scholarly journals Effects of Pumice-Based Porous Material on Hydration Characteristics and Persistent Shrinkage of Ultra-High Performance Concrete (UHPC)

Materials ◽  
2018 ◽  
Vol 12 (1) ◽  
pp. 11 ◽  
Author(s):  
Kaizhi Liu ◽  
Rui Yu ◽  
Zhonghe Shui ◽  
Xiaosheng Li ◽  
Xuan Ling ◽  
...  

In this paper, two kinds of pumice particles with different diameters and water absorption rates are employed to substitute the corresponding size of river sands by volume fraction, and their effects on the hydration characteristics and persistent shrinkage of Ultra-High Performance Concrete (UHPC) are investigated. The obtained experimental results show that adopting a low dosage of 0.6–1.25 mm saturated pumice as the internal curing agent in UHPC can effectively retract the persistent shrinkage deformation of concrete without a decrease of strength. Heat flow calorimetry results demonstrate that the additional water has a retarding effect and promotes the hydration process. X-ray Diffraction (XRD) and Differential Thermal Gravimetry (DTG) are utilized to quantify the Ca(OH)2 content in the hardened paste, which can confirm that the external moisture could accelerate the early cement hydration and secondary hydration of active mineral admixtures. The Ca/Si ratio of C–S–H calculated by the Energy Dispersive Spectrometer (EDS) reveals that the incorporation of wet pumice can transform the composition and structure of hydration products in its effective area.

Fibers ◽  
2019 ◽  
Vol 7 (7) ◽  
pp. 67 ◽  
Author(s):  
Manish Roy ◽  
Corey Hollmann ◽  
Kay Wille

This paper studied the influence of fiber volume fraction ( V f ), fiber orientation, and type of reinforcement bar (rebar) on the uniaxial tensile behavior of rebar-reinforced strain-hardening ultra-high performance concrete (UHPC). It was observed that the tensile strength increased with the increase in V f . When V f was kept constant at 1%, rebar-reinforced UHPC with fibers aligned with the load direction registered the highest strength and that with fibers oriented perpendicular to the load direction recorded the lowest strength. The strength of the composite with random fibers laid in between. Moreover, the strength, as well as the ductility, increased when the normal strength grade 60 rebars embedded in UHPC were replaced with high strength grade 100 rebars with all other conditions remaining unchanged. In addition, this paper discusses the potential of sudden failure of rebar-reinforced strain hardening UHPC and it is suggested that the composite attains a minimum strain of 1% at the peak stress to enable the members to have sufficient ductility.


2014 ◽  
Vol 629-630 ◽  
pp. 96-103 ◽  
Author(s):  
Juan Yang ◽  
Gai Fei Peng ◽  
Yu Xin Gao ◽  
Hui Zhang

Ultra-high performance concrete (UHPC) incorporating coarse aggregate was prepared with common raw materials. Fresh concrete had excellent good workability with slump of 265 mm and slump spread of 673 mm. Compressive strength of UHPC at 56 d reached 150 MPa. However, UHPC exhibited high brittleness in terms of spalling failure which occurred during compression loading.The ratio of splitting tensile strength to compressive strength of about 1/18 and the ratio of flexural strength to compressive strength of about 1/14 at 56 d were also associated with the brittleness of UHPC in this research. Mineral admixtures and fluidity of fresh concrete influenced compressive strength of UHPC significantly. Moreover, UHPC had excellent permeation-related durability but considerable shrinkage. Autogenous shrinkage of UHPC was less than half of free shrinkage, for which the reason is unknown and needs further research.


2008 ◽  
Vol 385-387 ◽  
pp. 781-784
Author(s):  
Su Tae Kang ◽  
Jung Jun Park ◽  
Sung Wook Kim ◽  
Kee Nam Hong

This paper estimated the influence of volume of steel fiber on the tensile softening behavior in Ultra High Performance Concrete. Tensile softening curves were obtained from Three-Point Bending Test(TPBT) with notched beam. Inverse analysis method by Uchida et al. was introduced to obtain the tensile softening behaviors from the results of TPBT. We could find out that the increase of volume fraction of steel fiber makes the tensile strength higher but all of the curves converged on an asymptote with crack width. We proposed the equation of softening curve expressed by combination of plastic area and exponential descending area considering the volume fraction of steel fiber and ω0, which is corresponding to the maximum crack width of plastic area. We also carried out the crack propagation analysis using finite element method with smeared crack model and confirmed that the proposed equation had a good agreement with the experimental results.


2015 ◽  
Vol 665 ◽  
pp. 21-24
Author(s):  
B.I. Bae ◽  
Hyun Ki Choi ◽  
Chang Sik Choi

In this study, ductility of members with ultra-high performance concrete was investigated using moment-curvature analysis for the verification of safety under large deformation of ultra-high performance concrete structural members. For the analysis of members with ultra-high performance concrete, mathematical stress-strain model was selected among the results conducted by other researchers on the compressive and tensile behavior of high strength concrete and fiber reinforced concrete. According to the investigation on ductility of members with ultra-high performance concrete, decrease of ductility was observed with increase of tensile strength of concrete under the same reinforcement ratio. Members with 2~3% of reinforcement ratio, which usually be used in the field engineering, show the decrease of ductility with increase of fiber volume fraction. As a results of parametric study, limitation of maximum reinforcement ratio ( or limitation of net tensile strain ) suggested by current design code is not safe when using ultra-high performance concrete.


Materials ◽  
2019 ◽  
Vol 12 (19) ◽  
pp. 3254 ◽  
Author(s):  
Li ◽  
Feng ◽  
Ke ◽  
Pan ◽  
Nie

In order to study the direct shear properties of ultra-high performance concrete (UHPC) structures, 15 Z-shaped monolithic placement specimens (MPSs) and 12 Z-shaped waterjet treated specimens (WJTSs) were tested to study the shear behavior and failure modes. The effects of steel fiber shape, steel fiber volume fraction and interface treatment on the direct shear properties of UHPC were investigated. The test results demonstrate that the MPSs were reinforced with steel fibers and underwent ductile failure. The ultimate load of the MPS is about 166.9% of the initial cracking load. However, the WJTSs failed in a typical brittle mode. Increasing the fiber volume fraction significantly improves the shear strength, which can reach 24.72 MPa. The steel fiber type has little effect on the shear strength and ductility, while increasing the length of steel fibers improves its ductility and slightly reduces the shear strength. The direct shear strength of the WJTSs made from 16 mm hooked-type steel fibers can reach 9.15 MPa, which is 2.47 times the direct shear strength of the specimens without fibers. Finally, an interaction formula for the shear and compressive strength was proposed on the basis of the experimental results, to predict the shear load-carrying capacity of the cast-in-place UHPC structures.


2013 ◽  
Vol 357-360 ◽  
pp. 588-591 ◽  
Author(s):  
Yan Zhou Peng ◽  
Jin Huang ◽  
Jin Ke

Reactive powder concrete (RPC) is an ultra-high performance concrete (UHPC). Cement and silica fume content of RPC are generally rather high compared to the conventional concrete. The aim of this paper is to decrease the cement content of RPC by using phosphorous slag powder. Firstly the effect of grinding time on the activity index of phosphorous slag was investigated. And then, the mix proportion design of this UHPC containing phosphorous slag powder and silica fume was done through orthogonal design. The results indicate that the utilization of phosphorous slag powder in RPC is feasible when the dosage of phosphorous slag powder is about 35% (by weight of the binder) and the water-binder ratio is less than 0.18. By substituting phosphorous slag powder for a part of cement and keeping the water-binder ratio at about 0.14, UHPC specimens whose content of mineral admixtures, including phosphorous slag powder and silica fume, was about 40%~50% (by weight of the binder) were obtained after they had been cured in 80 °C water for 72 hours. The compressive and flexural strength of those specimens was more than 150 MPa and 20 MPa respectively.


Sign in / Sign up

Export Citation Format

Share Document