scholarly journals Effect of Core Mass and Alloy on Cyclic Fatigue Resistance of Different Nickel-Titanium Endodontic Instruments in Matching Artificial Canals

Materials ◽  
2021 ◽  
Vol 14 (19) ◽  
pp. 5734
Author(s):  
Sebastian Bürklein ◽  
Lennart Zupanc ◽  
David Donnermeyer ◽  
Karsten Tegtmeyer ◽  
Edgar Schäfer

Instrument failure during root canal preparation is still a concern among endodontists. However, it remains unclear whether the use of more martensitic alloys or the cross-sectional design parameters (i.e., core mass) significantly improve fracture resistance. The aim of the study was to evaluate the impact of core mass and alloy on dynamic cyclic fatigue resistance of nickel-titanium endodontic instruments in matching artificial canals at body temperature. Two groups were tested. (A) taper 0.04: F360 (Komet, Lemgo, Germany), Twisted file (Sybron Endo, Glendora, CA, USA) (=TF), JIZAI (Mani, Tochigi, Japan) (=J_04) (all size #25) and the variable tapered TruNatomy (Dentsply, Ballaigues, Switzerland) (size #26) (=TN). (B) size #25; taper 0.06: (Mtwo (VDW, Munich, Germany), JIZAI (Mani) (=J_06), and variable tapered Hyflex EDM OneFile (Coltene Whaledent, Altstätten, Switzerland) (=HF). Time, number of cycles to fracture (NCF), and number and length of fractured fragments were recorded and statistically analysed using ANOVA Student-Newman-Keuls, Kruskal–Wallis or Chi-square test (significance level = 0.05). (A) TN showed the significantly shortest time until fracture, followed by TF, F360 and J_04 which also differed significantly, while NCF showed the following order: F360 < TN < TF < J_04 (p < 0.05). Only one J_04 but all instruments of the other groups fractured within the test-limit of 10 min. (B) Mtwo was significantly inferior concerning time until fracture and NCF, compared to J_06 and HF (p < 0.05), which did not differ significantly (p > 0.05). While all Mtwo instruments fractured, only four instruments failed in the other groups (p < 0.05). Within the limitations of this study, alloy and cross-sectional design (i.e., core mass) were critical factors regarding instrument failure, but none of these factors could be determined as a main parameter for increased or decreased time, and cycles to fracture. Rather, it seemed to be the interaction of multiple factors (e.g., longitudinal and cross-sectional design, alloy, and rotational speed) that was responsible for differences in the time and cycles to fracture. Nonetheless, all instruments had lifetimes that allow safe clinical use. However, the superiority or inferiority of an instrument with regard to cyclic fatigue based on laboratory results—even when identical trajectories are guaranteed—may be considered questionable, as the characteristics and design parameters of the instruments vary considerably, and the experimental setups lack additional clinical parameters and thus clinical relevance.

2021 ◽  
Vol 2021 ◽  
pp. 1-11
Author(s):  
Suhad Jabbar Hamed Al-Nasrawi ◽  
Zuha Ayad Jaber ◽  
Nibrass Talib Al-Quraine ◽  
Abtesam Imhemed Aljdaimi ◽  
Sattar Jabbar Abdul-Zahra Al-Hmedat ◽  
...  

Peracetic acid (PAA) is widely used as a sterilizing/disinfecting agent, and, in endodontics, it has been introduced as a promising irrigant in root canal treatment. It has been used at different concentrations to achieve various functions. However, endodontic instruments in contact with PAA of a certain concentration may affect their fatigue resistance. Therefore, the aim of this study was to investigate the impact of PAA on the cyclic fatigue resistance of three commercial heat-treated nickel-titanium (NiTi) rotary files. Three types of heat-treated NiTi rotary files were selected: One Curve (OC), ProTaper Gold (PTG), and Wave One Gold (WOG). Each type was divided into three subgroups (n = 6 for each file type): (1) untreated instruments; (2) files immersed in 0.002% PAA; and (3) files immersed in 0.35% PAA. The performance of each file type was tested in a simulated canal. The number of cycles to fracture (NCF) was determined to assess cyclic fatigue resistance of the files. Independent sample t-test was applied to compare each treated file within a subgroup with its respective control group, and one-way ANOVA was used for comparison among the main groups. All types of tested files revealed a significant decline in the cyclic fatigue resistance after exposure to 0.002% PAA except the PTG ( P = 0.209 ). After exposure of the files to a higher concentration (0.35% PAA), a dramatic reduction was demonstrated by all the groups. Before and after exposure of the files to PAA, PTG displayed the highest cyclic fatigue resistance, followed by the WOG, while the OC showed the lowest resistance. Exposure of heated-treated NiTi files to PAA in a relatively high or low concentration adversely affects the cyclic fatigue resistance. The PTG files demonstrated the best performance among the tested types and can be disinfected with 0.002% PAA for clinical purpose.


Metals ◽  
2020 ◽  
Vol 10 (2) ◽  
pp. 172 ◽  
Author(s):  
Saulius Drukteinis ◽  
Vytaute Peciuliene ◽  
Ruta Bendinskaite ◽  
Vilma Brukiene ◽  
Rasmute Maneliene ◽  
...  

The aim of this study was to investigate the shaping ability and cyclic fatigue resistance of Genius (GN) and WaveOne (WO) nickel-titanium (NiTi) instruments. Forty mesial root canals of mandibular molars were randomly divided into two groups, according to the instrument system used for root canal preparation (n = 20): GN and WO. Root canals were prepared to the full working length using the crown-down technique, with up to 40.04 instruments for GN group and 40.08 instruments for WO group. Specimens were scanned with a µCT before and after instrumentation. The changes in 3D parameters and degree of canal transportation were evaluated in the apical, middle and coronal thirds of root canals. Size 25, taper 0.04 (GN) and 0.08 (WO) instruments (n = 20) were used in simulated root canals until fracturing, and the number of cycles to failure (NCF) was recorded. The fractured files were investigated under a scanning electron microscope to characterize fractured surfaces. Data were analyzed using ANOVA post hoc Tuckey’s tests with the significance level set at 5%. The GN system was able to prepare the higher percentage of the canal surface with less canal transportation in all root canal thirds and displayed the higher resistance to cyclic fatigue in comparison to WO instruments (p < 0.05). However, the length of the fractured segments was not significantly different among the groups; meanwhile, SEM investigations revealed the typical topographic characteristics of fractured surfaces. Hybrid GN instruments demonstrated superior shaping ability and resistance to cyclic fatigue. However, both NiTi instrument systems prepared the root canals with no significant shaping errors, considerable changes in 3D parameters and no significant differences in the topographic appearances of the instrument surfaces after fractures.


2020 ◽  
Vol 2020 ◽  
pp. 1-6
Author(s):  
Reham Sharroufna ◽  
Mohammed Mashyakhy

Objective. The purpose of this study was to evaluate the effect of repeated autoclave sterilization on the cyclic fatigue resistance of heat-treated NiTi rotary endodontic instruments. Materials and Methods. Three NiTi rotary endodontic instruments (EdgeFile X7, EFX7 0.30/0.4; Vortex Blue, VB 0.30/0.4; and TRUShape, TS 0.30/0.6) were selected. Each group ( n = 24 each) was divided into 2 subgroups ( n = 12 each): sterilized instruments and nonsterilized instruments. The sterilized instruments were subjected to 10 cycles of autoclave sterilization. Twelve instruments from each different subgroups were tested for cyclic fatigue resistance, and the number of cycles to failure (NCF) was calculated. Means and standard deviations were calculated for each group, and data were statistically analyzed using the SPSS program ( P < 0.05 ). Results. Sterilized and nonsterilized EFX7 files showed the highest NCF compared with other file subgroups. Comparing the results between sterilized and nonsterilized instruments for each type of files, there was a statistically significant difference ( P < 0.05 ) only between sterilized and nonsterilized EFX7 files (1198 versus 755 NCF). The other instruments did not show significant differences ( P > 0.05 ) in the mean NCF as a result of sterilization cycles (VB, 606 versus 568 NCF; TS, 487 versus 442 NCF). Conclusion. Repeated cycles of autoclave sterilization increased the NCF of the new heat-treated files, with EFX7 showing statistically significant superior results compared with other files tested.


Materials ◽  
2020 ◽  
Vol 13 (22) ◽  
pp. 5246
Author(s):  
Sangmi Ahn ◽  
Jung-Hong Ha ◽  
Sang Won Kwak ◽  
Hyeon-Cheol Kim

Nickel-titanium (NiTi) endodontic rotary instruments are used extensively in root canal procedures by both general dentists and specialists. However, their vulnerability to fracture is the major reason for clinicians’ concern regarding their use. The objective of this study was to investigate the potential effects of spring machining of the file shaft on the fatigue and torsional resistances of NiTi rotary instruments. Three types of NiTi rotary systems with (S) and without (NS) spring machining were used in this study (n = 15 each): a spring file (SPR; #25/.06, SPR-S, SPR-NS), a ProTaper Next X2 (PTN; #25/variable taper, PTN-S, PTN-NS), and a ProTaper Gold F2 (PTG; #25/variable taper, PTG-S, PTG-NS). Spring machining was adjusted on the 6 mm of each file system’s shaft via a laser cutting process. The number of rotation cycles until fracture (i.e., cyclic fatigue resistance), ultimate torsional strength, the distortion angle, and the toughness of each subgroup were estimated with specially designed devices. The results were analyzed using a paired t-test at a significance level of 95%. NiTi rotary instruments with spring machining exhibited a higher cyclic fatigue resistance than instruments without spring machining. The groups with spring machining exhibited a higher toughness and larger distortion angle than the groups without it (p < 0.05). In conclusion, spring machining on the shank of NiTi instruments may provide a stress-bearing area and attenuate the torsional and cyclic fatigue of NiTi rotary instruments.


2021 ◽  
Vol 19 ◽  
pp. 228080002098740
Author(s):  
Haiyun Liu ◽  
Yanfeng Li ◽  
Guangquan Chai ◽  
Yuan Lv ◽  
Changjian Li ◽  
...  

Objective: To evaluate the effect of synchronous water irrigation on the fatigue resistance of nickel-titanium instrument. Methods: A standardized cyclic fatigue test models were established, and five types of nickel-titanium instruments (PTU F1, WO, WOG, RE, and M3) were applied. Each instrument was randomly divided into two groups ( N = 12). There was synchronous water irrigation in the experimental group, and no water irrigation in the control group. Besides, ProTaper Universal F1 was randomly divided into 10 groups ( N = 20). In the static group, nickel-titanium instruments were divided into one control group (no irrigation, N = 20) and six experimental group (irrigation, N = 20) based on different flow rate, angle and position; while in the dynamic group, instruments were divided into one control group (no irrigation, N = 20) and two experimental group (irrigation, N = 20) based on different flow rate. The rotation time (Time to Failure, TtF) of instruments was recorded and analyzed. Results: According to the static experiments, the TtF of instruments in all experimental groups was significantly higher than that in the static control group. Besides, the dynamic tests of PTU F1 showed that the TtF in the experimental group was significantly higher than that in the dynamic control group. Compared with control group, the TtF in the experimental groups increased by at least about 30% and up to 160%. The static and dynamic tests of PTU F1 showed that the TtF of nickel-titanium instrument in all experimental groups was significantly higher than that in the control group. However, there was no significant difference between any two experimental groups. Conclusion: Regardless of dynamic or static model, TtF with irrigation was longer than that with non-irrigation, indicating that synchronous irrigation can increase the fatigue resistance of nickel-titanium instrument. However, different irrigation conditions may have the same effect on the fatigue resistance.


Author(s):  
Giusy Rita Maria La Rosa ◽  
Carlotta Palermo ◽  
Sebastiano Ferlito ◽  
Gaetano Isola ◽  
Francesco Indelicato ◽  
...  

Materials ◽  
2020 ◽  
Vol 13 (24) ◽  
pp. 5823
Author(s):  
Saulius Drukteinis ◽  
Vytaute Peciuliene ◽  
Ruta Bendinskaite ◽  
Vilma Brukiene ◽  
Rasmute Maneliene ◽  
...  

The better understanding of the clinically important behavioral features of new instrument systems has an important significance for the clinical endodontics. This study aimed to investigate the shaping and centering ability as well as cyclic fatigue resistance of HyFlex CM (CM), HyFlex EDM (EDM) and EdgeFile (EF) thermally treated nickel–titanium (NiTi) endodontic instrument systems. Sixty curved root canals of the mesial roots of mandibular molars were randomly assigned into three groups (n = 20) and shaped using CM, EDM and EF files up to the size 40 and taper 04 of the instruments. µCT scanning of the specimens before and after preparation was performed and the morphometric 2D and 3D parameters were evaluated in the apical, middle and coronal thirds of root canals. In each group, 40.04 instruments (n = 20) were subjected to the cyclic fatigue resistance test in artificial root canals at 37 °C temperature until fractures occurred, and the number of cycles to failure (NCF) was calculated. The fractographic analysis was performed using a scanning electron microscope, evaluating topographic features and surface profiles of the separated instruments. The one-way analysis of variance with post hoc Tuckey’s test was used for statistical analysis of the data; the significance level was set at 5%. All systems prepared the comparable percentage of root canal surface with the similar magnitude of canal transportation in all root thirds (p > 0.05), but demonstrated significantly different resistance to cyclic fatigue (p < 0.05). The most resistant to fracture was EF, followed by EDM and CM. The length of the fractured fragments was not significantly different between the groups, and fractographic analysis by SEM detected the typical topographic features of separated thermally treated NiTi instrument surfaces.


2018 ◽  
Vol 12 (4) ◽  
pp. 283-287 ◽  
Author(s):  
Gülşah Uslu ◽  
Taha Özyürek ◽  
Mustafa Gündoğar ◽  
Koray Yılmaz

Background. The aim of this study was to compare the cyclic fatigue resistance of 2Shape, Twisted File (TF) and EndoSequence Xpress (ESX) nickel-titanium rotary files at intracanal temperature (35°C). Methods. Twenty 2Shape TS1 (25/.04), 20 TF (25/.04) and 20 ESX (25/.04) files were tested for cyclic fatigue at intracanal temperature (35°C). All the instruments were rotated in artificial canals which were made of stainless steel with an inner diameter of 1.5 mm, 60° angle of curvature and a radius curvature of 5 mm until fracture occurred; the time to fracture was recorded in seconds using a digital chronometer and the number of cycles to fracture (NCF) for each file was calculated. Kruskal-Wallis test with Bonferroni correction was performed to statistically analyze data using SPSS 21.0. Statistical significance was set at P<0.05. Results. NCF values revealed that the 2Shape had significantly the highest cyclic fatigue resistance, followed by TF and ESX at intracanal temperature (P<0.05). The difference was significant between the TF and ESX groups (P<0.05). There was no significant difference among the 2Shape, TF and ESX files with respect to the lengths of the fractured file fragments (P>.05). Conclusion. Within the limitations of present study, it was concluded that the cyclic fatigue resistance of 2Shape files at the intracanal temperature is higher than that of TF and ESX files.


Author(s):  
Jader Camilo Pinto ◽  
Fernanda Ferrari Esteves Torres ◽  
Airton Oliveira Santos-Junior ◽  
Marco Antonio Hungaro Duarte ◽  
Juliane Maria Guerreiro-Tanomaru ◽  
...  

Abstract Objective The aim of this study was to investigate the effect of additional apical preparation using the ProDesign Logic (PDL) 50/.01 rotary heat-treated nickel–titanium (NiTi) file with a larger diameter and minimal taper for retreatment of curved root canals. Materials and Methods Mesial curved root canals of 12 mandibular molars were prepared using PDL 25/.06 and filled using the continuous wave of condensation technique and AH Plus sealer. After retreatment using ProDesign S (PDS) 25/.08, PDL 25/.06 and PDL 35/05, a complementary procedure was performed with PDL 50/.01. Microcomputed tomography (micro-CT) scanning was performed before and after retreatment procedures. The cyclic fatigue resistance of unused PDS 25/.08, PDL 25/.06, PDL 35/.05 and PDL 50/.01 instruments (n = 12) was evaluated in a stainless-steel device. Statistical Analysis Data on the volumes of the root canals and the remaining filling materials were submitted to the paired t-test. Cyclic fatigue resistance data was submitted to one-way ANOVA and Tukey’s tests (α = 0.05). Results Use of PDL 50/.01 decreased the remaining filling materials in the apical third (p < 0.05). The root canal volume was similar in the cervical and middle thirds before and after preparation using PDL 50/.01 (p > 0.05). PDL 50/.01 presented the highest cyclic fatigue resistance (p < 0.05). Conclusions Use of the PDL 50/.01 instrument as an additional apical preparation for retreatment of curved root canals improved filling material removal in the apical third, while maintaining the dentin in the cervical and middle thirds. In addition, PDL 50/.01 presented high-flexural resistance.