scholarly journals Expansion of Sewer, Water and District Heating Networks in Cold Climate Regions: An Integrated Sustainability Assessment

2018 ◽  
Vol 10 (10) ◽  
pp. 3743 ◽  
Author(s):  
Youen Pericault ◽  
Erik Kärrman ◽  
Maria Viklander ◽  
Annelie Hedström

This study presents an integrated sustainability assessment of technical alternatives for water and heating services provision in suburban areas affected by a cold climate. Each alternative combines a drinking water supply, sewerage (gravity or low-pressure), pipe freeze protection (deep burial or shallow burial with heat tracing) and heating solution (district heating or geothermal heat pumps). An innovative freeze protection option was considered, in which low-temperature district heating (LTDH) is used to heat trace shallow sewer and water pipes. First, the performance of each alternative regarding seven sustainability criteria was evaluated on a projected residential area in Sweden using a systems analysis approach. A multi-criteria method was then applied to propose a sustainability ranking of the alternatives based on a set of weights obtained from local stakeholders. The alternative with a deep buried gravity sewer and geothermal heat pumps was found to have the highest sustainability score in the case study. In the sensitivity analysis, the integrated trench solution with a gravity sewer, innovative heat tracing and LTDH was found to potentially top the sustainability ranking if geothermal energy was used as the district heating source, or if the weight of the cost criterion increased from 24% to 64%. The study highlights the need for integrated decision-making between different utility providers as an integrated solution can represent sustainability gains.

Energy ◽  
2017 ◽  
Vol 137 ◽  
pp. 865-877 ◽  
Author(s):  
Jonas K. Jensen ◽  
Torben Ommen ◽  
Wiebke B. Markussen ◽  
Brian Elmegaard

2021 ◽  
Vol 288 ◽  
pp. 01089
Author(s):  
Alexei Sednin ◽  
Aliaksandr Mukhin ◽  
Boris Balakin

Future district heating systems need to be more flexible and move towards a carbon-neutral generation. Compression heat pumps are foreseen to be promising future tools for district heating systems in EU countries. The paper presents the simulation data or a vertical double-pipe geothermal heat exchanger with ethylene glycol-Al2O3 as a working fluid. To simulate the operation of the heat exchanger, the STAR-CCM + CFD application was used. It has been determined the optimal volume particle concentrations of nanofluid and enhance of heat exchanger performance.


2021 ◽  
Vol 13 (6) ◽  
pp. 3370
Author(s):  
Lauma Balode ◽  
Kristiāna Dolge ◽  
Dagnija Blumberga

The blind spot can be defined as the area around the vehicle where the driver cannot see through the mirrors without turning their head or taking their eyes off the road. Similar blind spots occur in energy policy. Blind spots can occur in forecasting economic development and creating policy documents. This study uncovers potential blind spots and controversies in the sustainability assessment of energy supply technologies. A composite sustainability index was constructed to compare district heating with four individual heating technologies—wood pellet boilers, natural gas boilers, solar collectors, and heat pumps. A total of 19 indicators were selected and grouped into four dimensions of sustainability—technical, environmental, economic, and social. The results reveal that district heating can compete with individual heating technologies in all dimensions of sustainability; however, a possible blind spot lies in evaluating environmental performance indicators of the different heating technologies. This study provides a novel decision-making tool that policy-makers could use to identify and avoid potential blind spots and uncertainties in energy policy at an early stage.


Energies ◽  
2020 ◽  
Vol 13 (4) ◽  
pp. 954 ◽  
Author(s):  
Hanne Kauko ◽  
Daniel Rohde ◽  
Armin Hafner

District heating enables an economical use of energy sources that would otherwise be wasted to cover the heating demands of buildings in urban areas. For efficient utilization of local waste heat and renewable heat sources, low distribution temperatures are of crucial importance. This study evaluates a local heating network being planned for a new building area in Trondheim, Norway, with waste heat available from a nearby ice skating rink. Two alternative supply temperature levels have been evaluated with dynamic simulations: low temperature (40 °C), with direct utilization of waste heat and decentralized domestic hot water (DHW) production using heat pumps; and medium temperature (70 °C), applying a centralized heat pump to lift the temperature of the waste heat. The local network will be connected to the primary district heating network to cover the remaining heat demand. The simulation results show that with a medium temperature supply, the peak power demand is up to three times higher than with a low temperature supply. This results from the fact that the centralized heat pump lifts the temperature for the entire network, including space and DHW heating demands. With a low temperature supply, heat pumps are applied only for DHW production, which enables a low and even electricity demand. On the other hand, with a low temperature supply, the district heating demand is high in the wintertime, in particular if the waste heat temperature is low. The choice of a suitable supply temperature level for a local heating network is hence strongly dependent on the temperature of the available waste heat, but also on the costs and emissions related to the production of district heating and electricity in the different seasons.


Proceedings ◽  
2020 ◽  
Vol 65 (1) ◽  
pp. 25
Author(s):  
Antonio Garrido Marijuan ◽  
Roberto Garay ◽  
Mikel Lumbreras ◽  
Víctor Sánchez ◽  
Olga Macias ◽  
...  

District heating networks deliver around 13% of the heating energy in the EU, being considered as a key element of the progressive decarbonization of Europe. The H2020 REnewable Low TEmperature District project (RELaTED) seeks to contribute to the energy decarbonization of these infrastructures through the development and demonstration of the following concepts: reduction in network temperature down to 50 °C, integration of renewable energies and waste heat sources with a novel substation concept, and improvement on building-integrated solar thermal systems. The coupling of renewable thermal sources with ultra-low temperature district heating (DH) allows for a bidirectional energy flow, using the DH as both thermal storage in periods of production surplus and a back-up heating source during consumption peaks. The ultra-low temperature enables the integration of a wide range of energy sources such as waste heat from industry. Furthermore, RELaTED also develops concepts concerning district heating-connected reversible heat pump systems that allow to reach adequate thermal levels for domestic hot water as well as the use of the network for district cooling with high performance. These developments will be demonstrated in four locations: Estonia, Serbia, Denmark, and Spain.


Energy ◽  
2021 ◽  
pp. 121202
Author(s):  
Kristina Lygnerud ◽  
Jonas Ottosson ◽  
Johan Kensby ◽  
Linnea Johansson

2021 ◽  
Vol 298 ◽  
pp. 126799
Author(s):  
S. Smitt ◽  
I. Tolstorebrov ◽  
P. Gullo ◽  
A. Pardiñas ◽  
A. Hafner
Keyword(s):  

Energies ◽  
2021 ◽  
Vol 14 (9) ◽  
pp. 2347
Author(s):  
Elżbieta Hałaj ◽  
Jarosław Kotyza ◽  
Marek Hajto ◽  
Grzegorz Pełka ◽  
Wojciech Luboń ◽  
...  

Krakow has an extensive district heating network, which is approximately 900 km long. It is the second largest city in terms of the number of inhabitants in Poland, resulting in a high demand for energy—for both heating and cooling. The district heating of the city is based on coal. The paper presents the conception of using the available renewable sources to integrate them into the city’s heating system, increasing the flexibility of the system and its decentralization. An innovative solution of the use of hybrid, modular heat pumps with power dependent on the needs of customers in a given location and combining them with geothermal waters and photovoltaics is presented. The potential of deep geothermal waters is based on two reservoirs built of carbonate rocks, namely Devonian and Upper Jurassic, which mainly consist of dolomite and limestone. The theoretical potential of water intake equal to the nominal heating capacity of a geothermal installation is estimated at 3.3 and 2.0 MW, respectively. Shallow geothermal energy potential varies within the city, reflecting the complex geological structure of the city. Apart from typical borehole heat exchangers (BHEs), the shallower water levels may represent a significant potential source for both heating and cooling by means of water heat pumps. For the heating network, it has been proposed to use modular heat pumps with hybrid sources, which will allow for the flexible development of the network in places previously unavailable or unprofitable. In the case of balancing production and demand, a photovoltaic installation can be an effective and sufficient source of electricity that will cover the annual electricity demand generated by the heat pump installation, when it is used for both heating and cooling. The alternating demand of facilities for heating and cooling energy, caused by changes in the seasons, suggests potential for using seasonal cold and heat storage.


Sign in / Sign up

Export Citation Format

Share Document