scholarly journals Numerical Study of the Improvement in Stability and Performance by Use of a Partial Vaned Diffuser for a Centrifugal Compressor Stage

2021 ◽  
Vol 11 (15) ◽  
pp. 6980
Author(s):  
Shuai Li ◽  
Yan Liu ◽  
Hongkun Li ◽  
Mohammad Omidi

The influence of different diffuser configurations on the flow stability and aerodynamic performance of a centrifugal compressor stage with a mass flow coefficient of 0.196 is numerically investigated. Research results show that the performance of a traditional full-height vaned diffuser (TVD) deteriorates rapidly, and a shroud-side partial vaned diffuser (SVD) displays better adaptability in off-design conditions. SVD can suppress the development of vortices generating at the diffuser leading-edge. Therefore, it can reduce the flow loss inside the stage and improve the flow stability of the stage at low mass flow rates. The unsteady analysis for TVD and SVD shows that the stall cell propagates at about 35.7% of impeller rotational speed in the semi-vaneless space and diffuser passages. Furthermore, the internal flow in TVD and SVD is studied by employing the proper orthogonal decomposition (POD) and dynamic mode decomposition (DMD) methods. The flow loss and instability mechanism in the stage are consequently revealed more comprehensively.

Author(s):  
James M. Sorokes ◽  
Jason A. Kopko

The paper addresses the use of a rib style (partial height) vaned diffuser to improve the flowfield downstream of a high flow coefficient centrifugal impeller. Empirical and analytical (3-D CFD) results are presented for both the original vaneless diffuser and the replacement rib configuration. Comparisons are made between the CFD results and the data obtained through single stage rig (SSTR) testing. Comments are offered regarding the qualitative and quantitative agreement between the empirical and analytical results.


2009 ◽  
Vol 131 (4) ◽  
Author(s):  
Isabelle Trébinjac ◽  
Pascale Kulisa ◽  
Nicolas Bulot ◽  
Nicolas Rochuon

Numerical and experimental investigations were conducted in a transonic centrifugal compressor stage composed of a backswept splittered unshrouded impeller and a vaned diffuser. The characteristic curves of the compressor stage resulting from the unsteady simulations and the experiments show a good agreement over the whole operating range. On the contrary, the total pressure ratio resulting from the steady simulations is clearly overestimated. A detailed analysis of the flow field at design operating point led to identify the physical mechanisms involved in the blade row interaction that underlie the observed shift in performance. Attention was focused on the deformation in shape of the vane bow shock wave due its interaction with the jet and wake flow structure emerging from the impeller. An analytical model is proposed to quantify the time-averaged effects of the associated entropy increase. The model is based on the calculation of the losses across a shock wave at various inlet Mach numbers corresponding to the moving of the jet and wake flow in front of the shock wave. The model was applied to the compressor stage performance calculated with the steady simulations. The resulting curve of the overall pressure ratio as a function of the mass flow is clearly shifted toward the unsteady results. The model, in particular, enhances the prediction of the choked mass flow.


Author(s):  
Isabelle Tre´binjac ◽  
Pascale Kulisa ◽  
Nicolas Bulot ◽  
Nicolas Rochuon

Numerical and experimental investigations were conducted in a transonic centrifugal compressor stage composed of a backswept splittered unshrouded impeller and a vaned diffuser. The characteristic curves of the compressor stage resulting from the unsteady simulations and the experiments show a good agreement over the whole operating range. On the contrary, the total pressure ratio resulting from the steady simulations is clearly overestimated. A detailed analysis of the flow field at design operating point led to identify the physical mechanisms involved in the blade row interaction that underlie the observed shift in performance. Attention was focused on the deformation in shape of the vane bow shock wave due its interaction with the jet and wake flow structure emerging from the impeller. An analytical model is proposed to quantify the time-averaged effects of the associated entropy increase. The model is based on the calculation of the losses across a shock wave at various inlet Mach numbers corresponding to the moving of the jet and wake flow in front of the shock wave. The model was applied to the compressor stage performance calculated with the steady simulations. The resulting curve of the overall pressure ratio as a function of the mass flow is clearly shifted towards the unsteady results. The model in particular enhances the prediction of the choked mass flow.


2013 ◽  
Vol 30 (2) ◽  
pp. 113-121 ◽  
Author(s):  
L. H. Jawad ◽  
S. Abdullah ◽  
R. Zulkifli ◽  
W. M. F. W. Mahmood

ABSTRACTThis paper is a numerical simulation that was made in the three-dimensional flow, carried out in a modified centrifugal compressor, having vaned diffuser stage, used as an auto-motive turbo charger. Moreover, the performance of the centrifugal compressor was dependent on the proper matching between compressor impeller and vaned diffuser, influencing significantly surge and the efficiency of centrifugal compressor stages. In addition, a modified compressor impeller, coupled with vane and vaneless diffuser, has been found to have similar internal flow patterns for both the vaneless and vaned diffuser design. The vaned diffuser effect has been paid particular attention in terms of better analysis where the diffuser was designed for high sub-sonic inlet conditions. Another aim of this research was to study and simulate the effect of vaned diffuser on the performance of a centrifugal compressor. The simulation was undertaken by using a commercial software, the so-called ANSYS CFX, to predict numerically the performance in terms of pressure ratio, poly tropic efficiency and mass flow rate for the centrifugal compressor stage. The results were generated from CFD and were analyzed for better understanding of the fluid flow through centrifugal compressor stage. Conclusively, it was observed that the effect of the vaned diffuser is to convert the kinetic energy into a high static pressure after analyzing the results of the simulation.


Author(s):  
Venkateswara Rao Pothuri ◽  
Venkata Ramana Murty Govindaraju ◽  
Venkata Rao Ganapathiraju

This paper describes the computational results on the performance of a centrifugal compressor stage with twisted vaned diffuser by varying the speed of the impeller and direction of twist for the diffuser vane. The centrifugal compressor stage configuration consists of a 2-D impeller (no twist is provided for the impeller vanes) with various configurations of diffusers. Diffuser configurations considered are Vaneless Diffuser (VLD), Low Solidity Vaned Diffuser (LSVD) and Twisted Vaned Diffuser (TVD). The analysis was carried at four different rotational speeds with corresponding mass flow rates of the impeller. 9° twist is given to the diffuser vane from hub to shroud by providing rotation at the leading edge, keeping the profile at hub as reference in the direction of rotation of the impeller and opposite to the direction of rotation of the impeller. The off-design cases considered includes operation at 80%, 90%, 110% and 120% of the design mass flow rate. CFD results are validated with experimental results for stages with VLD and LSVD for certain chosen performance parameters such as head coefficient, stage input power and exit flow angle. The computational results indicate that variations in impeller speed will cause changes in all significant performance parameters like the total pressure rise, power coefficient and efficiency of the stage and static pressure recovery coefficient of the diffuser. Contour plots were generated from CFD results and analyzed for better understanding of effect of rotational speed of the impeller on the performance of the centrifugal compressor. As a result of this study, it can be concluded that twisted vaned diffuser improves the performance in comparison to low solidity vaned diffuser for all the chosen impeller rotational speeds. The performance of the compressor stage is superior when diffuser vane twist is provided in the direction opposite to the rotation of impeller.


Author(s):  
Peng-Fei Zhao ◽  
Yan Liu ◽  
Xiao-Fang Wang

An appropriate diffuser following an impeller is critical to realize a high efficiency and a wide operating range for a centrifugal compressor stage. The purpose of this study is to investigate the effect of different types of vaned diffusers on a large mass flow coefficient centrifugal compressor stage performance under different operating conditions and to reveal the loss mechanisms in the vaned diffusers. Five vaned diffusers are studied. Flow fields and vortices in a conventional diffuser and a rib diffuser are first examined. Then, vortices and flow fields in three different tandem diffusers are analyzed in detail. For the three tandem diffusers, only circumferential position of first row vanes relative to the second row vanes is different. Results show that the stage with the conventional diffuser possesses the shortest operating range. The rib diffuser has less loss due to the weaker tip leakage vortex, while its static pressure recovery coefficient is lower, and the loss in the following return part is higher. Comparison results between the three tandem diffusers imply that when the trailing edge of the first row vane is close to the pressure surface of the second row vane, the stage with the tandem diffuser has a better performance. This is ascribed to the interaction of the tip leakage vortex and suction surface vortex, which decreases the total loss, especially reduces the loss induced by the suction surface vortex. When the trailing edge of the first row vanes is close to the suction surface of the second row vane, the loss is increased since the leading edge vortex has a large strength and surrounds the suction surface vortex. Therefore, the reasonable interaction of vortices in a tandem diffuser can bring a high performance of the centrifugal compressor.


2017 ◽  
Vol 140 (1) ◽  
Author(s):  
Lee Galloway ◽  
Stephen Spence ◽  
Sung In Kim ◽  
Daniel Rusch ◽  
Klemens Vogel ◽  
...  

The stable operating range of a centrifugal compressor stage of an engine turbocharger is limited at low mass flow rates by aerodynamic instabilities which can lead to the onset of rotating stall or surge. There have been many techniques employed to increase the stable operating range of centrifugal compressor stages. The literature demonstrates that there are various possibilities for adding special treatments to the nominal diffuser vane geometry, or including injection or bleed flows to modify the diffuser flow field in order to influence diffuser stability. One such treatment is the porous throat diffuser (PTD). Although the benefits of this technique have been proven in the existing literature, a comprehensive understanding of how this technique operates is not yet available. This paper uses experimental measurements from a high pressure ratio (PR) compressor stage to acquire a sound understanding of the flow features within the vaned diffuser which affect the stability of the overall compression system and investigate the stabilizing mechanism of the porous throat diffuser. The nonuniform circumferential pressure imposed by the asymmetric volute is experimentally and numerically examined to understand if this provides a preferential location for stall inception in the diffuser. The following hypothesis is confirmed: linking of the diffuser throats via the side cavity equalizes the diffuser throat pressure, thus creating a more homogeneous circumferential pressure distribution, which delays stall inception to lower flow rates. The results of the porous throat diffuser configuration are compared to a standard vaned diffuser compressor stage in terms of overall compressor performance parameters, circumferential pressure nonuniformity at various locations through the compressor stage and diffuser subcomponent analysis. The diffuser inlet region was found to be the element most influenced by the porous throat diffuser, and the stability limit is mainly governed by this element.


Author(s):  
A. Hildebrandt ◽  
T. Ceyrowsky

The present paper deals with the numerical and theoretical investigations of the effect of geometrical dimensions and 1D-design parameters on the impeller pressure slope of a transonic centrifugal compressor stage for industrial process application. A database being generated during the multi-objective and multi-point design process of a high flow coefficient impeller, comprising 545 CFD (Computational Fluid Dynamics) designs is investigated in off-design and design conditions by means of RANS (Reynolds Averaged Navier Stokes) simulation of an impeller with vaneless diffuser. For high flow coefficients of 0.16 < phi < 0.18, the CFD-setup has been validated against measurement data regarding stage and impeller performance taken from MAN test rig experimental data for a centrifugal compressor stage of similar flow coefficient. The paper aims at answering the question how classical design parameter, such as the impeller blade angle distribution, impeller suction diameter and camber line length affect the local and total relative diffusion and pressure slope towards impeller stall operation. A second order analysis of the CFD database is performed by cross-correlating the CFD data with results from impeller two-zone 1D modelling and a rapid loading calculation process by Stanitz and Prian. The statistical covariance of first order 1D-analysis parameters such as the mixing loss of the impeller secondary flow, the slip factor, impeller flow incidence is analyzed, thereby showing strong correlation with the design and off-design point efficiency and pressure slope. Finally, guide lines are derived in order to achieve either optimized design point efficiency or maximum negative pressure slope characteristics towards impeller stall operation.


Author(s):  
T. Ch. Siva Reddy ◽  
G. V. Ramana Murty ◽  
Prasad Mukkavilli ◽  
D. N. Reddy

Numerical simulation of impeller and low solidity vaned diffuser (LSD) of a centrifugal compressor stage is performed individually using CFX- BladeGen and BladeGenPlus codes. The tip mach number for the chosen study was 0.35. The same configuration was used for experimental investigation for a comparative study. The LSD vane is formed using standard NACA profile with marginal modification at trailing edge. The performance parameters obtained form numerical studies at the exit of impeller and the diffuser have been compared with the corresponding experimental data. These parameters are pressure ratio, polytropic efficiency and flow angle at the impeller exit where as the parameters those have been compared at the exit of diffuser are the static pressure recovery coefficient and the exit flow angle. In addition, the numerical prediction of the blade loading in terms of blade surface pressure distribution on LSD vane has been compared with the corresponding experimental results. Static pressure recovery coefficient and flow angle at diffuser exit is seen to match closely at higher flows. The difference at lower flows could be due to the effect of interaction between impeller and diffuser combinations, as the numerical analysis was done separately for impeller and diffuser and the effect of impeller diffuser interaction was not considered.