scholarly journals Individualized Determination of the Mechanical Fracture Environment After Tibial Exchange Nailing—A Simulation-Based Feasibility Study

2021 ◽  
Vol 8 ◽  
Author(s):  
Benedikt J. Braun ◽  
Marcel Orth ◽  
Stefan Diebels ◽  
Kerstin Wickert ◽  
Annchristin Andres ◽  
...  

Non-union rate after tibial fractures remains high. Apart from largely uncontrollable biologic, injury, and patient-specific factors, the mechanical fracture environment is a key determinant of healing. Our aim was to establish a patient-specific simulation workflow to determine the mechanical fracture environment and allow for an estimation of its healing potential. In a referred patient with failed nail-osteosynthesis after tibial-shaft fracture exchange nailing was performed. Post-operative CT-scans were used to construct a three-dimensional model of the treatment situation in an image processing and computer-aided design system. Resulting forces, computed in a simulation-driven workflow based on patient monitoring and motion capturing were used to simulate the mechanical fracture environment before and after exchange nailing. Implant stresses for the initial and revision situation, as well as interfragmentary movement, resulting hydrostatic, and octahedral shear strain were calculated and compared to the clinical course. The simulation model was able to adequately predict hardware stresses in the initial situation where mechanical implant failure occurred. Furthermore, hydrostatic and octahedral shear strain of the revision situation were calculated to be within published healing boundaries—accordingly the fracture healed uneventfully. Our workflow is able to determine the mechanical environment of a fracture fixation, calculate implant stresses, interfragmentary movement, and the resulting strain. Critical mechanical boundary conditions for fracture healing can be determined in relation to individual loading parameters. Based on this individualized treatment recommendations during the early post-operative phase in lower leg fractures are possible in order to prevent implant failure and non-union development.

Author(s):  
A. N. Bozhko

Computer-aided design of assembly processes (Computer aided assembly planning, CAAP) of complex products is an important and urgent problem of state-of-the-art information technologies. Intensive research on CAAP has been underway since the 1980s. Meanwhile, specialized design systems were created to provide synthesis of assembly plans and product decompositions into assembly units. Such systems as ASPE, RAPID, XAP / 1, FLAPS, Archimedes, PRELEIDES, HAP, etc. can be given, as an example. These experimental developments did not get widespread use in industry, since they are based on the models of products with limited adequacy and require an expert’s active involvement in preparing initial information. The design tools for the state-of-the-art full-featured CAD/CAM systems (Siemens NX, Dassault CATIA and PTC Creo Elements / Pro), which are designed to provide CAAP, mainly take into account the geometric constraints that the design imposes on design solutions. These systems often synthesize technologically incorrect assembly sequences in which known technological heuristics are violated, for example orderliness in accuracy, consistency with the system of dimension chains, etc.An AssemBL software application package has been developed for a structured analysis of products and a synthesis of assembly plans and decompositions. The AssemBL uses a hyper-graph model of a product that correctly describes coherent and sequential assembly operations and processes. In terms of the hyper-graph model, an assembly operation is described as shrinkage of edge, an assembly plan is a sequence of shrinkages that converts a hyper-graph into the point, and a decomposition of product into assembly units is a hyper-graph partition into sub-graphs.The AssemBL solves the problem of minimizing the number of direct checks for geometric solvability when assembling complex products. This task is posed as a plus-sum two-person game of bicoloured brushing of an ordered set. In the paradigm of this model, the brushing operation is to check a certain structured fragment for solvability by collision detection methods. A rational brushing strategy minimizes the number of such checks.The package is integrated into the Siemens NX 10.0 computer-aided design system. This solution allowed us to combine specialized AssemBL tools with a developed toolkit of one of the most powerful and popular integrated CAD/CAM /CAE systems.


2020 ◽  
Vol 22 (2) ◽  
pp. 619-636 ◽  
Author(s):  
Zbigniew Tyfa ◽  
Damian Obidowski ◽  
Krzysztof Jóźwik

AbstractThe primary objective of this research can be divided into two separate aspects. The first one was to verify whether own software can be treated as a viable source of data for the Computer Aided Design (CAD) modelling and Computational Fluid Dynamics CFD analysis. The second aspect was to analyze the influence of the Ventricle Assist Device (VAD) outflow cannula positioning on the blood flow distribution in the brain-supplying arteries. Patient-specific model was reconstructed basing on the DICOM image sets obtained with the angiographic Computed Tomography. The reconstruction process was performed in the custom-created software, whereas the outflow cannulas were added in the SolidWorks software. Volumetric meshes were generated in the Ansys Mesher module. The transient boundary conditions enabled simulating several full cardiac cycles. Performed investigations focused mainly on volume flow rate, shear stress and velocity distribution. It was proven that custom-created software enhances the processes of the anatomical objects reconstruction. Developed geometrical files are compatible with CAD and CFD software – they can be easily manipulated and modified. Concerning the numerical simulations, several cases with varied positioning of the VAD outflow cannula were analyzed. Obtained results revealed that the location of the VAD outflow cannula has a slight impact on the blood flow distribution among the brain supplying arteries.


2020 ◽  
Vol 133 (2) ◽  
pp. 521-529 ◽  
Author(s):  
Vivek P. Bodani ◽  
Gerben E. Breimer ◽  
Faizal A. Haji ◽  
Thomas Looi ◽  
James M. Drake

OBJECTIVEEndoscopic resection of third-ventricle colloid cysts is technically challenging due to the limited dexterity and visualization provided by neuroendoscopic instruments. Extensive training and experience are required to master the learning curve. To improve the education of neurosurgical trainees in this procedure, a synthetic surgical simulator was developed and its realism, procedural content, and utility as a training instrument were evaluated.METHODSThe simulator was developed based on the neuroimaging (axial noncontrast CT and T1-weighted gadolinium-enhanced MRI) of an 8-year-old patient with a colloid cyst and hydrocephalus. Image segmentation, computer-aided design, rapid prototyping (3D printing), and silicone molding techniques were used to produce models of the skull, brain, ventricles, and colloid cyst. The cyst was filled with a viscous fluid and secured to the roof of the third ventricle. The choroid plexus and intraventricular veins were also included. Twenty-four neurosurgical trainees performed a simulated colloid cyst resection using a 30° angled endoscope, neuroendoscopic instruments, and image guidance. Using a 19-item feedback survey (5-point Likert scales), participants evaluated the simulator across 5 domains: anatomy, instrument handling, procedural content, perceived realism, and confidence and comfort level.RESULTSParticipants found the simulator’s anatomy to be highly realistic (mean 4.34 ± 0.63 [SD]) and appreciated the use of actual instruments (mean 4.38 ± 0.58). The procedural content was also rated highly (mean 4.28 ± 0.77); however, the perceived realism was rated slightly lower (mean 4.08 ± 0.63). Participants reported greater confidence in their ability to perform an endoscopic colloid cyst resection after using the simulator (mean 4.45 ± 0.68). Twenty-three participants (95.8%) indicated that they would use the simulator for additional training. Recommendations were made to develop complex case scenarios for experienced trainees (normal-sized ventricles, choroid plexus adherent to cyst wall, bleeding scenarios) and incorporate advanced instrumentation such as side-cutting aspiration devices.CONCLUSIONSA patient-specific synthetic surgical simulator for training residents and fellows in endoscopic colloid cyst resection was successfully developed. The simulator’s anatomy, instrument handling, and procedural content were found to be realistic. The simulator may serve as a valuable educational tool to learn the critical steps of endoscopic colloid cyst resection, develop a detailed understanding of intraventricular anatomy, and gain proficiency with bimanual neuroendoscopic techniques.


2016 ◽  
Vol 5 (01) ◽  
pp. 4723 ◽  
Author(s):  
Bhusnure O. G.* ◽  
Gholve V. S. ◽  
Sugave B. K. ◽  
Dongre R. C. ◽  
Gore S. A. ◽  
...  

Many researchers have attempted to use computer-aided design (C.A.D) and computer-aided manufacturing (CAM) to realize a scaffold that provides a three-dimensional (3D) environment for regeneration of tissues and organs. As a result, several 3D printing technologies, including stereolithography, deposition modeling, inkjet-based printing and selective laser sintering have been developed. Because these 3D printing technologies use computers for design and fabrication, and they can fabricate 3D scaffolds as designed; as a consequence, they can be standardized. Growth of target tissues and organs requires the presence of appropriate growth factors, so fabrication of 3Dscaffold systems that release these biomolecules has been explored. A drug delivery system (D.D.S) that administrates a pharmaceutical compound to achieve a therapeutic effect in cells, animals and humans is a key technology that delivers biomolecules without side effects caused by excessive doses. 3D printing technologies and D. D. Ss have been assembled successfully, so new possibilities for improved tissue regeneration have been suggested. If the interaction between cells and scaffold system with biomolecules can be understood and controlled, and if an optimal 3D tissue regenerating environment is realized, 3D printing technologies will become an important aspect of tissue engineering research in the near future. 3D Printing promises to produce complex biomedical devices according to computer design using patient-specific anatomical data. Since its initial use as pre-surgical visualization models and tooling molds, 3D Printing has slowly evolved to create one-of-a-kind devices, implants, scaffolds for tissue engineering, diagnostic platforms, and drug delivery systems. Fuelled by the recent explosion in public interest and access to affordable printers, there is renewed interest to combine stem cells with custom 3D scaffolds for personalized regenerative medicine. Before 3D Printing can be used routinely for the regeneration of complex tissues (e.g. bone, cartilage, muscles, vessels, nerves in the craniomaxillofacial complex), and complex organs with intricate 3D microarchitecture (e.g. liver, lymphoid organs), several technological limitations must be addressed. Until recently, tablet designs had been restricted to the relatively small number of shapes that are easily achievable using traditional manufacturing methods. As 3D printing capabilities develop further, safety and regulatory concerns are addressed and the cost of the technology falls, contract manufacturers and pharmaceutical companies that experiment with these 3D printing innovations are likely to gain a competitive edge. This review compose the basics, types & techniques used, advantages and disadvantages of 3D printing


2021 ◽  
Vol 11 (6) ◽  
pp. 2852
Author(s):  
Maeruan Kebbach ◽  
Christian Schulze ◽  
Christian Meyenburg ◽  
Daniel Kluess ◽  
Mevluet Sungu ◽  
...  

The calculation of range of motion (ROM) is a key factor during preoperative planning of total hip replacements (THR), to reduce the risk of impingement and dislocation of the artificial hip joint. To support the preoperative assessment of THR, a magnetic resonance imaging (MRI)-based computational framework was generated; this enabled the estimation of patient-specific ROM and type of impingement (bone-to-bone, implant-to-bone, and implant-to-implant) postoperatively, using a three-dimensional computer-aided design (CAD) to visualize typical clinical joint movements. Hence, patient-specific CAD models from 19 patients were generated from MRI scans and a conventional total hip system (Bicontact® hip stem and Plasmacup® SC acetabular cup with a ceramic-on-ceramic bearing) was implanted virtually. As a verification of the framework, the ROM was compared between preoperatively planned and the postoperatively reconstructed situations; this was derived based on postoperative radiographs (n = 6 patients) during different clinically relevant movements. The data analysis revealed there was no significant difference between preoperatively planned and postoperatively reconstructed ROM (∆ROM) of maximum flexion (∆ROM = 0°, p = 0.854) and internal rotation (∆ROM = 1.8°, p = 0.917). Contrarily, minor differences were observed for the ROM during maximum external rotation (∆ROM = 9°, p = 0.046). Impingement, of all three types, was in good agreement with the preoperatively planned and postoperatively reconstructed scenarios during all movements. The calculated ROM reached physiological levels during flexion and internal rotation movement; however, it exceeded physiological levels during external rotation. Patients, where implant-to-implant impingement was detected, reached higher ROMs than patients with bone-to-bone impingement. The proposed framework provides the capability to predict postoperative ROM of THRs.


2021 ◽  
Vol 11 (9) ◽  
pp. 4057
Author(s):  
Leonardo Frizziero ◽  
Gian Maria Santi ◽  
Christian Leon-Cardenas ◽  
Giampiero Donnici ◽  
Alfredo Liverani ◽  
...  

The study of CAD (computer aided design) modeling, design and manufacturing techniques has undergone a rapid growth over the past decades. In medicine, this development mainly concerned the dental and maxillofacial sectors. Significant progress has also been made in orthopedics with pre-operative CAD simulations, printing of bone models and production of patient-specific instruments. However, the traditional procedure that formulates the surgical plan based exclusively on two-dimensional images and interventions performed without the aid of specific instruments for the patient and is currently the most used surgical technique. The production of custom-made tools for the patient, in fact, is often expensive and its use is limited to a few hospitals. The purpose of this study is to show an innovative and cost-effective procedure aimed at prototyping a custom-made surgical guide for address the cubitus varus deformity on a pediatric patient. The cutting guides were obtained through an additive manufacturing process that starts from the 3D digital model of the patient’s bone and allows to design specific models using Creo Parametric. The result is a tool that adheres perfectly to the patient’s bone and guides the surgeon during the osteotomy procedure. The low cost of the methodology described makes it worth noticing by any health institution.


2011 ◽  
Vol 109 ◽  
pp. 711-714
Author(s):  
Ying Jiang ◽  
Jie Liu

Secondary develop system can realize design automation of the common parts, so that software system can automatically inquire the chart and get data, then this could really release design personnel and improve the design efficiency. By secondary develop system of stirred tank users can respectively carry on the design according to their own needs. So secondary develop system has the function of automatic generation graphics, and can generate CAD drawings complying with the design requirement, so it reflected the intelligent performance of the design system. Secondary develop system is able to complete the automatic design of common parts, and can greatly improve the quality and efficiency of design, so it has very important use value. This design realizes the function of automatic graphics generation of transmission of stirred tank, and can generate structure design of common belt wheel.


2018 ◽  
Vol 9 (7) ◽  
pp. 92-99 ◽  
Author(s):  
Jacob E Vaughn ◽  
Ronit V Shah ◽  
Tarek Samman ◽  
Jacob Stirton ◽  
Jiayong Liu ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document