scholarly journals Impedance Modeling and Analysis of Medium-Frequency Oscillation Caused by VSC-HVDC Connected to Local Weak Grid and DFIG-Based Wind Farms

2021 ◽  
Vol 9 ◽  
Author(s):  
Kun Sun ◽  
Wei Yao ◽  
Cai Yan ◽  
Jinyu Wen

In the northwest of China, a strategy to transmit the wind-thermal–bundled power from the local grid and doubly fed induction generator (DFIG)–based wind farms through a voltage source converter–based HVDC (VSC-HVDC) can be widely applied. However, since the local grid is usually weak, a new type of electrical oscillation in the medium-frequency region may occur in the sending-end converter (SEC) of VSC-HVDC with PQ-control. The mechanism of this oscillation caused by the interaction between the DFIG, local grid, and SEC is not entirely understood. In this study, the sequence impedance model of the sending-end converter (SEC) of VSC-HVDC with the PQ-control outer loop and PLL is derived with the explicit analytic expression, and then, the oscillation mechanism is explored based on the intuitive analysis of the system impedance frequency characteristics. Compared with the subsynchronous oscillation (SSO) caused by the DFIG or power inverter, the theoretical analysis shows that this medium-frequency oscillation (MFO) mainly originates from the SEC due to its negative damping effect between about 100 and 200 Hz. In addition, the impact of the system controller parameters and operating conditions of the DFIG, local grid, and SEC on the oscillation characteristics is analyzed in detail. Finally, the correctness of the theoretical analysis is validated by time-domain simulation.

2014 ◽  
Vol 2014 ◽  
pp. 1-6 ◽  
Author(s):  
Kai Liao ◽  
Zheng-you He ◽  
Bin Sun

Large-scale offshore wind farms are integrated with onshore ac grids through the voltage source converter based high voltage direct current (VSC-HVDC) transmission system. The impact on the stability of the ac grids will be significant. The small signal model of a wind farm connected with voltage source converter based dc transmission system is studied in this paper. A suitable model for small signal stability analysis is presented. The control system of wind generator and the HVDC system has also been modeled in this model for small signal stability analysis. The impact of the control parameters on the network stability is investigated.


Energies ◽  
2021 ◽  
Vol 14 (11) ◽  
pp. 3097
Author(s):  
Roberto Benato ◽  
Antonio Chiarelli ◽  
Sebastian Dambone Sessa

The purpose of this paper is to highlight that, in order to assess the availability of different HVDC cable transmission systems, a more detailed characterization of the cable management significantly affects the availability estimation since the cable represents one of the most critical elements of such systems. The analyzed case study consists of a multi-terminal direct current system based on both line commutated converter and voltage source converter technologies in different configurations, whose availability is computed for different transmitted power capacities. For these analyses, the matrix-based reliability estimation method is exploited together with the Monte Carlo approach and the Markov state space one. This paper shows how reliability analysis requires a deep knowledge of the real installation conditions. The impact of these conditions on the reliability evaluation and the involved benefits are also presented.


Author(s):  
Anjana Jain ◽  
R. Saravanakumar ◽  
S. Shankar ◽  
V. Vanitha

Abstract The variable-speed Permanent Magnet Synchronous Generator (PMSG) based Wind Energy Conversion System (WECS) attracts the maximum power from wind, but voltage-regulation and frequency-control of the system in standalone operation is a challenging task A modern-control-based-tracking of power from wind for its best utilization is proposed in this paper for standalone PMSG based hybrid-WECS comprising Battery Energy Storage System (BESS). An Adaptive Synchronous Reference Frame Phase-Locked-Loop (SRF-PLL) based control scheme for load side bi-directional voltage source converter (VSC) is presented for the system. MATLAB/Simulink model is developed for simulation study for the proposed system and the effectiveness of the controller for bi-directional-converter is discussed under different operating conditions: like variable wind-velocity, sudden load variation, and load unbalancing. Converter control scheme enhances the power smoothening, supply-load power-matching. Also it is able to regulate the active & reactive power from PMSG-BESS hybrid system with control of fluctuations in voltage & frequency with respect to varying operating conditions. Proposed controller successfully offers reactive-power-compensation, harmonics-reduction, and power-balancing. The proposed scheme is based on proportional & integral (PI) controller. Also system is experimentally validated in the laboratory-environment and results are presented here.


Energies ◽  
2020 ◽  
Vol 13 (14) ◽  
pp. 3554
Author(s):  
Naushath M. Haleem ◽  
Athula D. Rajapakse ◽  
Aniruddha M. Gole ◽  
Ioni T. Fernando

A selective fault clearing scheme is proposed for a hybrid voltage source converter (VSC)-line commutated converter (LCC) multi-terminal high voltage direct current (HVdc) transmission structure in which two small capacity VSC stations tap into the main transmission line of a high capacity LCC-HVdc link. The use of dc circuit breakers (dc CBs) on the branches connecting to VSCs at the tapping points is explored to minimize the impact of tapping on the reliability of the main LCC link. This arrangement allows clearing of temporary faults on the main LCC line as usual by force retardation of the LCC rectifier. The faults on the branches connecting to VSC stations can be cleared by blocking insulated gate bipolar transistors (IGBTs) and opening ac circuit breakers (ac CB), without affecting the main line’s performance. A local voltage and current measurement based fault discrimination scheme is developed to identify the faulted sections and pole(s), and trigger appropriate fault recovery functions. This fault discrimination scheme is capable of detecting and discriminating short circuits and high resistances faults in any branch well before 2 ms. For the test grid considered, 6 kA, 2 ms dc CBs can easily facilitate the intended fault clearing functions and maintain the power transfer through healthy pole during single-pole faults.


Energies ◽  
2020 ◽  
Vol 13 (3) ◽  
pp. 560
Author(s):  
Juanjuan Sun ◽  
Hui Wang ◽  
Xiaomin Zhu ◽  
Qian Pu

When the power source of a voltage source converter (VSC) station at the sending end solely depends on wind power generation, the station is operating in an islanding mode. In this case, the power fluctuation of the wind power will be entirely transmitted to the receiving-end grid. A self-regulation scheme of power fluctuation is proposed in this paper to solve this problem. Firstly, we investigated the short-time variability characteristic of the wind power in a multi-terminal direct-current (MTDC) project in China. Then we designed a virtual frequency (VF) control strategy at the VSC station based on the common constant voltage constant frequency (CVCF) control of VSC station. By cooperating with the primary frequency regulation (PFR) control at the wind farms, the self-regulation of active power pooling at the VSC station was realized. The control parameters of VF and PFR control were carefully settled through the steady-state analysis of the MTDC grid. The self-regulation effect had been demonstrated by a twenty-four-hour simulation. The results showed that the proposed scheme could effectively smoothen the power fluctuation.


Energies ◽  
2020 ◽  
Vol 13 (13) ◽  
pp. 3316 ◽  
Author(s):  
Dong Wang ◽  
Xiaojie Zhang ◽  
Lei Yang ◽  
Yunhui Huang ◽  
Wei Huang ◽  
...  

Recent studies show that the loss of stability for a voltage-source converter (VSC) in weak-grid connection is largely related to its synchronization unit, i.e., the phase-locked loop (PLL). This paper studies the synchronization stability of a system comprised by two VSCs in parallel connection to a weak grid. A reduced transfer function based small-signal model, which can allow for the interactions between PLL and converter outer power controls, is first proposed. Then, an improved net damping criterion is used to analyze the damping and stability characters of such system under various operating conditions and different controller configurations. Compared to the conventional net damping criterion, the used criterion has wider applicability in terms of stability judgment. Case studies show that the studied system tends to be unstable at weak-grid or heavy-loading conditions. The instability can be in the form of oscillations or monotonic divergence, in which, the latter is more likely to occur for the converters without grid voltage regulation capabilities. Besides, the net damping-based sensitivity studies can provide guidance on control tuning or design for stability enhancement. Detailed model-based time domain simulations are conducted to verify the analysis results.


2013 ◽  
Vol 860-863 ◽  
pp. 1633-1637
Author(s):  
Jing Lv ◽  
Te Te Hu ◽  
Zhe Bin He ◽  
Eric Hu

The trans-critical CO2 refrigeration cycle involving a regenerative process is analyzed in this paper. The thermodynamic performance of the cycles with regeneration and without regeneration has been compared. The optimal circumstance for the regenerative process set in the trans-critical CO2 cycle is given. The impact of the regeneration on the performance of the system under difference operating conditions is also discussed in this article.


2021 ◽  
Vol 9 (3B) ◽  
Author(s):  
Yasser Ahmed Elshrief ◽  
◽  
A. D. Asham ◽  
Belal Ahmed Abozalam ◽  
Sameh Abd-Elhaleem ◽  
...  

Distributed generation (DG) has reformed the meaning of traditional generation of power from large-scale to small-scale generation. The main issue of connecting the DG to the utility grid is the detection of unintended islanding. This paper shows the impact of the islanding phenomenon in the case of grid-connected photovoltaic arrays and how to develop a convenient technique to detect this phenomenon. A passive islanding detection algorithm is proposed for all types of DGs by varying and analyzing the DC-link voltage for voltage source converter in the photovoltaic inverter. The proposed algorithm is applied on the low and medium voltage scales. Furthermore, a comparison for applying the proposed technique with resistance load on the two scales is presented. In addition, the proposed technique for anti-islanding protection is performed and compared with a lot of techniques such as underfrequency, overfrequency, and rate of change of frequency according to the detection time of islanding. The simulation results using MATLAB/ SIMULINK platform illustrate the effectiveness of the proposed method.


Theoretical review of various topologies of high voltage DC links in application to off shore wind forms has been studied and analysed. In addition to that, various types of high voltage DC links such as back to back, two terminal, multi-terminal systems has been covered under this study. The Line-Commutated Converters, Voltage Source Converter, Modular Multi-Level Converter as well as some of advanced hybrid high voltage DC topologies in application to off shore wind forms has been reviewed. This study covers complication arising from large-scale wind power generation. The review paper also points out the scope of future research in high voltage DC converters.