scholarly journals Performance of a Point-of-Care Test for the Rapid Detection of SARS-CoV-2 Antigen

2020 ◽  
Vol 9 (1) ◽  
pp. 58
Author(s):  
Annabelle Strömer ◽  
Ruben Rose ◽  
Miriam Schäfer ◽  
Frieda Schön ◽  
Anna Vollersen ◽  
...  

The rapid detection of infections caused by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is necessary in the ongoing pandemic. Antigen-specific point-of-care tests (POCT) may be useful for this purpose. Here, such a POCT (SARS-CoV-2 NADAL® COVID-19 Ag) was compared to a laboratory-developed triplex real-time polymerase chain reaction (RT-PCR) designed for the detection of viral nucleoprotein gene and two control targets. This RT-PCR served as a reference to investigate POCT sensitivity by re-testing upper respiratory tract (URT) samples (n = 124) exhibiting different SARS-CoV-2 loads in terms of RT-PCR threshold cycle (Ct) values. The optical intensities of the antigen bands were compared to the Ct values of the RT-PCR. The infectivity of various virus loads was estimated by inoculating Vero cells with URT samples (n = 64, Ct 17-34). POCT sensitivity varied from 100% (Ct < 25) to 73.1% (Ct ≤ 30); higher SARS-CoV-2 loads correlated with higher band intensities. All samples with a Ct > 30 were negative; among SARS-CoV-2 free samples (n = 10) no false-positives were detected. A head-to-head comparison with another POCT (Abbott, Panbio™ COVID-19 Ag Rapid Test) yielded similar results. Isolation of SARS-CoV-2 in cell-culture was successful up to a Ct value of 29. The POCT reliably detects high SARS-CoV-2 loads and rapidly identifies infectious individuals.

Author(s):  
Ignacio Torres ◽  
Sandrine Poujois ◽  
Eliseo Albert ◽  
Javier Colomina ◽  
David Navarro

ABSTRACTObjectivesThere is limited information on the performance of rapid antigen detection (RAD) tests to identify SARS-CoV-2-infected asymptomatic individuals. In this field study, we evaluated the Panbio™ COVID-19 Ag Rapid Test Device (Abbott Diagnostics, Jena, Germany) for the purpose.MethodsA total of 634 individuals (355 female; median age, 37 years; range, 9-87) were enrolled. Household (n=338) contacts were tested at a median of 2 days (range, 1-7) after diagnosis of the index case and non-household contacts (n=296) at a median of 6 days (range, 1-7) after exposure. RAD testing was carried out at the point of care. The RT-PCR test used was the TaqPath COVID-19 Combo Kit (Thermo Fisher Scientific, Massachusetts, USA).ResultsIn total, 79 individuals (12.4%) tested positive by RT-PCR, of whom 38 (48.1%) yielded positive RAD results. The overall sensitivity and specificity of the RAD test was 48.1% (95% CI: 37.4-58.9) and 100% (95% CI: 99.3-100), respectively. Sensitivity was higher in household (50.8%; 95% CI: 38.9-62.5) than in non-household (35.7%; 95% CI:16.3-61.2%) contacts. Individuals testing positive by RAD test were more likely (P<0.001) to become symptomatic than their negative counterparts.ConclusionThe Panbio test displays low sensitivity in asymptomatic close contacts of COVID-19 patients, particularly in non-household contacts. Nonetheless, establishing the optimal timing for upper respiratory tract collection in this group seems imperative to pinpoint test sensitivity.


2018 ◽  
Vol 14 (3) ◽  
pp. 229-240
Author(s):  
Johanna Lindell

As antibiotic resistance becomes a growing health emergency, effective strategies are needed to reduce inappropriate antibiotic use. In this article, one such strategy – communicative practices associated with the C-reactive protein point-of care test – is investigated. Building on a collection of 31 videorecorded consultations from Danish primary care, and using conversation analysis, this study finds that the rapid test can be used throughout the consultation to incrementally build the case for a nonantibiotic treatment recommendation, both when the test result is forecast and reported. The study also finds that the format of reports of elevated results differs from that of ‘normal’ results, resulting in a subtle shift of authority from doctor to test.


2021 ◽  
Vol 104 (2) ◽  
pp. 003685042110261
Author(s):  
Sungwoo Choi ◽  
Hyo Jeong Choi ◽  
Ho Jung Kim

The most common method for SARS-CoV-2 testing is throat or nasal swabbing by real-time reverse transcription polymerase chain reaction (RT-PCR) assay. In South Korea, drive-through swab test is used for screening system and community treatment centers (CTCs), which admit and treat confirmed COVID-19 patients with mild symptoms, are being used. This retrospective study was conducted on patients admitted to a CTC on March 6, 2020. A total of 313 patients were admitted. The nasal and throat swabs were collected from the upper respiratory tract, and a sputum test was performed to obtain lower respiratory samples. The positive rate of the first set of test, sputum test was higher than that of the swab test ( p = 0.011). In the second set of test, 1 week after the first ones, the rate of positive swab tests was relatively high ( p = 0.026). In the first set of test, 66 of 152 (43.4%) patients showed 24-h consecutive negative swab test results, when the sputum test results were considered together, that number fell to 29 patients (19.1%) ( p < 0.001). Also, in the second set of test, 63 of 164 (38.4%) patients met the discharge criteria only when the swab test was considered; that number fell to 30 (18.3%) when the sputum test results were also considered ( p < 0.001). Using the swab test alone is insufficient for screening test and discharge decision. Patients who may have positive result in the sputum test can be missed.


Life ◽  
2021 ◽  
Vol 11 (6) ◽  
pp. 561
Author(s):  
Mariana Ulinici ◽  
Serghei Covantev ◽  
James Wingfield-Digby ◽  
Apostolos Beloukas ◽  
Alexander G. Mathioudakis ◽  
...  

While molecular testing with real-time polymerase chain reaction (RT-PCR) remains the gold-standard test for COVID-19 diagnosis and screening, more rapid or affordable molecular and antigen testing options have been developed. More affordable, point-of-care antigen testing, despite being less sensitive compared to molecular assays, might be preferable for wider screening initiatives. Simple laboratory, imaging and clinical parameters could facilitate prognostication and triage. This comprehensive review summarises current evidence on the diagnostic, screening and prognostic tests for COVID-19.


Author(s):  
Fadi Haddad ◽  
Christopher C Lamb ◽  
Ravina Kullar ◽  
George Sakoulas

Background: Covid-19 remains a pandemic with multiple challenges to confirm patient infectivity: lack of sufficient tests, accurate results, validated quality, and timeliness of results. We hypothesize that a rapid 15-minute Point-Of-Care serological test to evaluate past infection complements diagnostic testing for Covid-19 and significantly enhances testing availability. Method: A three arm observational study at Sharp Healthcare, San Diego, California was conducted using the Clungene® lateral flow immunoassay (LFI) and compared with the Cobas® Roche RT PCR results. Arm 1: Thirty-five (35) subjects with confirmed Covid-19 using RT-PCR were tested twice: prior to 14 days following symptom onset and once between 12 and 70 days. Arm 2: Thirty (30) subjects with confirmed Covid-19 using RT-PCR were tested 12-70 days post symptom onset. Arm 3: Thirty (30) subjects with a negative RT-PCR for Covid-19 were tested 1-10 days following the RT-PCR test date. Results: Specificity of confirmed negative Covid-19 by RT-PCR was 100% (95% CI, 88.4%-100.0%); meaning there was 100% negative positive agreement between the RT-PCR and the Clungene® serological test results. Covid-19 subjects tested prior to day 7 symptom onset were antibody negative. In subjects 7-12 days following symptom onset with a confirmed positive Covid-19 by RT-PCR, the combined sensitivity of IgM and IgG was 58.6% (95% CI, 38.9%-76.5%). In subjects 13-70 days following symptom onset with a confirmed positive Covid-19 by RT-PCR the combined sensitivity of IgM and IgG was 90.5% (95% CI, 80.4%-96.4%). Conclusion: The Clungene® lateral flow immunoassay (LFI) is a useful tool to confirm individuals with an adaptive immune response to SARS-CoV-2 indicating past infection. Providing Point-Of-Care results within 15 minutes without any laboratory instrumentation or specialized software has an added value of increasing test availability to patients who have been symptomatic for more than one week to confirm past infection. Performance characteristics are optimal after 13 days with a sensitivity and specificity of 90% and 100%, respectively.


Viruses ◽  
2019 ◽  
Vol 11 (8) ◽  
pp. 697 ◽  
Author(s):  
Julia Frankenfeld ◽  
Theres Meili ◽  
Marina Meli ◽  
Barbara Riond ◽  
A. Helfer-Hungerbuehler ◽  
...  

Feline immunodeficiency virus (FIV) is a lentivirus of domestic cats worldwide. Diagnosis usually relies on antibody screening by point-of-care tests (POCT), e.g., by enzyme-linked immunosorbent assays (ELISA), and confirmation using Western blot (WB). We increasingly observed ELISA-negative, WB-positive samples and aimed to substantiate these observations using 1194 serum/plasma samples collected from 1998 to 2019 primarily from FIV-suspect cats. While 441 samples tested positive and 375 tested negative by ELISA and WB, 81 samples had discordant results: 70 were false ELISA-negative (WB-positive) and 11 were false ELISA-positive (WB-negative); 297 ambiguous results were not analyzed further. The diagnostic sensitivity and specificity of the ELISA (82% and 91%, respectively) were lower than those reported in 1995 (98% and 97%, respectively). The diagnostic efficiency was reduced from 97% to 86%. False ELISA-negative samples originated mainly (54%) from Switzerland (1995: 0%). Sixty-four false ELISA-negative samples were available for POCT (SNAPTM/WITNESSR): five were POCT-positive. FIV RT-PCR was positive for two of these samples and was weakly positive for two ELISA- and POCT-negative samples. Low viral loads prohibited sequencing. Our results suggest that FIV diagnosis has become more challenging, probably due to increasing travel by cats and the introduction of new FIV isolates not recognized by screening assays.


2020 ◽  
Vol 59 (9-10) ◽  
pp. 856-858
Author(s):  
Gregory DeMuri ◽  
Ellen R. Wald

Rapid turnaround real-time polymerase chain reaction (PCR) has recently become available as a point-of-care test for group A Streptococcus (GAS) in children presenting with pharyngitis. Our aim in this pilot study was to determine if GAS can be detected in the saliva of children with sore throat using swabs inoculated by children sucking on them as they would a lollipop. Twenty children with positive rapid antigen detection tests for GAS from pharyngeal swabs were enrolled. Pharyngeal and lollipop samples underwent PCR testing using the cobas Liat system. All 20 pharyngeal swabs were positive; 19 of 20 lollipop samples were positive. The increased sensitivity of the new PCR kits for GAS may permit use of less invasive and more comfortable sampling techniques for diagnosis.


2019 ◽  
Vol 2019 ◽  
pp. 1-5 ◽  
Author(s):  
Kristina Baraba Dekanić ◽  
Ivona Butorac Ahel ◽  
Lucija Ružman ◽  
Jasmina Dolinšek ◽  
Jernej Dolinšek ◽  
...  

Introduction. Celiac disease (CD) is an autoimmune disease triggered by gluten in genetically predisposed individuals. Despite the increasing prevalence of CD, many patients remain undiagnosed. Standard serology tests are expensive and invasive, so several point-of-care tests (POC) for CD have been developed. We aimed to determine the prevalence of CD in first-grade pupils in Primorje-Gorski Kotar County, Croatia, using a POC test. Methods. A Biocard celiac test that detects IgA antibodies to tissue transglutaminase in whole blood was used to screen for celiac disease in healthy first-grade children born in 2011 and 2012 who consumed gluten without restrictions. Results. 1478 children were tested, and none of them were tested positive with a rapid test. In 10 children (0,6%), IgA deficiency has been suspected; only 4 of them agreed to be tested further for total IgA, anti-tTG, and anti-DGP antibodies. IgA deficiency was confirmed in 3 patients, and in all 4 children, CD has been excluded. Conclusion. Our results have not confirmed the usefulness of the POC test in screening the general population of first-grade schoolchildren. Further research is needed to establish the true epidemiology of CD in Primorje-Gorski Kotar County and to confirm the value of the rapid test in comparison with standard antibody CD testing.


2016 ◽  
Vol 28 (7) ◽  
pp. 702-707 ◽  
Author(s):  
Stephen C Davies ◽  
Andrew Koh ◽  
Heather E Lindsay ◽  
Richard B Fulton ◽  
Suran L Fernando

An inner Sydney sexual health service introduced the option to gay and bisexual men of receiving a negative HIV result by SMS to mobile phone one business day after venipuncture (rapid SMS). Men could also choose one of the other options: a point-of-care-test (POCT), by phone, or in-person (clinicians could also require in-person). We followed-up patients choosing the rapid SMS method to ascertain their satisfaction. During 12 months, 473 men had 591 HIV tests. Of these tests, 5.4% were POCTs, 9.1% were in-person, 24% were by phone, and 62% were rapid SMS. HIV POCTs declined from being 22% of result methods in the pre-study period to 5.4% during the rapid SMS intervention period (odds ratio 0.20, 95% CI 0.13–0.32, P < 0.0001). Phone/in-person results declined from 78% to 33% (odds ratio 0.14, 95% CI 0.10–0.20, P < 0.0001). SMS was sent by the next business day in 95% of cases; 96% of men were satisfied; and 95% would choose this method for their next test. Of 77 men who previously had an HIV POCT, 56 (73%) elected a rapid SMS result rather than having another POCT. The higher accuracy of conventional serology was commonly expressed as the reason for choosing rapid SMS for results.


Sensors ◽  
2020 ◽  
Vol 20 (15) ◽  
pp. 4289 ◽  
Author(s):  
Heba A. Hussein ◽  
Rabeay Y. A. Hassan ◽  
Marco Chino ◽  
Ferdinando Febbraio

Coronaviruses have received global concern since 2003, when an outbreak caused by SARS-CoV emerged in China. Later on, in 2012, the Middle-East respiratory syndrome spread in Saudi Arabia, caused by MERS-CoV. Currently, the global crisis is caused by the pandemic SARS-CoV-2, which belongs to the same lineage of SARS-CoV. In response to the urgent need of diagnostic tools, several lab-based and biosensing techniques have been proposed so far. Five main areas have been individuated and discussed in terms of their strengths and weaknesses. The cell-culture detection and the microneutralization tests are still considered highly reliable methods. The genetic screening, featuring the well-established Real-time polymerase chain reaction (RT-PCR), represents the gold standard for virus detection in nasopharyngeal swabs. On the other side, immunoassays were developed, either by screening/antigen recognition of IgM/IgG or by detecting the whole virus, in blood and sera. Next, proteomic mass-spectrometry (MS)-based methodologies have also been proposed for the analysis of swab samples. Finally, virus-biosensing devices were efficiently designed. Both electrochemical immunosensors and eye-based technologies have been described, showing detection times lower than 10 min after swab introduction. Alternative to swab-based techniques, lateral flow point-of-care immunoassays are already commercially available for the analysis of blood samples. Such biosensing devices hold the advantage of being portable for on-site testing in hospitals, airports, and hotspots, virtually without any sample treatment or complicated lab precautions.