scholarly journals Swept Source Optical Coherence Tomography Analysis of a Selected Eye’s Anterior Segment Parameters in Patients with Pseudoexfoliation Syndrome

2022 ◽  
Vol 11 (1) ◽  
pp. 268
Author(s):  
Michał Dembski ◽  
Anna Nowińska ◽  
Klaudia Ulfik-Dembska ◽  
Edward Wylęgała

Background: Pseudoexfoliation syndrome (PEX) is a systemic, age-related disorder characterized by the production and accumulation of pseudoexfoliation material. To date, detailed characteristics have not been published regarding the iridocorneal angle and cornea in patients with pseudoexfoliation syndrome determined through swept source optical coherence tomography (SS-OCT). Methods: A total of 150 eyes of patients with pseudoexfoliation syndrome (ages 69–86 years) and 166 eyes in a control group (ages 54–79 years) were analyzed. Results: The central corneal thickness in the PEX group was 549.56 μm and was slightly (insignificantly) higher than that of the control group (540.56 µm). The anterior chamber of the eye was visibly shallower in patients with PEX syndrome than in those of the control group (2.49 mm vs. 3.07 mm; p < 0.001). The Fourier analysis parameters of the cornea showed multiple differences between the PEX and control groups. With respect to iris area, the parameters showed statistically significant differences between the PEX and control groups in all four quadrants of the eye. No statistical significance was found in the PEX group for the iridocorneal angle parameters, or corneal and lens parameters depending on gender and age. Conclusions: PEX syndrome is characterized by a significant impact on the anterior eye segment, including higher anterior and posterior keratometric values, lower anterior chamber depth, higher iris thickness, and narrower angle parameters. The characteristic anterior eye segment features of PEX syndrome can be detected using SS-OCT, which could potentially assist clinicians in properly managing the disease.

Diagnostics ◽  
2021 ◽  
Vol 11 (4) ◽  
pp. 658
Author(s):  
Federico Corvi ◽  
Federico Zicarelli ◽  
Matteo Airaldi ◽  
Salvatore Parrulli ◽  
Mariano Cozzi ◽  
...  

Background: To compare four different optical coherence tomography (OCT) devices for visualization of retinal and subretinal layers in highly myopic eyes. Methods: In this prospective, observational, cross-sectional study, consecutive patients with high myopia and control subjects were imaged by four OCT devices: Spectralis OCT2, PlexElite 2.0 100 kHz, PlexElite 2.0 200 kHz and the Canon Xephilio OCT-S1. The acquisition protocol for comparison consisted of single vertical and horizontal line scans centered on the fovea. Comparison between the devices in the extent of visible retina, presence of conjugate image or mirror artifacts, visibility of the sclerochoroidal interface and retrobulbar tissue. Results: 30 eyes with high myopia and 30 control subjects were analyzed. The visualized RPE length was significantly different between the OCT devices with Xephilio OCT-S1 imaging the largest extent (p < 0.0001). The proportion of eyes with conjugate image artifact was significantly higher with the Spectralis OCT (p < 0.0001), and lower with the PlexElite 200 kHz (p < 0.0001). No difference in visibility of the sclerochoroidal interface was noted among instruments. The retrobulbar tissue was visible in a higher proportion of eyes using swept-source PlexElite 100 kHz and 200 kHz (p < 0.007) compared to the other devices. Conclusions: In highly myopic eyes, the four OCT devices demonstrated significant differences in the extent of the retina imaged, in the prevalence of conjugate image artifact, and in the visualization of the retrobulbar tissue.


2014 ◽  
Vol 55 (6) ◽  
pp. 3999 ◽  
Author(s):  
Hellen C. S. Römkens ◽  
Henny J. M. Beckers ◽  
Marc Frusch ◽  
Tos T. J. M. Berendschot ◽  
John de Brabander ◽  
...  

2021 ◽  
Author(s):  
Mohammad Zarei ◽  
Tahereh Mahmudi ◽  
Hamid Riazi-Esfahani ◽  
Behnam Mousavi ◽  
Nazanin Ebrahimiadib ◽  
...  

Abstract Fuchs uveitis (FU) is a chronic and often unilateral ocular inflammation and characteristic iris atrophic changes, other than heterochromia, are common in FU and are key to the correct diagnosis in many cases. With the advent of anterior segment optical coherence tomography (AS-OCT), some investigators attempted to quantitatively study these atrophic changes; mostly by introducing various methods to measure iris thickness in AS-OCT images. We aimed to present an automated method in a observational case series to measure the smoothness index (SI) of iris surface in AS-OCT images. The ratio of the length of the straight line connecting the most peripheral and central points of the anterior iris border (in nasal and temporal sides) to the actual length of this border on AS-OCT images, was defined as SI. In a uveitis referral center twenty-two eyes of 11 patients with unilateral Fuchs uveitis (FU) (7 female) and 22 eyes of 11 healthy control subjects underwent AS-OCT imaging. Image J and a newly developed MATLAB algorithm were used for manual and automated SI measurements, respectively. Agreement between manual and automated measurements was evaluated with Bland-Altman analysis and interclass correlation coefficient. The inter-eye difference of SI was compared between FU group and control group. Automated mean overall SI was 0.868 ± 0.037 and 0.840 ± 0.039 in FU and healthy fellow eyes, respectively (estimated mean difference = -0.028, 95% CI [-0.038, -0.018], p<0.001). Bland- Altman plots showed good agreement between two methods in both healthy and FU eyes. Interclass correlation coefficient between the manual and automated measurements in the FU and healthy fellow eyes was 0.958 and 0.964, respectively. Inter-eye difference of overall SI was 0.029 ± 0.015 and 0.012 ± 0.008 in FU group and control group, respectively (p=0.01). We concluded that he automated algorithm can rapidly and conveniently measure SI with results comparable to manual method.


2019 ◽  
Author(s):  
Man Hu ◽  
Qian Zheng ◽  
Zhangliang Li ◽  
Pingjun Chang ◽  
Yun-e Zhao

Abstract Background To assess the changes of anterior chamber angle in patients with shallow anterior chamber and normal anterior chamber after phacoemulsification and intraocular lens implantation (IOL) using anterior segment swept-source optical coherence tomography (AS-SS-OCT). Methods This was a prospective case control study; 60 eyes of 60 patients who underwent cataract surgery. Based on anterior chamber depth (ACD) and gonioscopy findings, the eyes were classified into two groups, shallow anterior chamber group (30 eyes) and normal anterior chamber group (30 eyes). AS-SS-OCT was used to measure ACD and angle parameters angle opening distance (AOD), angle recess area (ARA), trabecular iris space area(TISA), and trabecular iris angle (TIA). Serial changes in each group were measured before and 3 months after phacoemulsification and IOL, and the differences between the two groups were compared. Results All angle parameters including ACD, AOD, ARA, TISA, and TIA in both groups at 3 months after cataract surgery were significantly different from the preoperative values (p<0.01). In addition, we found significant differences of all angle parameters between groups of shallow anterior chamber (SAC) and normal anterior chamber (NAC) (All P< 0.05). Besides, the TISA750 in superior quadrant and anterior chamber volume (ACV) were significantly smaller in the group of SAC than those in the group of NAC (P = 0.041 and 0.002, respectively). Conclusions The parameters of anterior chamber increased significantly in both two groups but not increase to the same extent 3 months after phacoemulsification. Iris thickening may also be one of the narrow angle factors,not just age-related lens thickening.


2020 ◽  
Vol 7 ◽  
Author(s):  
Jiamin Xie ◽  
Qiuying Chen ◽  
Jiayi Yu ◽  
Hao Zhou ◽  
Jiangnan He ◽  
...  

Purpose: To investigate the morphologic features and identify the risk factors of myopic choroidal neovascularization (CNV).Methods: Eighty-eight eyes of 69 consecutive patients with myopic CNV were included in this study. About 109 eyes of 78 pathologic myopia patients without myopic CNV were randomly selected as the control group. Morphologic features and parameters including scleral thickness (ST), choroidal thickness (CT), posterior staphyloma height and the presence of scleral perforating vessels were obtained and measured by swept-source optical coherence tomography (SS-OCT). Binary logistic regression analysis was performed to identify the risk factors for myopic CNV.Results: Patients with myopic CNV had relatively shorter axial length (P &lt; 0.001) and thicker sclera (P &lt; 0.001) compared to those without. After adjusting age, gender and axial length, thick sclera (OR = 1.333, P &lt; 0.001 per 10-μm increase) and thin choroid (OR = 0.509, P &lt; 0.001 per 10-μm increase) were associated with the presence of myopic CNV. Scleral perforating vessels were detected in the area of myopic CNV in 78.67% of the subjects.Conclusions: A relatively thicker sclera and a thinner choroid are the biological indicators for myopic CNV on SS-OCT. Scleral perforating vessels may also play a pivotal role in the formation of myopic CNV.


2019 ◽  
Vol 103 (11) ◽  
pp. 1584-1589 ◽  
Author(s):  
Jay C Wang ◽  
Inês Laíns ◽  
Patrick Oellers ◽  
Ivana K Kim ◽  
Joan W Miller ◽  
...  

PurposeTo investigate the choroidal thickness (CT) and choroidal vascular densities (CVD) of patients with macular telangiectasia type 2 (MacTel2) and their association with other multimodal imaging features, using swept-source optical coherence tomography (SS-OCT).MethodsProspective, cross-sectional study. Consecutive patients with MacTel2 along with controls without any macular disease were included. Fundus photography, confocal blue reflectance, near-infrared reflectance, autofluorescence, fluorescein angiography, spectral domain OCT and SS-OCT were performed. Images were independently analysed by two graders, and CVD was calculated from binarised en face SS-OCT images. CT was obtained from the SS-OCT platform via built-in automated segmentation. Multilevel mixed-effects models were used for statistical analysis.ResultsThirty-nine eyes of 20 patients with MacTel2 and 29 eyes of 15 control patients were included. Average CT and perifoveal temporal CT did not differ significantly between eyes with MacTel2 and control eyes (p≥0.350), when accounting for confounding factors. Overall and temporal CVD also did not significantly differ between the two groups (p≥0.490).ConclusionCT and CVD did not significantly differ between MacTel2 and control eyes in this study using SS-OCT. Even though MacTel2 may include abnormalities involving the choroid, these are likely minor in comparison to the predominant retinal changes.


2020 ◽  
Vol 10 (1) ◽  
Author(s):  
Poemen Pui-man Chan ◽  
Gilda Lai ◽  
Vivian Chiu ◽  
Anita Chong ◽  
Marco Yu ◽  
...  

Abstract This study compared the test–retest variabilities and measurement agreement of anterior chamber angle (ACA) dimensions measured by two anterior segment swept-source optical coherence tomography (SS-OCT)—the ANTERION (Heidelberg Engineering, Heidelberg, Germany) and CASIAII (Tomey, Nagoya, Japan). Thirty-eight subjects, 18 patients with primary angle closure and 20 healthy participants with open angles, were included. The mean age was 54.7 ± 15.8 years (range: 26–75 years). One eye of each subject was randomly selected for anterior segment imaging by ANTERION and CASIAII, using the same scan pattern (6 evenly spaced radial scans across the anterior segment for three times) in the same visit. The between- and within-instrument agreement and repeatability coefficients of angle open distance (AOD500), trabecular-iris space area (TISA500), lens vault (LV), scleral spur-scleral spur distance (SSD), anterior chamber depth (ACD), and pupil diameter (PD) were measured. The anterior and posterior boundaries of the cornea, iris, and lens were automatically segmented by the SS-OCT instruments; the scleral spur was manually located by a single masked observer. There were significant differences between ANTERION and CASIAII measurements; the SSD, PD, and ACD were smaller whereas AOD500 and TISA500 were greater in ANTERION compared with CASIAII (P < 0.001). Anterior segment measurements obtained from the two SS-OCT instruments showed strong associations (R2 ranged between 0.866 and 0.998) although the between-instrument agreement was poor; the spans of 95% limits of between-instrument agreement were ≥ 1.5-folds than the within-instrument agreement for either instrument. Whereas both SS-OCT instruments showed low test–retest measurement variabilities, the repeatability coefficients of AOD500, TISA500, ACD, and PD were slightly smaller for CASIAII than ANTERION (P ≤ 0.012).


2019 ◽  
Vol 40 (Supplement_1) ◽  
Author(s):  
J Chen ◽  
G Z Wang ◽  
Z Liu ◽  
Y H Zhang ◽  
J C Guo ◽  
...  

Abstract Objectives To detect the potential mechanism of early spontaneous reperfusion (ESR) in STEMI. Background Early spontaneous reperfusion occurs in around 20% of STEMI and is associated with favorable outcomes. Optical coherence tomography (OCT) is more accurate in detecting subtle morphological details of the culprit lesion. Methods In this prospective study, a total of 107 consecutive patients with STEMI were enrolled from July 2016 to May 2017. Of that total, 21 (19.6%) met the criteria of angiographic ESR (TIMI-3 flow in the initial angiogram). Among those without ESR (TIMI-0 flow in the initial angiogram), 21 patients were assigned into the control group according to propensity score matching with the ESR group. The OCT findings and one-year clinical outcomes were compared between the two groups. Results Although baseline characteristics were comparable, plaque features significantly differed between the ESR and control group (P<0.001), including plaque rupture (23.8% vs. 66.7%), plaque erosion (47.6% vs. 33.3%), calcified nodule (9.5% vs. 0%) and vasospasm (19.1% vs. 0%). Red thrombus (19.1% vs. 85.7%) was far less found whereas white thrombus (61.9% vs. 14.3%) was more common in the ESR group. In addition, despite of less stent placement (0.6±0.5 vs. 1.3±0.9, P<0.001), patients in the ESR group had a non-statistically lower rate of cardiac adverse events (4.8% vs. 14.3%, P=0.269) during one-year follow up. The OCT finding Variables ESR group (n=21) Control group (n=21) P value The OCT imaging <0.001   Plaque erosion 10 (47.6) 7 (33.3)   Plaque rupture 5 (23.8) 14 (66.7)   Calcified nodule 2 (9.5) 0 (0)   Vasospasm 4 (19.1) 0 (0) The Type of Thrombus <0.001   Red thrombus 4 (19.1) 18 (85.7)   White thrombus 13 (61.9) 3 (14.3)   No thrombus (vasospasm) 4 (19.1) 0 (0)   MLA (mm2) 2.7±2.2 2.3±2.4 0.534 Values are n (%), mean ± SD. ESR = early spontaneous reperfusion; MLA = Minimum lumen area; OCT = optical coherence tomography. ESR and control group Conclusions Relief of coronary occlusion induced by non-ruptured plaque and platelet-rich thrombi may be one of the main mechanism underlying early spontaneous reperfusion in STEMI. Acknowledgement/Funding No.81470491 from the National Natural Science Foundation of China and No.7192078 from Beijing Municipal Natural Science Foundation to Dr. Li.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Yun Ji Lee ◽  
Yeon Jeong Lee ◽  
Jae Yeon Lee ◽  
Suhwan Lee

AbstractThe aim of this study is to compare the scleral thickness of central serous chorioretinopathy (CSC) eyes with controls using anterior segment optical coherence tomography (AS OCT). This prospective case control study included 15 patients (15 eyes) with CSC and 15 age and gender matched healthy subjects. All subjects underwent spectral domain OCT with enhanced depth imaging and swept source AS OCT of temporal sclera. We investigated difference in scleral thickness between the two groups and relationship between choroidal and scleral thickness. Among the 15 eyes in the study group, 1 eye had acute CSC, 4 had recurrent CSC, 7 had inactive CSC, and 3 had chronic CSC. There was no significant difference in terms of age, gender, axial length and spherical equivalent between the two groups. The choroidal and scleral thickness of the study group were significantly greater than those of the control group (P < 0.001, P = 0.034). Choroidal thickness was positively correlated with scleral thickness (P = 0.031). A thick sclera along with a thick choroid were demonstrated in CSC eyes using AS OCT. Scleral characteristics might be involved in the pathogenesis of CSC by affecting outflow resistance of venous drainage in choroidal circulation.