scholarly journals Research on Temperature Compensation Method in Crankshaft Online Measurement System

2021 ◽  
Vol 11 (16) ◽  
pp. 7558
Author(s):  
Tingting Gu ◽  
Xiaoming Qian ◽  
Peihuang Lou

The crankshaft online measurement system has realized the full inspection function with fast beats, at the same time it requires for high-precision measurement. Considering the effect of ambient temperature and temperature changes on measuring machine, the calibration part, the measured crankshaft and displacement sensor, a temperature compensation method is proposed. Firstly, relationship between calibration part and ambient temperature can be get through the zero calibration. Then use the material properties to obtain compensation values of the calibration part and the measured crankshaft part at different temperatures. Finally, the compensation parameters for displacement sensor can be obtained through the BP algorithm. The improved dragonfly algorithm (DA) is used to optimize the parameters of BP neural network algorithm. Experiments verify the effectiveness of IDA-BP for LVDT in temperature compensation. After temperature compensation, the error range of main journal radius is reduced from 0.0156 mm to 0.0028 mm, the residual error decreased from −0.0282 mm~+0.0018 mm to −0.0058 mm~−0.0008 mm. The influence of temperature changes on the measurement is reduced and measurement accuracy is improved through the temperature compensation method. The effectiveness of the method is proved.

Author(s):  
Ruiqi Ma ◽  
Guoqing Feng ◽  
Huilong Ren ◽  
Peng Fu ◽  
Shuang Wu ◽  
...  

Hull monitoring system with Fiber Bragg Grating (FBG) sensors increasingly receives people’s attentions. However, for the ship hull monitoring, the deformation of hull girder changes a lot as is subjected to a huge temperature variation. Therefore, the compensation method with only FBG temperature self-correction is not suitable for the hull monitoring sensors because no material thermal expansion effects are reasonably included. In this paper, the new compensation method of hull monitoring FBG sensor based on the sensor theory with both FBG temperature self-correction and steel thermal expansion effects correction is studied. The coupled compensation method suitable for hull monitoring sensor is obtained by theoretical derivation. As the comparison, the coupled compensation experiment was carried out. The results show that the relative error under the temperature compensation method is large in the case of drastic strain and temperature changes, and the correction results of the tested method will be closer to the true level.


2012 ◽  
Vol 10 (7) ◽  
pp. 1514-1516
Author(s):  
Yang Song ◽  
Jianpei Zhang ◽  
Lijie Li ◽  
Jing Yang ◽  
Chunyang Han ◽  
...  

1975 ◽  
Vol 53 (6) ◽  
pp. 679-685 ◽  
Author(s):  
J. B. Holter ◽  
W. E. Urban Jr. ◽  
H. H. Hayes ◽  
H. Silver ◽  
H. R. Skutt

Six adult white-tailed deer (Odocoileus virginianus borealis) were exposed to 165 periods of 12 consecutive hours of controlled constant ambient temperature in an indirect respiration calorimeter. Temperatures among periods varied from 38 to 0 (summer) or to −20C (fall, winter, spring). Traits measured were energy expenditure (metabolic rate), proportion of time spent standing, heart rate, and body temperature, the latter two using telemetry. The deer used body posture extensively as a means of maintaining body energy equilibrium. Energy expenditure was increased at low ambient temperature to combat cold and to maintain relatively constant body temperature. Changes in heart rate paralleled changes in energy expenditure. In a limited number of comparisons, slight wind chill was combatted through behavioral means with no effect on energy expenditure. The reaction of deer to varying ambient temperatures was not the same in all seasons of the year.


2013 ◽  
Vol 347-350 ◽  
pp. 197-200
Author(s):  
Yu Gong ◽  
Jing Cai Zhang ◽  
Hong Qi Liu

In this paper, research on measurement methods of hole during the parts online detection has been made. Both diameter and position of the hole are going to be detected in the same measurement system. In order to obtain higher accuracy and efficiency, a comparative analysis test of using the contact probes, the inductive sensor, the laser sensor, the forward and back lighting CCD imaging have been achieved. Results show that the contact measurement using inductive sensor is more suitable for the system, for the reason that it has higher reliability and efficiency.


Sensors ◽  
2018 ◽  
Vol 18 (11) ◽  
pp. 3685 ◽  
Author(s):  
Marcin Adamczyk ◽  
Paweł Liberadzki ◽  
Robert Sitnik

This paper presents the results of several studies concerning the effect of temperature on digital cameras. Experiments were performed using three different camera models. The presented results conclusively demonstrate that the typical camera design does not adequately take into account the effect of temperature variation on the device’s performance. In this regard, a modified camera design is proposed that exhibits a highly predictable behavior under varying ambient temperature and facilitates thermal compensation. A novel temperature compensation method is also proposed. This compensation model can be applied in almost every existing camera application, as it is compatible with every camera calibration model. A two-dimensional (2D) and three-dimensional (3D) application of the proposed compensation model is also described. The results of the application of the proposed compensation approach are presented herein.


Sign in / Sign up

Export Citation Format

Share Document