scholarly journals Minimum Radiant Exposure and Irradiance for Triggering Adequate Polymerization of a Photo-Polymerized Resin Cement

Materials ◽  
2021 ◽  
Vol 14 (9) ◽  
pp. 2341
Author(s):  
Qi Li ◽  
Hong-Lei Lin ◽  
Ming Zheng ◽  
Mutlu Ozcan ◽  
Hao Yu

This study aimed to establish the minimum radiant exposure and irradiance to trigger an adequate polymerization of a photo-polymerized resin cement. In total, 220 disc-shaped specimens (diameter of 10 mm and thickness of 0.1 mm) were fabricated using a photo-polymerized resin cement (Variolink N-transparent, Ivoclar Vivadent). To investigate the minimum radiant exposure, the specimens were polymerized with radiant exposures of 1, 2, 3, 4, 5, 6, and 18 J/cm2 (n = 20). During polymerization, the irradiance was maintained at 200 mW/cm2. To investigate the minimum irradiance, the specimens were polymerized with irradiances of 50, 100, 150, and 200 mW/cm2 (n = 20). During polymerization, the radiant exposure was maintained at the previously determined minimum radiant exposure. The Vickers microhardness (HV) and degree of conversion (DC) of the carbon double bond of the specimens were measured to determine the degree of polymerization of the specimens. The results were analyzed using one-way analysis of variance (ANOVA) and Tukey’s test (p < 0.05). In the investigation of the minimum radiant exposure, the HV and DC of the specimens polymerized with a radiant exposure from 1 to 5 J/cm2 were significantly lower than those with 18 J/cm2 (all p < 0.05). However, no significant difference in HV and DC was found between the specimens polymerized with 6 J/cm2 and 18 J/cm2 (p > 0.05). In the investigation of the minimum irradiance, the specimens polymerized with an irradiance of 50 mW/cm2 had significantly lower HV and DC than the specimens polymerized with an irradiance of 200 mW/cm2 (p < 0.05). However, no significant difference in the HV and DC was found among the specimens cured with irradiances of 100, 150, and 200 mW/cm2 (p > 0.05). In conclusion, the minimum radiant exposure and irradiance to trigger an adequate polymerization of the light-cured resin cement were 6 J/cm2 and 100 mW/cm2, respectively.

2015 ◽  
Vol 16 (5) ◽  
pp. 347-352 ◽  
Author(s):  
Seok-Hwan Cho ◽  
Arnaldo Lopez ◽  
David W Berzins ◽  
Soni Prasad ◽  
Kwang Woo Ahn

ABSTRACT Aim This study evaluated the effects of ceramic veneer thicknesses on the polymerization of two different resin cements. Materials and methods A total of 80 ceramic veneer disks were fabricated by using a pressable ceramic material (e.max Press; Ivoclar Vivadent) from a Low Translucency (LT) ingot (A1 shade). These disks were divided into light-cured (LC; NX3 Nexus LC; Kerr) and dual-cured (DC; NX3 Nexus DC; Kerr) and each group was further divided into four subgroups, based on ceramic disk thickness (0.3, 0.6, 0.9, and 1.2 mm). The values of Vickers microhardness (MH) and degree of conversion (DOC) were obtained for each specimen after a 24-hour storage period. Association between ceramic thickness, resin cement type, and light intensity readings (mW/cm2) with respect to microhardness and degree of conversion was statistically evaluated by using analysis of variance (ANOVA). Results For the DOC values, there was no significant difference observed among the LC resin cement subgroups, except in the 1.2 mm subgroup; only the DOC value (14.0 ± 7.4%) of 1.2 mm DC resin cement had significantly difference from that value (28.9 ± 7.5%) of 1.2 mm LC resin cement (p < 0.05). For the MH values between LC and DC resin cement groups, there was statistically significant difference (p < 0.05); overall, the MH values of LC resin cement groups demonstrated higher values than DC resin cement groups. On the other hands, among the DC resin cement subgroups, the MH values of 1.2 mm DC subgroup was significantly lower than the 0.3 mm and 0.6 mm subgroups (p < 0.05). However, among the LC subgroups, there was no statistically significant difference among them (p > 0.05). Conclusion The degree of conversion and hardness of the resin cement was unaffected with veneering thicknesses between 0.3 and 0.9 mm. However, the DC resin cement group resulted in a significantly lower DOC and MH values for the 1.2 mm subgroup. Clinical Significance While clinically adequate polymerization of LC resin cement can be achieved with a maximum 1.2 mm of porcelain veneer restoration, the increase of curing time or light intensity is clinically needed for DC resin cements at the thickness of more than 0.9 mm. How to cite this article Cho S-H, Lopez A, Berzins DW, Prasad S, Ahn KW. Effect of Different Thicknesses of Pressable Ceramic Veneers on Polymerization of Lightcured and Dual-cured Resin Cements. J Contemp Dent Pract 2015;16(5):347-352.


2021 ◽  
Vol 32 (6) ◽  
pp. 83-92
Author(s):  
Celso Bernardo de Souza-Filho ◽  
Izabela C. M. Moris ◽  
Vivian Colucci ◽  
Adriana Cláudia Lapria Faria ◽  
Érica A. Gomes

Abstract This study evaluated the surface characteristics and bond strength of Y-TZP treated with Er:YAG laser at different focal distances. 120 Y-TZP blocks were divided into five groups (n=24), according to the surface treatment: no treatment (C-); sandblasting with silica-coated aluminum oxide particles (C+); and Er:YAG laser application at focal distances of 1mm (Er:YAG-1), 4mm (Er:YAG-4), and 7mm (Er:YAG-7). Surface characteristics were analyzed using Vickers microhardness, confocal laser microscope, scanning electron microscopy (SEM), and X-ray diffractometer (XRD). For the bond strength test, 100 Y-TZP blocks were subdivided into two subgroups (n=10), according to the resin cement used: with (MDP+) or without 10-methacryloyloxydecyl dihydrogen phosphate (MDP-). The Vickers microhardness and surface roughness were analyzed by one-way ANOVA and bond strength by two-way ANOVA and Tukey's test for both (α=0.05). Vickers microhardness differences were not observed between the groups (p>0.05); C+ showed higher surface roughness values. SEM images showed micromorphological differences between the groups. The XRD data detected tetragonal crystals for C- and, for the other groups, tetragonal and monoclinic peaks. For bond strength, no statistically difference significance were observed among the cements with or without MDP (p>0.05) but showed significant difference between the surface treatments (C+ > C- = Er:YAG1 > Er:YAG4 = Er:YAG7) (p<0.05). Suggested that the Er:YAG laser cannot replace conventional treatment with aluminum oxide particles and the presence of MDP in the resin cement had no influence on the bond strength.


2020 ◽  
Vol 17 ◽  
pp. 204-214
Author(s):  
Amira Elsherbeny ◽  
Rizk Mostafa Shalaby ◽  
Sayed Mohamed Ghorab

Totally 80 disk-shaped specimens of Filtek™ Bulk-Fill, 3M ESPE, and Filtek™ Z250 XT, 3M ESPE, were prepared by using split-Teflon mold (4mm×10mm). Specimen characterization XRD, Surface roughness, degree of conversion, Surface microhardness, and depth of cure of the specimens were evaluated after the specimens were stored in distilled water in darkness at 37°C for 24 h. Statistical analysis was done using t-test with a significance level at p<0.05. FiltekTM Z350 XT showed the highest mean value of Vickers microhardness either on top surface 94.94% or bottom surface 69.92% and recorded 76.51% while FiltekTM Bulk-Fill was 66.85% for depth of cure. Filtek bulk-fill recorded a lower mean value of 0.73 for Surface roughness than FiltekTM Z350 XT and the highest degree of conversion of 84.34%. Statistical analysis showed that there was a significant difference between the mean values for all tested results. Increasing the filler content proved to have ability to enhance some properties, specially the surface roughness. Incorporation of some structurally rigid monomers like Bis-DMA, UDMA, TEGDMA within the resin matrix have a great influence on the measured properties, including degree of conversion reached to 84.34%, depth of cure to a level of 76.51% and Vickers microhardness to 94.94%.


2020 ◽  
Author(s):  
RQ Ramos ◽  
RR Moraes ◽  
GC Lopes

Clinical Relevance The use of multipeak LED light-curing guarantees efficiency on light activation of Ivocerin-containing light-cured resin cement.


2014 ◽  
Vol 4 (2) ◽  
pp. 55-64
Author(s):  
Amir Jayani ◽  
Zulman Efendi ◽  
Devi Silsia

This study aims to gain influence the thickness and concentration variations affect the characteristics of sago binder physical properties of catfish jerky. As well as getting influence the thickness and concentration variations affect the level of binder sago joy panelists in terms of organoleptic test. Data were analyzed by analysis of variance using the Analysis Of Variance (ANOVA). If there is a significant difference followed by a further test of DMRT 5% level (physical properties). While the hedonic test performed using Kruskal Wallis analysis. Results uniformity analysis (ANOVA) showed catfish fillet thickness and concentration of sago affect the physical properties of the water content and the level of violence. Where catfish jerky using sago binder 5% and 10% significantly different. The use of sago binder 5% and 10% led to an increase in water content. Besides the addition of the binder resulted in increasing levels of violence catfish jerky. Based on the statistics found that the influence of the thickness and concentration of the binder sago aroma, flavor and color of the sixth jerky catfish were not significantly different. But the texture was significantly different.


Author(s):  
Mohamed Abdel Rahman Maraghy

Objective: To show the consequence of two thicknesses of ceramic on the polymerization of resin cement light cured when three different lithium silicate ceramics were used. Materials and Methods: 42 ceramic slices were prepared from three types of ceramics, Emax CAD, Celtra Duo CAD and Vita suprinity CAD (n=14). They were further divided into two subgroups according to thicknesses into sub group thickness 0.5mm and sub group thickness 1mm (n=7). Teflon moulds were fabricated with specific dimensions, where the ceramic disc was placed followed by light cured resin cement Bisco choice 2 veneer and a glass slab with finger pressure applied. Curing with Ascent® PX LED light cure unit for 20 seconds took place, where the tip placed over the ceramic sample directly. Cement film was then separated from the ceramic disk and subjected to analysis by Fourier Transform Infrared Spectroscope. Uncured cement samples were also subjected to analysis. Results: Celtra DUO CAD ceramic showed higher degree of polymerization that of Emax and Vita suprinity while the difference between Emax and Suprinity on the degree of polymerization was not significant. Also, ceramic thicknesses had a significant effect on the degree of polymerization of the resin cement. Conclusion: Thickness of ceramics up to 1mm affects the polymerization of resin cement significantly.


Synthesis ◽  
2021 ◽  
Author(s):  
Dmitrii L. Obydennov ◽  
Vyacheslav D. Steben’kov ◽  
Konstantin L. Obydennov ◽  
Sergey A. Usachev ◽  
Vladimir S. Moshkin ◽  
...  

Abstract4-Pyrones bearing electron-donating and electron-withdrawing groups react with nonstabilized azomethine ylides to form pyrano[2,3-c]pyrrolidines in moderate to good yields. The reaction proceeds chemoselectively as a 1,3-dipolar cycloaddition of the azomethine ylide at the carbon–carbon double bond of the pyrone activated by the electron-withdrawing substituent. The reactivity of 4-pyrones toward azomethine ylides was rationalized by computational studies with the use of reactivity indexes. The pyrano[2,3-c]pyrrolidine moiety could be modified, for example by a ring-opening transformation under the action of hydrazine to provide pyrazolyl-substituted pyrrolidines.


2016 ◽  
Vol 95 (13) ◽  
pp. 1487-1493 ◽  
Author(s):  
N. Hirose ◽  
R. Kitagawa ◽  
H. Kitagawa ◽  
H. Maezono ◽  
A. Mine ◽  
...  

An experimental cavity disinfectant (ACC) that is intended to be used for various direct and indirect restorations was prepared by adding an antibacterial monomer 12-methacryloyloxydodecylpyridinum bromide (MDPB) at 5% into 80% ethanol. The antibacterial effectiveness of ACC and its influences on the bonding abilities of resin cements were investigated. To examine the antibacterial activity of unpolymerized MDPB, the minimum inhibitory and bactericidal concentrations (MIC and MBC) were determined for Streptococcus mutans, Lactobacillus casei, Actinomyces naeslundii, Parvimonas micra, Enterococcus faecalis, Fusobacterium nucleatum, and Porphyromonas gingivalis. Antibacterial activities of ACC and the commercial cavity disinfectant containing 2% chlorhexidine and ethanol (CPS) were evaluated by agar disk diffusion tests through 7 bacterial species and by MIC and MBC measurement for S. mutans. The effects of ACC and CPS to kill bacteria in dentinal tubules were compared with an S. mutans–infected dentin model. Shear bond strength tests were used to examine the influences of ACC on the dentin-bonding abilities of a self-adhesive resin cement and a dual-cure resin cement used with a primer. Unpolymerized MDPB showed strong antibacterial activity against 7 oral bacteria. ACC produced inhibition zones against all bacterial species similar to CPS. For ACC and CPS, the MIC value for S. mutans was identical, and the MBC was similar with only a 1-step dilution difference (1:2). Treatment of infected dentin with ACC resulted in significantly greater bactericidal effects than CPS ( P < 0.05, analysis of variance and Tukey’s honest significant difference test). ACC showed no negative influences on the bonding abilities to dentin for both resin cements, while CPS reduced the bond strength of the self-adhesive resin cement ( P < 0.05). This study clarified that the experimental cavity disinfectant containing 5% MDPB is more effective in vitro than the commercially available chlorhexidine solution to eradicate bacteria in dentin, without causing any adverse influences on the bonding abilities of resinous luting cements.


Sign in / Sign up

Export Citation Format

Share Document