scholarly journals Wind-Induced Dynamic Behavior of Mechanically Attached Single-Ply Membrane Roofing Systems Installed on Flat Roofs

2021 ◽  
pp. 1-23
Author(s):  
Yasushi Uematsu ◽  
Shingo Sugiyama ◽  
Takuto Usukura

The present paper investigates the wind-induced dynamic behavior of a mechanically attached single-ply membrane roofing system installed on flat roofs of middle-rise and high-rise buildings with or without parapets. First, the wind pressure distributions on the roof were measured in a turbulent boundary layer. The results indicate that the parapets affect the wind pressure distributions significantly. Very large peak suctions are induced near the windward corner of the roof in an oblique wind in the case of a building without parapets. Then, we have developed a test method for evaluating the wind-resistant performance of the roofing system using three Pressure Loading Actuators (PLAs) and a chamber to which a full-scale specimen is attached. In the experiments, the chamber was divided into three spaces by using thin silicon sheets. The PLAs generated different fluctuating pressures in these spaces using the time history of wind pressure coefficients measured at three points near the windward corner of the roof in an oblique wind. We measured the membrane deformations and the wind forces acting on the fasteners connecting the membrane with the structural substrate. The results indicate that horizontal forces nearly equal to or larger than the vertical ones are generated on the fasteners, which may cause pulling out of fasters more easily. The failure mode was found to be different from that obtained from a ramped pressure loading test. We have also developed a model of finite element analysis, which was validated by an experiment. The results of analysis for a wide area of roofing system indicate that relatively large horizontal forces may be generated on the fasteners in the field region of the roof for buildings with parapets.

Wind ◽  
2021 ◽  
Vol 1 (1) ◽  
pp. 44-62
Author(s):  
Yasushi Uematsu ◽  
Tetsuo Yambe ◽  
Tomoyuki Watanabe ◽  
Hirokazu Ikeda

The present paper proposes a measure for improving the wind-resistant performance of photovoltaic systems and mechanically attached single-ply membrane roofing systems installed on flat roofs by combining them together. Mechanically attached single-ply membrane roofing systems are often used in Japan. These roofing systems are often damaged by strong winds, because they are very sensitive to wind action. Recently, photovoltaic (PV) systems placed on flat roofs have become popular. They are also often damaged by strong winds directed onto the underside, which cause large wind forces onto the PV panels. For improving the wind resistance of these systems, we proposed to install PV panels horizontally with gaps between them. Such an installation may decrease the wind forces on the PV panels due to the pressure equalization effect as well as on the waterproofing membrane due to the shielding effect of the PV panels. This paper discusses the validity of such an idea. The pressure on the bottom surface of a PV panel, called the “layer pressure” here, was evaluated by a numerical simulation based on the unsteady Bernoulli equation. In the simulation, the time history of the external pressure coefficients, measured at many points on the roof in a wind tunnel, was employed. It was found that the wind forces, both on the PV panels and on the roofing system, were significantly reduced. The reduction was large near the roof’s corner, where large suction pressures were induced in oblique winds. Thus, the proposed method improved the wind resistance of both systems significantly.


1989 ◽  
Vol 17 (2) ◽  
pp. 86-99 ◽  
Author(s):  
I. Gardner ◽  
M. Theves

Abstract During a cornering maneuver by a vehicle, high forces are exerted on the tire's footprint and in the contact zone between the tire and the rim. To optimize the design of these components, a method is presented whereby the forces at the tire-rim interface and between the tire and roadway may be predicted using finite element analysis. The cornering tire is modeled quasi-statically using a nonlinear geometric approach, with a lateral force and a slip angle applied to the spindle of the wheel to simulate the cornering loads. These values were obtained experimentally from a force and moment machine. This procedure avoids the need for a costly dynamic analysis. Good agreement was obtained with experimental results for self-aligning torque, giving confidence in the results obtained in the tire footprint and at the rim. The model allows prediction of the geometry and of the pressure distributions in the footprint, since friction and slip effects in this area were considered. The model lends itself to further refinement for improved accuracy and additional applications.


2001 ◽  
Vol 29 (3) ◽  
pp. 134-154 ◽  
Author(s):  
J. R. Luchini ◽  
M. M. Motil ◽  
W. V. Mars

Abstract This paper discusses the measurement and modeling of tire rolling resistance for a group of radial medium truck tires. The tires were subjected to tread depth modifications by “buffing” the tread surface. The experimental work used the equilibrium test method of SAE J-1269. The finite element analysis (FEA) tire model for tire rolling resistance has been previously presented. The results of the testing showed changes in rolling resistance as a function of tread depth that were inconsistent between tires. Several observations were also inconsistent with published information and common knowledge. Several mechanisms were proposed to explain the results. Additional experiments and models were used to evaluate the mechanisms. Mechanisms that were examined included tire age, surface texture, and tire shape. An explanation based on buffed tread radius, and the resulting changes in footprint stresses, is proposed that explains the observed experimental changes in rolling resistance with tread depth.


2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Daisuke Takahashi ◽  
Yoshihiro Noyama ◽  
Tsuyoshi Asano ◽  
Tomohiro Shimizu ◽  
Tohru Irie ◽  
...  

Abstract Background Internal fixation is recommended for treating Vancouver B1 periprosthetic femoral fractures. Although several fixation procedures have been developed with high fixation stability and union rates, long-term weight-bearing constructs are still lacking. Therefore, the aim of the present study was to evaluate the stability of a double-plate procedure using reversed contralateral locking compression-distal femoral plates for fixation of Vancouver B1 periprosthetic femoral fractures under full weight-bearing. Methods Single- and double-plate fixation procedures for locking compression-distal femoral plates were analysed under an axial load of 1,500 N by finite element analysis and biomechanical loading tests. A vertical loading test was performed to the prosthetic head, and the displacements and strains were calculated based on load-displacement and load-strain curves generated by the static compression tests. Results The finite element analysis revealed that double-plate fixation significantly reduced stress concentration at the lateral plate place on the fracture site. Under full weight-bearing, the maximum von Mises stress in the lateral plate was 268 MPa. On the other hand, the maximum stress in the single-plating method occurred at the defect level of the femur with a maximum stress value of 1,303 MPa. The principal strains of single- and double-plate fixation were 0.63 % and 0.058 %, respectively. Consistently, in the axial loading test, the strain values at a 1,500 N loading of the single- and double-plate fixation methods were 1,274.60 ± 11.53 and 317.33 ± 8.03 (× 10− 6), respectively. Conclusions The present study suggests that dual-plate fixation with reversed locking compression-distal femoral plates may be an excellent treatment procedure for patients with Vancouver B1 fractures, allowing for full weight-bearing in the early postoperative period.


2013 ◽  
Vol 756-759 ◽  
pp. 4482-4486
Author(s):  
Chun Gan ◽  
Xue Song Luo

In recent years, frequent earthquakes have caused great casualties and economic losses in China. And in the earthquake, damage of buildings and the collapse is the main reason causing casualties. Therefore, in the design of constructional engineering, a seismicity of architectural structure is the pressing task at issue. Through time history analysis method, this paper analyzes the time history of building structural response and then it predicts the peak response of mode by response spectrum analysis. Based on this, this paper constructs a numerical simulation model for the architecture by using finite element analysis software SATWE. At the same time, this paper also calculates the structure seismic so as to determine the design of each function structure in architectural engineering design and then provides reference for the realization of earthquake-resistant building.


2010 ◽  
Vol 163-167 ◽  
pp. 2852-2856
Author(s):  
Chang Wu ◽  
Xiu Li Wang

In this study a kind of buckling-restrained braces (BRBs) as energy dissipation dampers is attempted for seismic performance of large span double-layer reticulated shell and the effectiveness of BRBs to protect structures against strong earthquakes is numerically studied. The hysteretic curve of such members is obtained through the simulation of the cyclic-loading test, and the equations of motion of the system under earthquake excitations are established. BRBs are then placed at certain locations on the example reticulated shell to replace some normal members, and the damping effect of the two installation schemes of BRBs is investigated by non-linear time-history analyses under various ground motions representing major earthquake events. Compared with the seismic behavior of the original structure without BRBs, satisfactory seismic performance is seen in the upgraded models, which clarifies the BRBs can reduce the vibration response of spatial reticulated structure effectively and the new system has wide space to develop double layer reticulated shell.


2007 ◽  
Vol 63 (1) ◽  
pp. 265-276 ◽  
Author(s):  
Yong YUAN ◽  
Hirokazu IEMURA ◽  
Akira IGARASHI ◽  
Tetsuhiko AOKI ◽  
Yoshihisa YAMAMOTO

2001 ◽  
Vol 36 (4) ◽  
pp. 373-390 ◽  
Author(s):  
S. J Hardy ◽  
M. K Pipelzadeh ◽  
A. R Gowhari-Anaraki

This paper discusses the behaviour of hollow tubes with axisymmetric internal projections subjected to combined axial and internal pressure loading. Predictions from an extensive elastic and elastic-plastic finite element analysis are presented for a typical geometry and a range of loading combinations, using a simplified bilinear elastic-perfectly plastic material model. The axial loading case, previously analysed, is extended to cover the additional effect of internal pressure. All the predicted stress and strain data are found to depend on the applied loading conditions. The results are normalized with respect to material properties and can therefore be applied to geometrically similar components made from other materials, which can be represented by the same material models.


1985 ◽  
Vol 22 (4) ◽  
pp. 592-599
Author(s):  
R. G. Horvath

A multiple loading testing method is suggested, which permits testing a single drilled pier foundation under three different conditions of load support. The pier may be tested under conditions of combined shaft and end-bearing resistance, end-bearing resistance only, and shaft resistance only. The advantages of this multiple loading test method include observation of the load-transfer and displacement behaviours of the pier under these three different support conditions and verification of the values obtained for the components of load support, i.e., shaft and end-bearing resistance, all from a single test pier.A special base load cell capable of performing a different function during each cycle of loading is required. A suitable load cell, consisting of a series of Freyssi flatjacks, and the method of operation are described.A multiple loading test procedure was used successfully as part of a field investigation program on full-scale pier sockets in weak shale. Data on the load-displacement behaviour of the pier tested using the multiple loading method are reported. Information concerning piers tested using conventional single loading methods are provided for comparison.The multiple loading test results were in good agreement with results obtained from conventional testing methods. Thus the multiple loading test method provides an economical means of obtaining a large amount of design information for drilled pier foundation systems, using a single test pier. Key words: field load test, multiple loading, drilled piers and caissons, shaft resistance, end-bearing resistance, combined shaft and end-bearing resistances, base load cell, shale.


Sign in / Sign up

Export Citation Format

Share Document