Alternativa energética sustentable mediante la utilización de aislantes térmicos de diferentes materiales en edificaciones con sistemas de aire acondicionado
A methodology is proposed for calculating the cooling load and the energy consumption of air conditioning equipment in three scale models of buildings under study, using the ASHRAE CLTD / SCL / CLF method. The building in which the mentioned method is used are three scale models of buildings located in the city of Poza Rica, state of Veracruz, Mexico. This method is applied in order to obtain the cooling load as exact as possible and thus avoid oversizing in air conditioning equipment, and by using thermal insulation, achieve a decrease in energy consumption and thus contribute to the reduction of CO2 emissions, to energy saving and therefore to sustainable development. The cooling load is calculated by applying the proposed methodology to three cases: model A, B and C. The results for the three test models, object of this study, are compared. Measurements of energy consumption are made to perform the error analysis of the actual energy consumption with respect to that calculated using the method. Finally, energy savings are quantified, in the cases mentioned.