scholarly journals Cholera Rapid Diagnostic Tests for the Detection of Vibrio cholerae O1: An Updated Meta-Analysis

Diagnostics ◽  
2021 ◽  
Vol 11 (11) ◽  
pp. 2095
Author(s):  
Basilua Andre Muzembo ◽  
Kei Kitahara ◽  
Ayumu Ohno ◽  
Anusuya Debnath ◽  
Keinosuke Okamoto ◽  
...  

The rapid diagnosis of cholera contributes to adequate outbreak management. This meta-analysis assesses the diagnostic accuracy of cholera rapid tests (RDTs) to detect Vibrio cholerae O1. Methods: Systematic review and meta-analysis. We searched four databases (Medline, EMBASE, Google Scholar, and Web of Science up to 8 September 2021) for studies that evaluated cholera RDTs for the detection of V. cholerae O1 compared with either stool culture or polymerase chain reaction (PCR). We assessed the studies’ quality using the QUADAS-2 criteria. In addition, in this update, GRADE approach was used to rate the overall certainty of the evidence. We performed a bivariate random-effects meta-analysis to calculate the pooled sensitivity and specificity of cholera RDTs. Results: Overall, 20 studies were included in this meta-analysis. Studies were from Africa (n = 11), Asia (n = 7), and America (Haiti; n = 2). They evaluated eight RDTs (Crystal VC-O1, Crystal VC, Cholkit, Institut Pasteur cholera dipstick, SD Bioline, Artron, Cholera Smart O1, and Smart II Cholera O1). Using direct specimen testing, sensitivity and specificity of RDTs were 90% (95% CI, 86 to 93) and 86% (95% CI, 81 to 90), respectively. Cholera Sensitivity was higher in studies conducted in Africa [92% (95% CI, 89 to 94)] compared with Asia [82% (95% CI, 77 to 87)]. However, specificity [83% (95% CI, 71 to 91)] was lower in Africa compared with Asia [90% (95% CI, 84 to 94)]. GRADE quality of evidence was estimated as moderate. Conclusions: Against culture or PCR, current cholera RDTs have moderate sensitivity and specificity for detecting Vibrio cholerae O1.

Author(s):  
Beatrice Heim ◽  
Florian Krismer ◽  
Klaus Seppi

AbstractDifferential diagnosis of parkinsonian syndromes is considered one of the most challenging in neurology. Quantitative MR planimetric measurements were reported to discriminate between progressive supranuclear palsy (PSP) and non-PSP-parkinsonism. Several studies have used midbrain to pons ratio (M/P) and the Magnetic Resonance Parkinsonism Index (MRPI) in distinguishing PSP patients from those with Parkinson's disease. The current meta-analysis aimed to compare the performance of these measures in discriminating PSP from multiple system atrophy (MSA). A systematic MEDLINE review identified 59 out of 2984 studies allowing a calculation of sensitivity and specificity using the MRPI or M/P. Meta-analyses of results were carried out using random effects modelling. To assess study quality and risk of bias, the QUADAS-2 tool was used. Eight studies were suitable for analysis. The meta‐analysis showed a pooled sensitivity and specificity for the MRPI of PSP versus MSA of 79.2% (95% CI 72.7–84.4%) and 91.2% (95% CI 79.5–96.5%), and 84.1% (95% CI 77.2–89.2%) and 89.2% (95% CI 81.8–93.8%), respectively, for the M/P. The QUADAS-2 toolbox revealed a high risk of bias regarding the methodological quality of patient selection and index test, as all patients were seen in a specialized outpatient department without avoiding case control design and no predefined threshold was given regarding MRPI or M/P cut-offs. Planimetric brainstem measurements, in special the MRPI and M/P, yield high diagnostic accuracy for the discrimination of PSP from MSA. However, there is an urgent need for well-designed, prospective validation studies to ameliorate the concerns regarding the risk of bias.


2014 ◽  
Vol 2014 ◽  
pp. 1-11 ◽  
Author(s):  
Sheng-Li Yang ◽  
Xiefan Fang ◽  
Zao-Zao Huang ◽  
Xiang-Jie Liu ◽  
Zhi-Fan Xiong ◽  
...  

Objective. This review is to evaluate the diagnostic value of serum GPC3 for hepatocellular carcinoma (HCC) due to conflicting results reported.Methods. NCBI PubMed and Embase were comprehensively searched for studies that have used serum GPC3 level as a diagnostic index for HCC. The quality of the included studies was assessed. Subgroup analyses were conducted to evaluate the sensitivity and specificity of GPC3 as a HCC marker. Statistical analysis was performed with the software STATA version 12.0.Results. A total of 22 studies were included. The qualities of included studies were relatively poor. Among them, 18 studies have shown that serum GPC3 is a specific biomarker for HCC, and the pooled sensitivity and specificity of these studies were 69 and 93%, respectively. The other 4 studies have reported conflicting results, which were not caused by races, infection status of HBV and HCV, or assay reagents but due to one common experimental design of enrolling liver cirrhosis patients as control subjects.Conclusions. This meta-analysis indicates that serum GPC3 is elevated in HCC patients compared with healthy individuals, but more studies are needed to evaluate its effectiveness to differentially diagnose HCC and liver cirrhosis.


BMJ Open ◽  
2018 ◽  
Vol 8 (2) ◽  
pp. e018132 ◽  
Author(s):  
Carmen Phang Romero Casas ◽  
Marrissa Martyn-St James ◽  
Jean Hamilton ◽  
Daniel S Marinho ◽  
Rodolfo Castro ◽  
...  

ObjectivesTo undertake a systematic review and meta-analysis to evaluate the test performance including sensitivity and specificity of rapid immunochromatographic syphilis (ICS) point-of-care (POC) tests at antenatal clinics compared with reference standard tests (non-treponemal (TP) and TP tests) for active syphilis in pregnant women.MethodsFive electronic databases were searched (PubMed, EMBASE, CRD, Cochrane Library and LILACS) to March 2016 for diagnostic accuracy studies of ICS test and standard reference tests for syphilis in pregnant women. Methodological quality was assessed using QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies). A bivariate meta-analysis was undertaken to generate pooled estimates of diagnostic parameters. Results were presented using a coupled forest plot of sensitivity and specificity and a scatter plot.ResultsThe methodological quality of the five included studies with regards to risk of bias and applicability concern judgements was either low or unclear. One study was judged as high risk of bias for patient selection due to exclusion of pregnant women with a previous history of syphilis, and one study was judged at high risk of bias for study flow and timing as not all patients were included in the analysis. Five studies contributed to the meta-analysis, providing a pooled sensitivity and specificity for ICS of 0.85 (95% CrI: 0.73 to 0.92) and 0.98 (95% CrI: 0.95 to 0.99), respectively.ConclusionsThis review and meta-analysis observed that rapid ICS POC tests have a high sensitivity and specificity when performed in pregnant women at antenatal clinics. However, the methodological quality of the existing evidence base should be taken into consideration when interpreting these results.PROSPERO registration numberCRD42016036335.


2018 ◽  
Vol 12 (09) ◽  
pp. 700-705
Author(s):  
Mojtaba Bonyadian ◽  
Hamdallah Moshtaghi ◽  
Hanie Nadi

Introduction: The quality of drinking water has an important role in human health. This study was aimed to detect Escherichia. coli, Salmonella sp. and Vibrio cholerae from bottled drinking waters produced in Iran. Methodology: A total of 240 samples of bottled water of different brands were collected for testing between March 2015 to December 2015 in Shahrekord-Iran. Samples were examined by polymerase chain reaction (PCR) combined with culture methods for the detection of E. coli, Salmonella sp., and V. cholerae. Results: The results of PCR revealed that the uidA gene from E. coli, IpaB gene from Salmonella sp, and epsM gene from V. cholerae were detected in 6 (2.5%), 1 (0.4 %), 0 (0%) of the samples, respectively. But in culture methods, only E. coli 5 (2.1%) were isolated from the samples. The contamination with E. coli was significantly higher (P < 0.05) in water produced during the hot seasons than the cold seasons. Conclusions: This study confirmed the presence of Escherichia coli as the main microorganism in bottle drinking water in Iran. Also, our study showed that PCR can be used as a screening method for monitoring the enteric pathogens in drinking water.


Author(s):  
E.A. Moskvitina ◽  
E.G. Tyuleneva ◽  
A.V. Samorodova ◽  
V.D. Kruglikov ◽  
S.V. Titova

In this paper the degree of potential epidemic hazard (DPEH) is defined of surface water bodies utilized as the sources of centralized household water supply and for recreational purposes, with the consideration of their contamination by Vibrio cholerae O1 and O139 and the quality of wastewater discharged into surface water bodies, in 67 subjects of the Russian Federation. High and increased DPEH of surface water bodies in case of their contamination by V. cholerae O1 ctxA+ tcpA+, V. cholerae ctxA- tcpA+ and V. cholerae O1 and O139 ctxA- tcpA- implies the presence of both real and potential epidemiological risks of realisation of the water route of transmission of the infectious agent. DPEH of water bodies together with other data will be used for determination of the epidemic potential of an administrative territory.