scholarly journals Comparison of Root Surface Wear and Roughness Resulted from Different Ultrasonic Scalers and Polishing Devices Applied on Human Teeth: An In-Vitro Study

Healthcare ◽  
2020 ◽  
Vol 8 (1) ◽  
pp. 55
Author(s):  
Muhammed Bedir Mahiroglu ◽  
Erkut Kahramanoglu ◽  
Mustafa Ay ◽  
Leyla Kuru ◽  
Omer Birkan Agrali

The aim of the present study was to compare the root surface wear and roughness, resulted from the professional dental hygiene instruments, including ultrasonic dental scalers, rubber prophy cups, and nylon bristle brushes, on the extracted human mandibular incisor teeth. Teeth (n = 80) were randomly assigned into eight groups according to the applied scaler type (Ma = Magnetostrictive, Pi = Piezoelectric), degree of power (M = Medium, F = Full), and angulation (0° and 45°). In the second stage, the specimens (n = 40) were further divided into two groups according to the applied polishing device (nylon bristle brush or rubber prophy cup). Laser scanner and contact profilometer devices were used for the surface analysis. Both ultrasonic instruments tested in our study produced rougher surfaces when full power was used at a 0° angle (p < 0.01). The highest wear (0.82 ± 0.07 mm3) and roughness values (0.30 ± 0.01 µm) were detected in the PiF0 group. Polishing performed with a rubber prophy cup resulted in almost twice the wear as well as a smoother surface when compared to polishing performed with a nylon bristle brush (p < 0.001). Variations in the application parameters of ultrasonic scalers and the type of polishing instrument might lead to significantly different root-surface characteristics.

2006 ◽  
Vol 14 (2) ◽  
pp. 124-129 ◽  
Author(s):  
Fernanda Vieira Ribeiro ◽  
Renato Correa Viana Casarin ◽  
Francisco Humberto Nociti Júnior ◽  
Enilson Antônio Sallum ◽  
Antonio Wilson Sallum ◽  
...  

OBJECTIVE: The purpose of this study was to evaluate the root surface roughness after instrumentation with hand curette and diamond-coated sonic and universal ultrasonic tips. MATERIALS AND METHODS: Forty root surfaces of human teeth were randomly assigned to four treatment groups: control group (without instrumentation), curette instrumentation, ultrasonic instrumentation with universal tip and sonic instrumentation with diamond-coated tip. Each sample was instrumented with fifteen strokes. Before and after instrumentation, surface roughness was measured. In addition, the root surface topography was examined after treatment under the scanning electron microscope. RESULTS: Significant statistical differences (p <0.05) were observed when comparing the control group (0.48±0.07mm) to the treated groups (hand - 1.246±0.279mm, ultrasonic - 1.468±0.177mm and sonic instrumentation - 1.576±0.20mm). The highest roughness was produced by diamond-coated sonic tip and by ultrasonic universal tip (p >0.05). CONCLUSION: The diamond-coated tip with sonic scaler instrumentation and ultrasonic instrumentation produce similar root surface roughness, higher than curette instrumentation.


Author(s):  
Alexandra Stähli ◽  
Alex S. J. Schatt ◽  
Miro Stoffel ◽  
Sandor Nietzsche ◽  
Anton Sculean ◽  
...  

Abstract Objectives To investigate how scaling affects the penetration of microorganisms into dentinal tubules, how pulpal cells seeded into the pulp cavity respond to bacterial challenge, and how penetration and inflammatory response may depend on the bacterial composition. Materials and methods Root canals of 102 extracted human teeth underwent shaping and cleaning. Half of the teeth were subjected to scaling and root planing, the other half remained untreated. Teeth were exposed to either Streptococcus gordonii and Actinomyces oris or S. gordonii and Porphyromonas gingivalis for 10 weeks. Bacterial invasion was assessed in a depth of 1 mm to the root surface. Human pulpal cells were seeded into the cavities to assess the expression of interleukin-8 (IL-8), monocyte chemoattractant protein-1 (MCP-1), and matrix metalloproteinase-3 (MMP-3) by real-time polymerase chain reaction and immunoassay. Results The percentage of teeth with bacteria detected in dentine was higher when teeth received scaling than when they were untreated: 66.6% versus 44.4% when exposed to A. oris/S. gordonii, and 50% versus 25% when exposed to P. gingivalis/S. gordonii (p = 0.043). Scaling had no impact on IL-8 and MMP-3 expression in pulpal cells. P. gingivalis/S. gordonii caused higher levels of IL-8, MCP-1, and MMP-3 than A. oris/S. gordonii (p = 0.003, p = 0.011, p = 0.037). Conclusion Scaling supports the penetration of bacteria into the dentine of extracted human teeth. P. gingivalis may affect the immune response in pulpal cells. Clinical relevance Root surface debridement with hand instruments may facilitate bacterial penetration. Other kinds of mechanical instrumentation in this experimental setting should be investigated.


2012 ◽  
Vol 2012 ◽  
pp. 1-5 ◽  
Author(s):  
Blerim Kamberi ◽  
Donika Bajrami ◽  
Miranda Stavileci ◽  
Shuhreta Omeragiq ◽  
Fatmir Dragidella ◽  
...  

Aim. The purpose of this in vitro study was to assess the antimicrobial efficacy of Biopure MTAD against E. faecalis in contaminated root canals. Materials and Methods. Forty-two single rooted extracted human teeth were inoculated with E. faecalis and incubated for four weeks. The samples were divided in two control and five experimental groups irrigated with 1.5% sodium hypochlorite solution (NaOCl); 3% NaOCl; BioPure MTAD; 1.5% NaOCl/17% EDTA; or 3% NaOCl/17% EDTA. After a one-week incubation, complete disinfection was confirmed by the absence of turbidity in the incubation media. Dentin shavings were taken from samples with no turbidity to verify whether E. faecalis was present in dentin tubules. Results were analyzed statistically using Fisher's exact test, with the level of significance set at . Results. Statistical analysis of the data obtained at Day 7 and after dentin shaving analysis showed that BioPure MTAD had significantly greater antibacterial activity than 1.5% NaOCl, 1.5% NaOCl/17% EDTA and 3% NaOCl/17% EDTA. No significant difference was detected between MTAD and 3% NaOCl. Conclusions. These findings suggest that BioPure MTAD possesses superior bactericidal activity compared with NaOCl and EDTA against E. faecalis.


2007 ◽  
Vol 18 (1) ◽  
pp. 20-23 ◽  
Author(s):  
João Vicente Baroni Barbizam ◽  
Matheus Souza ◽  
Doglas Cecchin ◽  
Jakob Dabbel

The purpose of this in vitro study was to evaluate the ability of a silicon-based root canal sealer, compared to zinc oxide and eugenol and an epoxy resin-based sealers, for filling of simulated lateral canals. Thirty extracted single-rooted human teeth were selected, conventional access was made and the working length was established 1 mm from the apical foramen. Three simulated lateral canals, one in each root third (coronal, middle and apical) were prepared in both the mesial and distal surfaces of each tooth using a size 15 reamer adapted to a low-speed handpiece. Each root canal was instrumented using ProTaper rotary files up to file F3 at the working length, and then irrigated with 2.5% NaOCl followed by EDTA. The teeth were assigned to 3 groups (n=10), according to the root canal sealer: Roeko Seal (Group 1), Sealer 26 (group 2) and Grossman's sealer (Group 3). Gutta-percha cold lateral condensation technique was performed in all groups. Postoperative radiographs were taken and the images were projected for evaluation of the quality of lateral canal filling. Data were submitted to statistical analysis by Kruskal Wallis test at 5% significance level. The results showed that Grossman's sealer filled a larger number of lateral canals than Roeko Seal (p<0.05) and Sealer 26 (p<0.01). It may be concluded that Roeko Seal silicone-based root canal sealer was not as effective as the Grossman's sealer for filling of simulated lateral canals. The lateral canals localized in the apical third of the root were more difficult to be filled.


Author(s):  
Hardi Rajanbhai Shukla ◽  
Aditi Mathur ◽  
Neema Shetty ◽  
Barkha Makhijani ◽  
Balaji Manohar

Background: Biofilm removal is the central part of the etiotropic and maintenance phase of periodontal therapy. Commercially available injection water jets such as Prophy-Jet allows an efficient and convenient biofilm removal as an adjunct to mechanical periodontal therapy. But, due to the abrasive nature of traditionally used air polishing powders such as sodium bicarbonate, there is a continuous research going on for less abrasive materials. Aims: To compare the effectiveness of air polishing using glycine powder and chlorhexidine acetate powder on tooth surface as compared to ultrasonic scaling and also to evaluate the time taken for stain removal. Materials and Methods: Thirty fully erupted, single rooted teeth extracted due to poor periodontal prognosis were used in this in-vitro study. The sample teeth were divided into 3 equal groups and stained in coffee solution. The test Groups A and B underwent air-polishing with glycine powder and chlorhexidine acetate powder respectively. Group C was control group and underwent ultrasonic scaling. Time taken for stain removal was recorded. The sample teeth were also evaluated under a stereo-microscope and digital micrometer preprocedurally and post-procedurally to measure surface changes. Results: The study showed statistically significant results (p<0.05) when measurements of changes in surface roughness of samples treated with glycine powder air-polishing were compared with ultrasonic scaling and chlorhexidine acetate powder air-polishing were compared with ultrasonic scaling. Surface texture loss as well as time taken for stain removal was minimum with glycine powder and maximum with ultrasonic scaling. Conclusion: Air-polishing with glycine powder was least abrasive on root surface followed by chlorhexidine acetate powder air-polishing. This is because of the lower particle size of glycine which also covers larger area in lesser time.  


2019 ◽  
Vol 3 (9) ◽  
pp. 283-289
Author(s):  
Shuchi Sukul ◽  
Goldy Rathee ◽  
Parimal Anand ◽  
Sakshi Kataria ◽  
Pratibha Taneja

OBJECTIVES: The present research was conducted to assess incidences of root microcracks caused by hand and rotary file system at different lengths MATERIAL AND METHODS: This in-vitro study was undertaken to assess incidence of root microcracks caused by hand and rotary file system at different lengths In total, 100 the mandibular premolar with straight roots determined with intact, fully formed apices were taken. Samples were randomly distributed into 5 groups based on the file system used: a) Group A: Control, b) Group B: Reciproc, c) Group C: WaveOne, d) Group D: One Shape and e) Group E: ProTaper. Pearson Chi-square test was used to determine the differences between groups. The dentinal defects were expressed as percentage of samples with microcracks in each group. Level of statistical significance was set at p-value less than 0.05. RESULTS: The chi square test was used to compare the Distribution of the number of teeth in which cracks were observed on the horizontal sections. It was found to be significant with group ProTaper showing maximum cracks at 3,6,9 mm level as compared to other file systemCONCLUSION: Nickel-titanium instruments causes cracks on the apical root surface or in the root canal wall. ProTaper causes maximum dentinal cracks as compared to other file systems


Sign in / Sign up

Export Citation Format

Share Document