted a systematic review of the literature to identify all cases of endovascular management of extracranial carotid and vertebral artery dissections. RESULTS: For carotid dissections, our review yielded 31 published reports including 140 patients (153 vessels). Reported etiologies were traumatic (48%, n = 64), spontaneous (37%, n = 49), and iatrogenic (16%, n = 21). The technical success rate of stenting was 99%, and the procedural complication rate was 1.3%. Mean angiographic follow-up was 12.8 months (range, 2-72 months) and revealed in-stent stenosis or occlusion in 2% of patients. Mean clinical follow-up was 17.7 months (range, 1-72 months), and neurological events were seen in 1.4% of patients. For vertebral artery dissections, our review revealed 8 reports including 10 patients (12 vessels). Etiologies were traumatic (60%, n = 6), spontaneous (20%, n = 2), and iatrogenic (20%, n = 2). There was a 100% technical success rate. The mean angiographic follow-up period was 7.5 months (range, 2-12 months). No new neurological events were reported during a mean clinical follow-up period of 26.4 months (range, 3-55 months). CONCLUSION: Endovascular management of extracranial arterial dissection continues to evolve. Current experience shows that this treatment option is safe and technically feasible. Prospective randomized trials compared with medical management are needed to further elucidate the role of stenting.


2021 ◽  
Vol 55 (4) ◽  
pp. 361-366
Author(s):  
Masashi Shimohira ◽  
Keiichi Nagai ◽  
Kengo Ohta ◽  
Yusuke Sawada ◽  
Keita Nakayama ◽  
...  

Introduction: Transcatheter arterial embolization is the first-line treatment for visceral artery pseudoaneurysms (VAPAs); however, the intraprocedural rupture of pseudoaneurysms is an important complication. The present study was performed to evaluate the safety of embolization for VAPAs, including the incidence of intraprocedural rupture. Methods: Among 56 consecutive patients with 57 VAPAs who underwent treatment between April 2009 and October 2020, 46 patients with 47 VAPAs underwent embolization. Complications related to embolization including intraprocedural rupture, the technical success rate, and clinical outcomes were evaluated. Complications that required extended hospitalization, an advanced level of care, or resulted in permanent adverse sequelae or death were classified as major complications, while the remainder were considered to be minor. Technical success was defined as the completion of embolization. Results: The intraprocedural rupture of pseudoaneurysms occurred in 3 out of 47 VAPAs treated with embolization (6%) and resulted in minor complications. One liver abscess requiring drainage was regarded as a major complication (2%). Focal infarction after embolization was observed as a minor complication in 20 cases. Complications occurred in 24 out of 47 cases (51%), comprising one major complication (2%) and 23 minor complications (48%). The technical success rate was 100% (47/47). Fifty-three out of 56 patients (95%) were alive in a median follow-up period of 18 months (range: 2 days-137 months). Conclusions: Embolization is safe and useful for the treatment of VAPAs; however, the intraprocedural rupture of pseudoaneurysms may occur, and, thus, care is needed during this procedure.


Sign in / Sign up

Export Citation Format

Share Document