scholarly journals Motion Analysis Focusing on Rotational Movements of Professional Female Baseball Pitchers: Comparison with Male University Baseball Pitchers

Author(s):  
Yoshikazu Azuma ◽  
Tomoyuki Matsui ◽  
Machiko Hiramoto ◽  
Ruo Hashimoto ◽  
Kanta Matsuzawa ◽  
...  

Purpose: The purpose of this study was to compare pitching motion of the professional female baseball pitchers with the male university baseball pitchers focused on the pelvic and thoracic movements. Subjects and methods: The participants were 15 healthy professional female baseball pitchers (11 right-handers and 4 left-handers; age, 21.7 ± 3.2 years; height, 162.5 ± 5.1 cm; weight, 59.0 ± 6.6 kg) and 14 healthy male university baseball pitchers (12 right-handers and 2 left-handers; age, 19.9 ± 0.8 years; height, 176.4 ± 3.0 cm; body mass, 73.1 ± 3.0 kg). Throwing motion was captured by three-dimensional motion analysis system. Kinematic data of the lead hip, pelvis, thorax, and dominant shoulder were collected and the joint angle at maximum external rotation phase and ball release phase were compared. Results: The female baseball pitchers rotated pelvis and thorax more than the male at the maximum external rotation phase and ball release phase (p < 0.05). At the same, the pelvis and thorax of the female baseball pitchers were tilted significantly closer to horizontal plane than the male (p < 0.05). The pelvis and thorax of the male baseball pitchers was tilted to non-dominant lateral side. Conclusions: The results of this study indicate that the pelvic and thoracic movements of the professional female baseball pitchers was different from male university pitchers.

Author(s):  
Hwai-Ting Lin ◽  
Yu-Chuan Lin ◽  
You-Li Chou ◽  
Hung-Chien Wu ◽  
Rong-Tyai Wang ◽  
...  

Previous studies have reported that pitchers with glenohumeral internal rotation deficit (GIRD) may increase the risk of shoulder injury. However, limited information is available regarding the specific effects of GIRD in baseball pitching. The purpose of this study was to investigate whether baseball pitchers with GIRD change their pitching mechanism. Fifteen baseball pitchers with GIRD and 15 pitchers without GIRD were recruited from university or senior high-school teams. A three-dimensional motion analysis system (Eagle System, Motion Analysis Corporation, Santa Rosa, CA, USA) was used to capture the pitching motion while performing fastball pitches. The kinematics and kinetics of the throwing shoulder and trunk were analyzed based on motion captured data. The Mann–Whitney U test was used to test the differences of the analyzed parameters between two groups. At the instant of ball release, the GIRD group showed lower shoulder external rotation and trunk rotation, and larger shoulder horizontal adduction. In addition, the GIRD group exhibited a significantly larger shoulder inferior force in the cocking and acceleration phase, and a significantly larger internal rotation torque in the acceleration phase. The present results suggested that pitchers with GIRD need stretch training to enlarge joint range of motion, and to improve trunk strength and flexibility to alleviate potential problems associated with pitching in GIRD pitchers.


2020 ◽  
Vol 33 (5) ◽  
pp. 761-767
Author(s):  
Yongwook Kim ◽  
Seungmook Kang

BACKGROUND: Few studies have explored the relationship between muscle strength, range of motion (ROM), and balance in the horizontal plane of the hip joint using three-dimensional (3D) motion analysis. OBJECTIVE: We investigate the relationships of hip internal rotation (IR) and external rotation (ER) ROM, measured using a 3D motion capture system, with hip internal and external rotator strength and single-leg standing balance. METHODS: The participants were 40 healthy adults. Kinematic data on hip ROM were collected using an eight-camera motion analysis system. Hip rotational strength measurements were obtained using hand-held isometric dynamometry. A Single-leg standing test and a pendular test were conducted to evaluate static and dynamic balance ability using BioRescue. RESULTS: Significant correlations were found between hip strength and each variable measured during hip ROM assessments (p< 0.05). Significant positive correlations were found between the hip IR/ER strength ratio and the IR/ER ROM ratio (r= 0.72, p< 0.01). The subgroup with a normal IR/ER ratio of hip rotator strength and ROM showed significantly better dynamic balance ability than the subgroup with a hip rotator muscle imbalance (p< 0.05). CONCLUSIONS: There is a significant relationship between hip IR/ER strength and IR/ER ROM with a normal hip IR/ER strength and ROM ratio positively affecting dynamic balance ability.


2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Phob Ganokroj ◽  
Jirayu Chaowalitwong ◽  
Pichitpol Kerdsomnuek ◽  
Narumol Sudjai ◽  
Pisit Lertwanich ◽  
...  

Abstract Background Sitting involves many activities of daily life and requires most motion in the hip joint. Asians have more hip flexion and external rotation motions than Westerners owing to cultural and lifestyle differences. Being aware of the normal range of hip motion is essential in clinical practice. Limited research has focused on the hip motions of common sitting positions. The objective was to determine the hip motions of 10 common sitting positions, and to determine whether gender or being overweight affects the range of hip motions. Methods An experimental cross-sectional study was conducted to determine hip motions by using a standard, three-dimensional, motion-analysis system. Healthy subjects performed 10 sitting positions during 3 trials. All hip-kinematic data were measured on the dominant leg of each participant, except for the right- and left-monk positions (both hips were analyzed). Density plots were constructed and statistical analyses were performed to detect the differences between groups (male and female; non-overweight and overweight). Results The 48 participants comprised 24 males and 24 females. Most were right-leg dominant (45 participants, 93.8%). Of the 22 participants in the overweight group (body mass index ≥23 kg/m2), 18 (75%) were male. Squatting showed the highest flexion angle (99.7°, 47.3°–122°). Cross-legged sitting had the highest abduction angle (28.9°, 9.9°–45.7°) and the largest external rotation angle (62°, 37.6°–81.7°). In the female group, there were trends toward a greater flexion angle (4 out of 10 sitting positions) and a smaller abduction angle (6 out of 9 positions), with P values < 0.05. As to body weight, the overweight participants had a smaller flexion angle but a greater abduction angle, with 5 out of 9 positions having a P value < 0.05. Kinematic data of the transverse plane revealed that the heterogeneity of the rotational angles depended on the sitting position. Conclusions This study provided the functional hip motions of common Asian sitting positions. The kinematic data can be utilized in clinical practice as reference values to determine safe positions. Gender and being overweight affected the hip angles in the sagittal and frontal planes. Trial registration Number TCTR20181021004, retrospectively registered at the Thai Clinical Trials Registry (http//:www.clinicaltrials.in.th).


2021 ◽  
Author(s):  
Phob Ganokroj ◽  
Jirayu Chaowalitwong ◽  
Pichitpol Kerdsomneuk ◽  
Narumol Sudjai ◽  
Pisit Lertwanich ◽  
...  

Abstract Background Sitting involves many activities of daily life and requires most motion in the hip joint. Asians have more hip flexion and external rotation motions than Westerners owing to cultural and lifestyle differences. Being aware of the normal range of hip motion is essential in clinical practice. Limited research has focused on the hip motions of common sitting positions. The objective was to determine the hip motions of 10 common sitting positions, and to determine whether gender or being overweight affects the range of hip motions.Methods An experimental cross-sectional study was conducted to determine hip motions by using a standard, three-dimensional, motion-analysis system. Healthy subjects performed 10 sitting positions during 3 trials. All hip-kinematic data were measured on the dominant leg of each participant, except for the right- and left-monk positions (both hips were analyzed). Density plots were constructed and statistical analyses were performed to detect the differences between groups (male and female; non-overweight and overweight).Results The 48 participants comprised 24 males and 24 females. Most were right-leg dominant (45 participants; 93.8%). Of the 22 participants in the overweight group (body mass index ≥ 23 kg/m2), 18 (75%) were male. Squatting showed the highest flexion angle (99.7º; 47.3º–122º). Cross-legged sitting had the highest abduction angle (28.9º; 9.9º–45.7º) and the largest external rotation angle (62º; 37.6º–81.7º). In the female group, there were trends toward a greater flexion angle (4 out of 10 sitting positions) and a smaller abduction angle (6 out of 9 positions), with P values < 0.05. As to body weight, the overweight participants had a smaller flexion angle but a greater abduction angle, with 5 out of 9 positions having a P value < 0.05. Kinematic data of the transverse plane revealed that the heterogeneity of the rotational angles depended on the sitting position.Conclusions This study provided the functional hip motions of common Asian sitting positions. The kinematic data can be utilized in clinical practice as reference values to determine safe positions. Gender and being overweight affected the hip angles in the sagittal and frontal planes.Trial registration: Number TCTR20181021004, retrospectively registered at the Thai Clinical Trials Registry (http://www. clinicaltrials.in.th).


Animals ◽  
2021 ◽  
Vol 11 (5) ◽  
pp. 1242
Author(s):  
Georg Haider ◽  
Ursula Schulz ◽  
Nikola Katic ◽  
Christian Peham ◽  
Gilles Dupré

Single-port access systems (SPASs) are currently used in human and veterinary surgeries. However, they pose technical challenges, such as instrument crowding, intra- and extracorporeal instrument collision, and reduced maneuverability. Studies comparing the maneuverability of the scopes and instruments in different SPASs are lacking. This study aimed to compare the maneuverability of three different SPASs: the Covidien SILS-port, Storz Endocone, and glove port. A clear acrylic box with artificial skin placed at the bottom was used to mimic the abdominal wall and cavity. The three SPASs were placed from below, and a 10-mm endoscope and 5-mm instrument were introduced. A motion analysis system consisting of 18 cameras and motion analysis software were used to track the movement of the endoscope and instrument, to determine the volume of the cone-shaped, three-dimensional figures over which movement was possible, with higher values indicating greater maneuverability. The Mann–Whitney U test was used for the analysis. The maneuverability of the endoscope alone was significantly higher in the glove port system than in the other two SPASs. When inserting an additional instrument, the maneuverability significantly decreased in the SILS-port and Endocone, but not in the glove port. The highest maneuverability overall was found in the glove port.


2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Phob Ganokroj ◽  
Nuchanun Sompornpanich ◽  
Pichitpol Kerdsomnuek ◽  
Bavornrat Vanadurongwan ◽  
Pisit Lertwanich

Abstract Background Measurement of hip rotation is a crucial clinical parameter for the identification of hip problems and the monitoring of symptoms. The objective of this study was to determine whether the use of two smartphone applications is valid and reliable for the measurement of hip rotation. Methods An experimental, cross-sectional study was undertaken to assess passive hip internal and external rotation in three positions by two examiners. The hip rotational angles were measured by a smartphone clinometer application in the sitting and prone positions, and by a smartphone compass application in the supine position; their results were compared with those of the standard, three-dimensional, motion analysis system. The validities and inter-rater and intra-rater reliabilities of the smartphone applications were evaluated. Results The study involved 24 participants. The validities were good to excellent for the internal rotation angles in all positions (ICC 0.81–0.94), good for the external rotation angles in the prone position (ICC 0.79), and fair for the sitting and supine positions (ICC 0.70–0.73). The measurement of the hip internal rotation in the supine position had the highest ICC value of 0.94 (0.91, 0.96). The two smartphone applications showed good-to-excellent intra-rater reliability, but good-to-excellent inter-rater reliability for only three of the six positions (two other positions had fair reliability, while one position demonstrated poor reliability). Conclusions The two smartphone applications have good-to-excellent validity and intra-rater reliability, but only fair-to-good inter-rater reliability for the measurement of the hip rotational angle. The most valid hip rotational position in this study was the supine IR angle measurement, while the lowest validity was the ER angle measurement in the sitting position. The smartphone application is one of the practical measurements in hip rotational angles. Trial registration Number 20181022003 at the Thai Clinical Trials Registry (http://www.clinicaltrials.in.th) which was retrospectively registered at 2018-10-18 15:30:29.


Author(s):  
S. F. Almashqbeh

The kinematic and kinetic differences between two styles of stair climbing, namely regular stair climbing (RSC) and lateral stair climbing (LSC), was studied. A four-step wooden stair instrumented with two force plates was used as the action platform. The kinematic and kinetic recordings were collected using a 6-camera, 2-force plate commercial three-dimensional motion analysis system. The LSC activity was subdivided into LSCL activity, where the right leg was the leading leg, and LSCT.


Sign in / Sign up

Export Citation Format

Share Document