scholarly journals Comparison of Above-Water Seabird and TriOS Radiometers along an Atlantic Meridional Transect

2020 ◽  
Vol 12 (10) ◽  
pp. 1669
Author(s):  
Krista Alikas ◽  
Viktor Vabson ◽  
Ilmar Ansko ◽  
Gavin H. Tilstone ◽  
Giorgio Dall’Olmo ◽  
...  

The Fiducial Reference Measurements for Satellite Ocean Color (FRM4SOC) project has carried out a range of activities to evaluate and improve the state-of-the-art in ocean color radiometry. This paper described the results from a ship-based intercomparison conducted on the Atlantic Meridional Transect 27 from 23rd September to 5th November 2017. Two different radiometric systems, TriOS-Radiation Measurement Sensor with Enhanced Spectral resolution (RAMSES) and Seabird-Hyperspectral Surface Acquisition System (HyperSAS), were compared and operated side-by-side over a wide range of Atlantic provinces and environmental conditions. Both systems were calibrated for traceability to SI (Système international) units at the same optical laboratory under uniform conditions before and after the field campaign. The in situ results and their accompanying uncertainties were evaluated using the same data handling protocols. The field data revealed variability in the responsivity between TRiOS and Seabird sensors, which is dependent on the ambient environmental and illumination conditions. The straylight effects for individual sensors were mostly within ±3%. A near infra-red (NIR) similarity correction changed the water-leaving reflectance (ρw) and water-leaving radiance (Lw) spectra significantly, bringing also a convergence in outliers. For improving the estimates of in situ uncertainty, it is recommended that additional characterization of radiometers and environmental ancillary measurements are undertaken. In general, the comparison of radiometric systems showed agreement within the evaluated uncertainty limits. Consistency of in situ results with the available Sentinel-3A Ocean and Land Color Instrument (OLCI) data in the range from (400…560) nm was also satisfactory (−8% < Mean Percentage Difference (MPD) < 15%) and showed good agreement in terms of the shape of the spectra and absolute values.

2021 ◽  
Vol 13 (14) ◽  
pp. 2673
Author(s):  
Adam Lawson ◽  
Jennifer Bowers ◽  
Sherwin Ladner ◽  
Richard Crout ◽  
Christopher Wood ◽  
...  

The satellite validation navy tool (SAVANT) was developed by the Naval Research Laboratory to help facilitate the assessment of the stability and accuracy of ocean color satellites, using numerous ground truth (in situ) platforms around the globe and support methods for match-up protocols. The effects of varying spatial constraints with permissive and strict protocols on match-up uncertainty are evaluated, in an attempt to establish an optimal satellite ocean color calibration and validation (cal/val) match-up protocol. This allows users to evaluate the accuracy of ocean color sensors compared to specific ground truth sites that provide continuous data. Various match-up constraints may be adjusted, allowing for varied evaluations of their effects on match-up data. The results include the following: (a) the difference between aerosol robotic network ocean color (AERONET-OC) and marine optical Buoy (MOBY) evaluations; (b) the differences across the visible spectrum for various water types; (c) spatial differences and the size of satellite area chosen for comparison; and (d) temporal differences in optically complex water. The match-up uncertainty analysis was performed using Suomi National Polar-orbiting Partnership (SNPP) Visible Infrared Imaging Radiometer Suite (VIIRS) SNPP data at the AERONET-OC sites and the MOBY site. It was found that the more permissive constraint sets allow for a higher number of match-ups and a more comprehensive representation of the conditions, while the restrictive constraints provide better statistical match-ups between in situ and satellite sensors.


Author(s):  
Mikhail A. Sokolov

Mini-CT specimens are becoming a highly popular geometry for use in reactor pressure vessel (RPV) community for direct measurement of fracture toughness in the transition region using the Master Curve methodology. In the present study, Mini-CT specimens were machined from previously tested Charpy specimens of the Midland low upper-shelf Linde 80 weld in both, unirradiated and irradiated conditions. The irradiated specimens have been characterized as part of a joint ORNL-EPRI-CRIEPI collaborative program. The Linde 80 weld was selected because it has been extensively characterized in the irradiated condition by conventional specimens, and because of the need to validate application of Mini-CT specimens for low upper-shelf materials — a more likely case for some irradiated materials of older generation RPVs. It is shown that the fracture toughness reference temperatures, To, derived from these Mini-CT specimens are in good agreement with To values previously recorded for this material in the unirradiated and irradiated conditions. However, this study indicates that in real practice it is highly advisable to use a much larger number of specimens than the minimum number prescribed in ASTM E1921.


2020 ◽  
Author(s):  
Ali Fallah ◽  
Sungmin O ◽  
Rene Orth

Abstract. Precipitation is a crucial variable for hydro-meteorological applications. Unfortunately, rain gauge measurements are sparse and unevenly distributed, which substantially hampers the use of in-situ precipitation data in many regions of the world. The increasing availability of high-resolution gridded precipitation products presents a valuable alternative, especially over gauge-sparse regions. Nevertheless, uncertainties and corresponding differences across products can limit the applicability of these data. This study examines the usefulness of current state-of-the-art precipitation datasets in hydrological modelling. For this purpose, we force a conceptual hydrological model with multiple precipitation datasets in > 200 European catchments. We consider a wide range of precipitation products, which are generated via (1) interpolation of gauge measurements (E-OBS and GPCC V.2018), (2) combination of multiple sources (MSWEP V2) and (3) data assimilation into reanalysis models (ERA-Interim, ERA5, and CFSR). For each catchment, runoff and evapotranspiration simulations are obtained by forcing the model with the various precipitation products. Evaluation is done at the monthly time scale during the period of 1984–2007. We find that simulated runoff values are highly dependent on the accuracy of precipitation inputs, and thus show significant differences between the simulations. By contrast, simulated evapotranspiration is generally much less influenced. The results are further analysed with respect to different hydro-climatic regimes. We find that the impact of precipitation uncertainty on simulated runoff increases towards wetter regions, while the opposite is observed in the case of evapotranspiration. Finally, we perform an indirect performance evaluation of the precipitation datasets by comparing the runoff simulations with streamflow observations. Thereby, E-OBS yields the best agreement, while furthermore ERA5, GPCC V.2018 and MSWEP V2 show good performance. In summary, our findings highlight a climate-dependent propagation of precipitation uncertainty through the water cycle; while runoff is strongly impacted in comparatively wet regions such as Central Europe, there are increasing implications on evapotranspiration towards drier regions.


2019 ◽  
Vol 11 ◽  
Author(s):  
A. G. Karydas ◽  
T. Pantazis ◽  
C. Doumas ◽  
A. Vlachopoulos ◽  
P. Nomikos ◽  
...  

In-situ X-ray fluorescence analysis (XRF) of ancient artifacts from the excavation area was performed using a novel X-ray instrumentation, composed of a portable silicon PIN thermoelectrically cooled X-ray detector, a miniature X-ray source, and portable data acquisition devices. The main objective of the analyses in Akrotiri was to explore the potential of the technique to provide answers to a wide range of archaeometric questions regarding the bulk composition of metal alloys, especially of gold, the characterization of corrosion products in bronze artifacts, identification of inorganic elements which are fingerprints of the minerals used in wall-painting pigments, and of the painting materials and techniques used for the decoration of clay vase surfaces. Among the analysed artifacts are a unique gold ibex, a bronze dagger and blade, various pigments from the wall paintings of room 3 in Xeste 3, decoration pigments from rosettes of faience, a bichrome jug, and other clay vases. The results of the in-situ XRF survey, primarily those of the bulk composition and soldering technology of the gold ibex, are discussed and compared with literature.


Nanoscale ◽  
2018 ◽  
Vol 10 (48) ◽  
pp. 22792-22801 ◽  
Author(s):  
Hans Vanrompay ◽  
Eva Bladt ◽  
Wiebke Albrecht ◽  
Armand Béché ◽  
Marina Zakhozheva ◽  
...  

The thermal reshaping and its influence on the plasmonic properties of gold nanostars are investigated using a combination of in situ tomography and a state-of-the-art fast acquisition approach.


1993 ◽  
Vol 70-71 ◽  
pp. 211-216 ◽  
Author(s):  
Claudia L. Bianchi ◽  
Maria G. Cattania ◽  
Pierangela Villa

2014 ◽  
Vol 70 (a1) ◽  
pp. C1734-C1734
Author(s):  
Zoltan Gal ◽  
Tadeusz Skarzynski ◽  
Fraser White ◽  
Oliver Presly ◽  
Adrian Jones ◽  
...  

Agilent Technologies develop and supply X-ray systems for single-crystal diffraction research, including the SuperNova; a compact, highly reliable and very low maintenance instrument providing X-ray data of the highest quality; and the PX Scanner for testing and characterization of protein crystals in their original crystallization drops (in-situ). The SuperNova and PX Scanner are constantly improving, with recent enhancements including a new range of detectors using an Intelligent Measurement System. The Eos S2, Atlas S2 and Titan S2 detector range employs a smart sensitivity control of the electronic gain and is capable of instantaneously switching its binning modes thus providing unprecedented flexibility in tuning every exposure to provide the highest data quality for a wide range of experiments. We have also developed a completely new micro-focus X-ray source based on Gradient Vacuum technology, with novel filament and target designs. This novel source is an integral part of the new Agilent GV1000 X-ray diffractometer, which has been designed for applications that require even higher brightness of the X-ray beam.


1983 ◽  
Vol 29 (2) ◽  
pp. 362-365 ◽  
Author(s):  
J Egberts ◽  
W Soederhuizen ◽  
D O Gebhardt

Abstract A rapid (30-min) semiautomated continuous-flow procedure is described for use in assessing the phospholipids of the particulate ("lamellar body") fraction of human amniotic fluid. The method is based on measuring the difference in fluorescence of 1,6,-diphenyl-1,3,5-hexatriene added to amniotic fluid before and after micropore filtration. The filtration step removes "lamellar body" particles, which are considered to contain the fetal lung surfactant. The phospholipid values for the filtered particles are independent of background fluorescence, which increases when amniotic fluid is contaminated by bilirubin pigments or blood components. Over a wide range (3-150 mumols/L) the fluorescence increases linearly with the phospholipid concentration of the amniotic fluid. There is a good agreement between the value for particulate "lamellar body" phospholipid, the ratio of the "lamellar body" phospholipids to total amniotic fluid phospholipids, and the lecithin/sphingomyelin ratio.


2016 ◽  
Vol 66 (4) ◽  
pp. 323 ◽  
Author(s):  
Jitendra Gangwar ◽  
Bipin Kumar Gupta ◽  
Avanish Kumar Srivastava

<p>This review article mainly focused on the recent progress on the synthesis and characterization of emerging artificially engineered nanostructures of oxide materials as well as their potential applications. A fundamental understanding about the state-of-the-art of the synthesis for different size, shape and morphology, which can be tuned to the desired properties of oxide nanomaterials have discussed in details in this review. The present review covers the a wide range of artificially engineered oxide nanomaterials such as cadmium-, cupric-, nickel-, magnesium-, zinc-, titanium-, tin-, aluminium-, and vanadium-oxides and their useful applications in sensors, optical displays, nanofluids and defence.</p>


2018 ◽  
Vol 18 (2) ◽  
pp. 80-95
Author(s):  
H. Danninger ◽  
G. Leitner ◽  
Ch. Gierl-Mayer

Abstract In situ characterization of the sintering process is a difficult task, in particular for systems without pronounced dimensional changes. Dilatometry is not too helpful in those cases, and therefore other properties have to be recorded. In the present study, sintering of ferrous powder compacts was studied in situ by measuring the thermal diffusivity a using a laser flash apparatus. This property is a measure to characterise the heat flow through a material; it depends on the contact area between the particles and thus reveals their change during sintering. It is shown that the change of a during sintering of ferrous compacts is much less pronounced than in the case of cemented carbides which is not surprising when regarding the widely differing porosity changes. The results are however in good agreement with expectations when considering some experimental limitations. The trend for the thermal conductivity λ. which can be calculated from a, the specific heat and the density, is in good agreement with that found for the electrical conductivity, both properties being linked through Wiedemann-Franz’ law.


Sign in / Sign up

Export Citation Format

Share Document