scholarly journals Assessment of the Sverdlovsk Oblast Drinking Water Pollution with Heavy Metal

Author(s):  

The paper presents the results of the determination of heavy metals in drinking water samples from centralized water supply systems and wells of individual water supply of the Sverdlovsk region. It was found that the content of copper ions in the samples does not exceed its maximum permissible concentration, and the content of lead and cadmium ions in most samples is higher than the permissible norms. It is established that water samples from Nizhny Tagil and Serov are more contaminated with cadmium. The causes of drinking water pollution are discussed. It was found that the pollution of water from the centralized water supply systems with heavy metals is mainly due to the non-compliance of the operated water pipes with sanitary and hygienic requirements. Groundwater pollution is caused by the infiltration of industrial effluents containing heavy metals from storage and sedimentation tanks through soil. It is shown that numerous industrial enterprises in the Sverdlovsk region aggravate the process of pollution of surface and groundwater with heavy metals. The unsatisfactory quality of water in terms of the content of heavy metals in Sverdlovsk region is revealed. The authors dwell on the need to continue research to determine the content of other heavy metals in water and expand the geography of sampling in the region in order to assess more accurately the quality of water.

2020 ◽  
Vol 841 ◽  
pp. 36-40
Author(s):  
Mardan Jalilov ◽  
Ayten Jalilova ◽  
Gulnar Feyziyeva ◽  
Makhanim Azimova

Given that the quality of water supplied to hot water supply systems must meet drinking water requirements, it is also important that the water preparation process is of great importance. The quality of that water is also important in terms of preventing the formation of heat in hot water systems. It is known that the main cause of the formation of water is the presence of calcium and magnesium cations and bicarbonate and sulfate anions in water. The traditional methods for preventing the limescale include the combination of calcium and magnesium cations from the water and replacing them with cations that are not easy to resolve at high temperatures. The quality of water treated by these methods does not meet drinking water requirements. Taking these into account, the Cl-anionizationprocess of drinking water has been developed in high-tech anionite technology. According to this technology, the first water from the city water gridis processed through anionite and activated carbon filters, which are mechanically charged with high anionite. The treated water is then cleaned out of microbes and bacteria through the ultraviolet disinfection equipment and delivered to the operator according to the quality requirements for drinking water. In the chlorine-anionization process, most of the sulfate and bicarbonate anions in water change to chlorine anions and their solidity remains constant. Thus, the density of the limescale-forming anions in the water decreases sharply and it meets the quality indicators of drinking water. High-grade anionite in the filter (8÷12) is regenerated by NaCl solution. The filtration rate of the solution from the anionite is determined depending on the concentration of calcium cations contained in the salt given for regeneration. Regeneration mode is such that the CaCO3 combination does not crumble when the anionite layer is formed. It is known that the temperature of the heated water in the hot water supply system does not exceed (60÷70)°C. In this case, the decomposition of limescale at Hc<2 mg-eq/l (carbonate hardness) is not observed. As carbonate hardness increases to 4 mg/l, the thin layer in the system shows a collapse. The basic element of the proposed technological schemeCl-anionite filter was applied at ADA University in Baku and positive results were obtained. Early observed collapse of pipes has been prevented and the working regime of hot water heaters has improved. A high-performance anionite such as A200EMBCl, which is a major ingredient of the UK's Purelite, and then the Russian-made AB-17-8 high-anionite anions have been used on the device.


2008 ◽  
Vol 6 (S1) ◽  
pp. 21-26 ◽  
Author(s):  
John Gray

Water supply companies in the UK have a duty under prime UK legislation to notify the Drinking Water Inspectorate of events affecting or potentially affecting the quality of drinking-water supplies. Under the same legislation, the Inspectorate has a duty to investigate each event. After assessing all of the information available, including companies' reports, the Inspectorate advises on the way in which the event was handled and whether any statutory requirements were contravened. If appropriate, a prosecution of the water company may be initiated. Copies of the assessment are sent to the water company, relevant local and health authorities, Ofwat (the economic regulator), the regional Consumer Council for Water and any other interested parties, including consumers who request it. Generic guidance may be issued to the industry on matters of wider concern. This paper considers the role of the Inspectorate, the powers available to it and reporting arrangements. An overview is presented of events that occurred between 1990 and 2005 and common features are identified. Causes of different types of event are discussed. The importance of well-established contacts between the various interested parties involved in protecting public health is emphasised through discussion of example incidents.


2021 ◽  
pp. 41-51
Author(s):  
O.V. Sazonova Sazonova ◽  
◽  
A.K. Sergeev ◽  
L.V. Chupakhina ◽  
T.K. Ryazanova ◽  
...  

Environmental contamination is still a pressing issue, in particular, contaminated drinking water sources and contaminated drinking water from centralized communal water supply systems, since it produces negative effects on human health. Our research goal was to estimate probable impacts exerted on overall morbidity in Samara by quality of drinking water taken from centralized communal water supply systems as a most significant environmental factor. Our research tasks included taking and analyzing drinking water samples from centralized communal water supply systems; calculating carcinogenic and non-carcinogenic health risks caused by analyzed chemicals. To fulfill the tasks and achieve the goals, in 2018–2019 we performed sanitary-chemical analysis of drinking water quality as per 20 sanitary-chemical parameters; our research object was drinking water taken from centralized communal water supply systems in 7 districts in Samara. Obtained actual data on contamination of water taken from centralized water supply networks in Samara were used as primary basis for calculating hazard indexes and carcinogenic risk coefficients using conventional exposure scenarios. In our research we revealed that maximum total non-carcinogenic hazard quotient was determined by arsenic and petroleum products introduction. Assessment of carcinogenic risks caused by contaminants in drinking water revealed that total health risk for children younger than 18 was within the second range as per its median; total carcinogenic risks for adults, within the third range. At the same time, arsenic contents did not exceed hygienic standards in all examined samples. So, we assessed carcinogenic and non-carcinogenic risks, basing on actual data on quality of drinking water taken from centralized communal water supply systems. It seems vital to perform a wider-scale controlled study in several regions in order to assess significance of revealed factors for morbidity among population.


2020 ◽  
Vol 99 (6) ◽  
pp. 563-568
Author(s):  
Yuliya A. Novikova ◽  
K. B. Friedman ◽  
V. N. Fedorov ◽  
A. A. Kovshov ◽  
N. A. Tikhonova ◽  
...  

Introduction. Regulation of drinking water quality is a very important area of health care and improving the quality of life of the population of the Russian Federation.The aim of this work is the development a model for the assessment of the drinking water quality and calculating the share of the population, including urban, provided with high-quality drinking water from centralized water supply systems, taking into account new methodological approaches to the evaluation of the quality of drinking water using the example of water supply to settlements in the Leningrad Region. Material and methods. The data on the organization of centralized cold water supply systems and monitoring systems for drinking water quality and the results of laboratory studies of drinking water quality in the cities of Volkhov, Svetogorsk, Slantsy, Tosno were studied. Statistical processing of the results was performed, the categories of quality of drinking water supplied to the population were determined, the number of the population provided with high-quality drinking water from the water supply system was calculated in accordance with Guidelines 2.1.4.0143-19.Results. In 2018, 100% of the population was provided with quality drinking water only in the city of Slantsy. In the city of Tosno, this index reached of 83.5%. In the cities of Volkhov and Svetogorsk, drinking water was rated as low-quality. But it is worth noting that in the cities of Volkhov and Slantsy laboratory tests were carried out at 2 points, in the city of Svetogorsk - only at the 1 point, which, given the number of residents, is not enough. For an objective assessment of the state of drinking water and the development of measures aimed at improving its quality, it is necessary to increase the number of monitoring points, as well as to include the results of control and supervision measures and production laboratory control conducted by water supply organizations in the volume of laboratory information.Conclusion. The proposed model allows us to assess the drinking water quality in centralized water supply systems and the proportion of the population, including urban, provided with quality drinking water at the level of the water supply system, settlement, municipal district (urban district), subject of the Russian Federation


2021 ◽  
Vol 5 (33) ◽  
pp. 77-85
Author(s):  
E. Matelyuk ◽  
◽  
D. Charny ◽  
O. Kovalenko ◽  
Yu. Onanko ◽  
...  

It is noted that the overwhelming majority of water supply systems operating in Ukraine are made of steel or cast iron, which are subject to corrosion. It has been established that/ one of the ways to reduce the corrosiveness of drinking water is the use of an orthopolyphosphate preparation “SeaQuest Liquid” (TU U 20.5-V 0502222-001:2017). The results of studies of the effect of the “SeaQuest Liquid” preparation on organoleptic and physicochemical indicators of drinking water are presented. It was determined that the treatment of tap drinking water with the “SeaQuest Liquid” preparation does not affect organoleptic indicators, the average levels of which practically did not undergo significant changes during 5 months of observation and were within the hygienic standards. In water samples, the levels of substances that make up the “SeaQuest Liquid” preparation (polyphosphates, orthophosphates) were within the normative values. The quality of water treated with the “SeaQuest Liquid” orthophosphate preparation, according to the main sanitary and chemical indicators, except for iron, meets the requirements of the hygienic standards DSanPiN 2.2.4.171-10. In some water samples, the iron content in water exceeded the hygienic standard (0.2 mg/dm3) and went beyond the maximum permissible level (1.0 mg/dm3). Under the action of “SeaQuest Liquid” in water treated with sodium hypochlorite, a decrease in the Langelier index was observed: from -2,23 to -2,08 and from -1,79 to -1,70, which indicates a decrease in its corrosivity. In water untreated with sodium hypochlorite under the influence of the “SeaQuest Liquid” preparation, a slight increase in the Langelier index was observed: from -1,80 to -1,95 and from -1,85 to -2,78, from -2,01 to -2,13, which indicates an increase in its corrosiveness. In the presence of sulphate-reducing and thiobacteria in water, the “SeaQuest Liquid” preparation increases the corrosion rate of steel by 2,9-7,2 times; subject to additional disinfection of water with sodium hypochlorite, it reduces this indicator by 1,4-2,7 times.


2018 ◽  
Vol 1 ◽  
pp. 9-13
Author(s):  
Usmanov I.A. ◽  
KHasanova M.I.

The following article describes the results of scientific research carried out during the period 2015-2017 years, which was devoted to assessing the efficiency of population’s centralized water supply systems, the quality of drinking water and predicting anthropogenic impact on the quality of the Chirchik and Akhangaran rivers’ water. It was realized that the level of supplying drinking water to population and the efficiency of water supply systems do not fully meet the requirements. The quality of drinking water and sources of water supply in some regions do not meet the standard requirements. As a result, the recommendations on modernization, increasing the efficiency of water supply systems and improving drinking water use conditions were developed in the Republic.


Author(s):  
VV Vasilyev ◽  
TV Ryabinina ◽  
MV Perekusihin ◽  
EV Vasilev

Introduction: Drinking water from centralized drinking water supply systems is not always safe due to its natural pollution with various chemicals and microbiological contamination occurring in the distribution system. In this regard, the role of the service exercising governmental water quality surveillance is growing. The purpose of the study was to assess the quality of drinking water and the associated health risk and to substantiate priority measures aimed at improving the quality of water in the centralized water supply systems of the region. Materials and methods: We examined the results of drinking water quality testing performed within the implementation of sanitary and epidemiological surveillance and socio-hygienic monitoring and incidence rates in morbidity of population in 27 districts of the Penza Region and the regional center for the years 2014–2019. Health risks from oral exposures to waterborne chemicals were assessed in accordance with Guidelines R 2.1.10.1920–04. The statistical relationship was studied by the correlation method. Results: We established that water quality in the centralized water supply systems fed by underground sources is determined by the chemical composition of the exploited aquifers that divide the territory of the Penza Region into four zones. The worst water quality was observed in the fourth zone where concentrations of natural iron, fluorides and boron in tap water were many times higher than their maximum permissible levels and the hazard quotient for fluorides exceeded the limit value (HQ = 2.845 for children and 1.219 for adults). In the third zone, iron posed the highest risks of diseases of mucosa and skin (HI = 0.296), the immune system (HI = 0.311), and hematopoietic system (H = 0.473) in children; we also established a strong correlation between the average annual concentration of iron in tap water and the incidence of genitourinary disorders, gastritis and duodenitis in the child population. Although the share of the population supplied with safe drinking water from centralized water supply systems increased from 86.5 % in 2014 to 89.4 % in 2019, the target set within the Regional Clean Water Project for 2019 was not achieved. Conclusion: The study results were taken into account when making additions to the Regional Clean Water Project in 2020 envisaging construction of iron removal plants and water well drilling in areas with low fluorine levels.


Georesursy ◽  
2014 ◽  
Vol 58 (3) ◽  
pp. 9-16 ◽  
Author(s):  
R.H. Musin ◽  
◽  
N.A. Kurlianov ◽  
Z.G. Fayzrahmanova ◽  
R.Z. Musina ◽  
...  

Medicina ◽  
2019 ◽  
Vol 55 (8) ◽  
pp. 492 ◽  
Author(s):  
Valciņa ◽  
Pūle ◽  
Mališevs ◽  
Trofimova ◽  
Makarova ◽  
...  

Background and Objectives: Legionella is one of the most important water-related pathogens. Inside the water supply systems and the biofilms, Legionella interact with other bacteria and free-living amoeba (FLA). Several amoebas may serve as hosts for bacteria in aquatic systems. This study aimed to investigate the co-occurrence of Legionella spp. and FLA in drinking water supply systems. Materials and Methods: A total of 268 water samples were collected from apartment buildings, hotels, and public buildings. Detection of Legionella spp. was performed in accordance with ISO 11731:2017 standard. Three different polymerase chain reaction (PCR) protocols were used to identify FLA. Results: Occurrence of Legionella varied from an average of 12.5% in cold water samples with the most frequent occurrence observed in hot water, in areas receiving untreated groundwater, where 54.0% of the samples were Legionella positive. The occurrence of FLA was significantly higher. On average, 77.2% of samples contained at least one genus of FLA and, depending on the type of sample, the occurrence of FLA could reach 95%. In the samples collected during the study, Legionella was always isolated along with FLA, no samples containing Legionella in the absence of FLA were observed. Conclusions: The data obtained in our study can help to focus on the extensive distribution, close interaction, and long-term persistence of Legionella and FLA. Lack of Legionella risk management plans and control procedures may promote further spread of Legionella in water supply systems. In addition, the high incidence of Legionella-related FLA suggests that traditional monitoring methods may not be sufficient for Legionella control.