scholarly journals Rheological Properties and Its Effect on the Lubrication Mechanism of PVP K30 and PVP 40-50 G as Artificial Synovial Fluids

Inventions ◽  
2021 ◽  
Vol 6 (4) ◽  
pp. 61
Author(s):  
Ankit Kotia ◽  
Sunil More ◽  
Aman Yadav ◽  
Thota Venkata Sai Yaswanth Mohan ◽  
Arnepaplli Harshavardhan Naidu ◽  
...  

The effect of polyvinylpyrrolidone (PVP) on the rheological properties of joint prostheses is still unclear, despite its good lubricity and biocompatibility. In the present work, PVP K30 and PVP 40-50 G solutions at different concentrations were analyzed for rheological and lubrication properties. The rheological properties of the samples were measured at a shear rate range of 0–1800 s−1 (advanced air bearing rheometer Bohlin Gemini 2 and Plate MCR 72/92 rheometer for PVP30 and PVP 40-50 G, respectively). It was found that both the viscosity and shear stress of the samples reduced with a shear rate increase. PVP 40-50 G/sterile water showed higher viscosity as compared to the PVP K30/sterile water sample at a lower shear rate. However, at a higher shear rate, the PVP K30 sample produced better results. Further numerical study results showed the pressure and molecular viscosity distributions. The inclusion of PVP improved the load caring capacity and hence, it is a promising lubrication additive for artificial joints.

2013 ◽  
Vol 1547 ◽  
pp. 123-128 ◽  
Author(s):  
Nobuko Fukuda ◽  
Shintaro Ogura ◽  
Ken-ichi Nomura ◽  
Hirobumi Ushijima

ABSTRACTWe synthesized viscous precursors to indium gallium zinc oxide (IGZO) using three kinds of alcoholamines, ethanolamine (EA), diethanolamine (DEA), and triethanolamine (TEA), by a simple process. The viscous precursors are obtained just by vigorous stirring of alcoholamine and urea in an aqueous solution containing the metal nitrates during heating at 150-160 °C. The precursor containing EA (EA-precursor) is a pale-orange suspension containing aggregates of the metal hydroxides and shows pseudoplastic flow. The precursors containing DEA (DEA-precursor) and TEA (TEA-precursor) are transparent pale-yellow and dark-orange sols, respectively. They give Newtonian flow in the lower shear rate and pseudoplastic flow in the higher shear rate. Higher concentration of metal salts leads to higher viscosity of the precursors. According to thermogravimetry-differential thermal analysis (TG-DTA) for the EA- and DEA-precursors, evaporation of alcoholamine occurs at around each boiling point and subsequently formation of metal oxides occur at around 300 °C. In the case of the TEA-precursor, formation of metal oxides occurs before pyrolysis of TEA attributed to the higher boiling point of TEA. The thin IGZO film, which is prepared by spin-coating of the diluted DEA-precursor and subsequent sintering at 450 °C for 30 min, shows 0.02 cm2 ·V-1s-1 of the mobility and 10-5 of the on/off ratio. The highly viscous DEA-precursor containing high concentration of metal ions allows patterning in an area of 100 cm2 onto a surface of a silicon wafer with screen printing.


2016 ◽  
Vol 1133 ◽  
pp. 236-240
Author(s):  
Teku Zakwan Zaeimoedin ◽  
Mazlina Mustafa Kamal ◽  
Ahmad Kifli Che Aziz

In tyre industries, rheological and processability properties of rubber and polymer are great of importance since there are alot extrusion processes involved in the tyre manufacturing other than calendaring and moulding processes. Uniformity and consistency in the flow behaviour and processability of rubber are essential in providing the solution to the rubber industries in order to improve productivity, products quality and energy conservation. In this works, effects of silane coupling agent on rheological behaviour and extrusion performance of silica filled ENR tread compounds were studied and compared to NR/BR tread compound. The compounds were prepared by melt mixing in tangential internal mixer, while the rheological properties of compounds were determined by Capillary Rheometer, Cure Rheometer and Mooney viscometer. The compound were further examined for its extrudability performance evaluation by extruded the rubber through 30mm cold feed extruder machine using ASTM Extrusion Die, ‘Garvey’ type. Results showed that, ENR/silica compounds exhibit higher shear viscosity curves as compared to NR/BR compound at low shear rate regime. However an opposite trend was observed towards high shear rate regime tested which ENR/silica compounds gave slightly lower shear viscosity curve compared to NR/BR compound. As for extrudability performance evaluation, NR/BR compound gave better extrusion characteristics and appearance as compared to ENR/silica compounds.


1986 ◽  
Vol 55 (02) ◽  
pp. 184-188 ◽  
Author(s):  
I A Feuerstein ◽  
J Kush

SummaryThe adhesion and detachment of platelets on surface-bound albumin and surface-bound fibrinogen were studied. Fluorescent video-microscopy of platelets labelled with mepacrine was used to provide continuous information. Glass tubes (I.D. 1.3 mm) were precoated with either human albumin or human fibrinogen before exposure to a suspension of washed platelets and red cells. Observations were made 0.5 cm from the tube’s entrance over a 1370 μm2 portion of lumen. The rate at which cells leave the measurement area and the percent of initially attaching cells which leave are independent of protein coating but increase with flow rate. The percent of initially attaching platelets which permanently adhere is equal for both protein coatings but the pathways leading to this result can be different. For the lower shear rate studied, 80 s−1, the percent of cells which permanently adhere on first contact is less for albumin than for fibrinogen; the percent of initially attaching cells which adhere and then move before permanent adhesion is greater for albumin. The mechanism of detachment and reattachment leads to the equality of the overall adhesion efficiencies for the two protein coatings at 80 s−1. For the higher shear rate studied, 456 s−1 the adhesion pathways for both coatings were the same.


2021 ◽  
Vol 925 ◽  
Author(s):  
Lu Jing ◽  
Julio M. Ottino ◽  
Richard M. Lueptow ◽  
Paul B. Umbanhowar

Particle segregation is common in natural and industrial processes involving flowing granular materials. Complex, and seemingly contradictory, segregation phenomena have been observed for different boundary conditions and forcing. Using discrete element method simulations, we show that segregation of a single particle intruder can be described in a unified manner across different flow configurations. A scaling relation for the net segregation force is obtained by measuring forces on an intruder particle in controlled-velocity flows where gravity and flow kinematics are varied independently. The scaling law consists of two additive terms: a buoyancy-like gravity-induced pressure gradient term and a shear rate gradient term, both of which depend on the particle size ratio. The shear rate gradient term reflects a kinematics-driven mechanism whereby larger (smaller) intruders are pushed toward higher (lower) shear rate regions. The scaling is validated, without refitting, in wall-driven flows, inclined wall-driven flows, vertical silo flows, and free-surface flows down inclines. Comparing the segregation force with the intruder weight results in predictions of the segregation direction that match experimental and computational results for various flow configurations.


2019 ◽  
Vol 39 (2) ◽  
pp. 143-151
Author(s):  
Wattana Teppinta ◽  
Banja Junhasavasdikul ◽  
Nattapong Nithi-Uthai

Abstract A unique technology for producing thermoplastic vulcanizate (TPV) has been developed using an intermeshing-type internal mixer (ITM). TPV produced by the ITM was compared with that produced using a co-rotating twin screw extruder (Co-TSE) to assess the former’s commercial possibilities. TPV, originating from ethylene-propylene-diene monomer (EPDM) and polypropylene (PP), was produced by both machines with equal filled volumes, same shear rate, and same specific mechanical energy. Results indicate that ITMs can be used to produce TPV with mechanical properties comparable to those of TPV produced by Co-TSE. TPV can be produced with a lower shear rate with ITM compared to Co-TSE. A long residence time can be maintained in the mixing chamber of the ITM, allowing high conversion of the cross-linking reaction and resulting in better elastic recovery properties due to the higher cross-linking density. However, this resulted in higher viscosity of TPV produced by ITM.


2011 ◽  
Vol 183-185 ◽  
pp. 1726-1730 ◽  
Author(s):  
Qian Wang ◽  
Cheng Shen Zhu ◽  
Ping Du ◽  
Su Qin He

The rheological behaviors of nylon610 and nylon610/montmorillonite nanocomposites had been studied by means of HAAKE-Ⅱrheometer. The results showed that nylon610 and nylon610/montmorillonite composites were pseudoplastic fluid. The non-Newtonian indexes, which were in the range of 0.49~0.82 at differern temperatures, decreased with the addition of montmorillonite. What is more, the apparent viscous activation energy decreased, which showed the effect of temperature on apparent viscosity of the nanocomposites was weaker than that of pure nylon610, apparent viscosity increased with the increase of montmorillonite, especially at the lower shear rate.


2011 ◽  
Vol 490 ◽  
pp. 25-32 ◽  
Author(s):  
Józef Salwiński ◽  
Wojciech Horak

Preliminary analysis of magnetorheological fluid usability in fluid lubricated bearings has been described in the present study. Results of the study aimed at rheological properties of chosen fluids, which possess magnetic properties (both ferrofluids and magnetorheological fluids) with respect to their application in slide bearings have been presented Preliminary analysis of potential advantages related with the magnetic fluid bearing construction was carried out. Results of measurements of normal force developed within magnetorheological fluid and ferrofluid in result of magnetic field action at various shear rate values have been presented.


Blood ◽  
2013 ◽  
Vol 122 (21) ◽  
pp. 1144-1144
Author(s):  
Grazia Loredana Mendolicchio ◽  
Patrizia Marchese ◽  
Corrado Lodigiani ◽  
Anna Colombo ◽  
Matteo Ferrari ◽  
...  

Abstract Background Warfarin, an oral anti-vitamin K anticoagulant, effectively prevents venous thrombosis in patients at risk, but requires constant laboratory monitoring to maintain a therapeutic range and reduce bleeding complications. For many indications, oral inhibitors of coagulation factor (F) Xa and thrombin (FIIa) have proven at least as effective as warfarin with comparable risk of bleeding complications, but with the advantage of administration in a fixed dose without laboratory monitoring. Although rare, thrombosis may still occur in treated patients and bleeding remains a potentially serious complication. Aims The assumption that an equal dose of an anticoagulant drug can achieve a comparable antithrombotic effect in different patients implies that an appropriate test of efficacy should yield results within a relatively narrow range of values. Thus, we measured the volume of platelet aggregates and fibrin deposited onto thrombogenic surfaces exposed to flowing blood to compare the antithrombotic effect of rivaroxaban (Riv), a FXa inhibitor, and dabigatran (Dab), a thrombin inhibitor, with that of warfarin (Warf) in patients undergoing total knee or hip replacement and treated to prevent deep vein thrombosis. Methods Blood containing 0.011 M trisodium citrate was recalcified with 5 mM CaCl2 and perfused at the wall shear rate of 300 and 1500 s-1 over a surface coated with fibrillar collagen type I, or at 300 s-1 over recombinant tissue factor (TF). Platelet aggregates and fibrin were detected in situ through distinct fluorochromes and the respective volumes were measured from stacks of confocal optical sections. We tested 12 normal controls, 12 patients treated with Warf (INR between 1.94 and 2.90), 10 patients treated with Riv and 10 with Dab between 8 and 16 days from the initiation of therapy. Statistical analysis was performed using one-way analysis of variance. Results On the collagen surface at the lower shear rate of 300 s-1, the blood of Warf patients yielded an average volume of deposited fibrin significantly lower not only of control (P<0.001) but also Riv and Dab patients (P<0.01); the latter two were not different from control. All 12 Warf samples, but only 5/10 Riv and 4/10 Dab, were below the lower limit of normal values. In contrast, at the higher shear rate of 1500 s-1 the average fibrin volume was significantly lower than control in Warf (P<0.001) as well as Riv and Dab (P<0.01) blood. Notably, at both lower and higher shear rate the average volume of platelet aggregates was not decreased in Warf, Riv or Dab blood; rather, the tendency was to increased. On the TF surface, stable thrombus formation in flowing blood could only be assessed at the lower shear rate of 300 s-1, since even the reactivity of normal samples was negligible at 1500 s-1; thus we focused on blood from Riv and Dab treated patients who showed only an insignificant reduction of fibrin formation at 300 s-1 on the collagen surface. In contrast, thrombus volume in the blood of Riv and Dab treated patients was decreased on the TF surface under the same flow conditions. In the case of Dab, the average volume of both platelet aggregates and fibrin was significantly lower (P<0.01) than in control blood; with Riv, fibrin volume was also significantly reduced (p<0.01), but that of platelet aggregates was not. Of note, the volume of fibrin formed in Dab samples was only one third of that in Riv samples. Summary/Conclusions The significance of findings obtained with a test of thrombus formation in ex vivo flowing blood and the potential value for interpreting the evidence provided by clinical trials remain to be established prospectively. This notwithstanding, it is apparent that different agents have different anticoagulant effects, and those administered in a “one fits all” dose and without laboratory monitoring lead to a greater inter-individual variability of results. The influence of the thrombogenic surface on the ex vivo anticoagulant potency of drugs with distinct coagulation targets suggests that treating or preventing different thrombotic disorders may require a selective choice among therapeutic agents targeting specific coagulation pathways and physiologic inhibitors. Disclosures: No relevant conflicts of interest to declare.


Author(s):  
Hafiz Ahmad ◽  
M'hamed Boutaous ◽  
Shihe Xin ◽  
Hervé Pabiou ◽  
Dennis A. Siginer

Abstract In this paper, the rheological characteristics of aqueous PEO (Polyethylene oxide) solution with very high molecular weight 4 × 106 g/mol is investigated. Shear flow measurements were carried out in steady and transient modes. The unique behavior of PEO is found to be heavily dependent on the input shear rate and the mechanism of data generation. Generally, PEO is found to be shear-thinning throughout the experiments, but at the start of the experiments at low shear rates, minimum input shear value also affects the shear-thinning behavior. In this study, we investigate the critical method of applying input shear to the samples in the lower shear rate regime. Surprisingly, different input methods yield different results. Viscosity curves obtained through shear flow experiments are found to be significantly dependent on the input method of shear rate. Experimental measurements were validated by Cross and Carreau-Yasuda models.


Sign in / Sign up

Export Citation Format

Share Document