scholarly journals Development and performance analysis of a PCM based cooling fan for hot climate of Bangladesh

2020 ◽  
pp. 1-9
Author(s):  
Md. Anowar Hossain ◽  
I. M. Mahbubul ◽  
Md. Abdul Aziz ◽  
Hasan Mohammad Mostofa Afroz ◽  
Md. Rashedul Islam ◽  
...  

In hot climatic regions, some kind of cooling system is necessary to avoid warmth and humidity. Many of the available cooling systems are not economic and sustainable. In this study, sustainable and feasible space/room cooling systems have been experimentally analyzed. A solar operated cooling system with two options have been designed and their performances are compared. Phase Change Material (PCM) is proposed to store thermal energy instead of a costly battery. A 1200-watt compressor and fin-type condenser are used to construct the vapor compression system. When the incoming air is passed through the cooling coil, it gets cool. For this cooling coil, 50 feet copper tube is used. The front side copper tube diameter of the fan is 3/8 inch and the backside tube diameter is 1/2 inch. It took about 35 minutes and 5 minutes to minimize the room temperature at the desired level in the case of the stand fan and duct fan, respectively. Furthermore, the stand fan and duct fan systems reduced 3 ℃ and 6 ℃ of the outside temperature, respectively.

1984 ◽  
Vol 106 (2) ◽  
pp. 142-152 ◽  
Author(s):  
N. Lior ◽  
K. Koai

The subject of this analysis is a solar cooling system based on a novel hybrid steam Rankine cycle. Steam is generated by the use of solar energy collected at about 100° C, and it is then superheated to about 600° C in a fossil-fuel-fired superheater. The addition of about 20–26 percent of fuel doubles the power cycle’s efficiency as compared to organic Rankine cycles operating at similar collector temperatures. A comprehensive computer program was developed to analyze the operation and performance of the entire power/cooling system. Transient simulation was performed on an hourly basis over a cooling season in two representative climatic regions (Washington, D.C. and Phoenix, Ariz.). One of the conclusions is that the seasonal system COP is 0.82 for the design configuration and that the use of water-cooled condensers and flat-plate collectors of higher efficiency increases this value to 1.35.


2020 ◽  
Vol 142 (7) ◽  
Author(s):  
Hakan Caliskan ◽  
Dae-Young Lee ◽  
Hiki Hong

Abstract In this paper, the effects of regenerative evaporative coolers on the dry desiccant air cooling system are assessed. Thermodynamic analysis is performed point by point on the unmodified (ɛ = 0.67) and modified (ɛ = 1) regenerative evaporative cooler supported systems. It is found that the effectiveness and efficiency of the system were significantly increased by modification. Effectiveness of the system increases from 0.95 to 2.16 for the wet bulb and from 0.63 to 1.43 for dew point effectivenesses, while the exergy efficiency increases from 18.40% to 41.93%. Exergy and energy performances of the system increase 1.28 times and 0.61 times, respectively. Finally, sustainability is increased by 40% with the modification of the regenerative evaporative cooler. Also, changing the regenerative evaporative cooler of the solid desiccant wheel with the effective one can increase the overall system efficiency and performance without changing the sensible heat and desiccant wheels.


2011 ◽  
Vol 110-116 ◽  
pp. 2163-2169
Author(s):  
S. Khosravi ◽  
Yat Huang Yau ◽  
T.M.I. Mahlia ◽  
M.H. Saidi

In the recent researches HVAC with a based desiccant dehumidifier with a low ambient impact is more efficient in comparison to the traditional systems. Hybrid desiccant cooling systems can be used to control indoor air quality in buildings. This paper presents an integrated energy, entropy and exergy analysis of a hybrid desiccant cooling system compare to a compression system based on first and second laws of thermodynamic. The main objective is the use of a method called exergy costing applied to a conventional compression system that has been chosen to provide the proper conditioned air for a building in hot and humid condition. By applying the same method for the equivalent hybrid cooling system and finding the same exergy costing parameters, two systems can be in comparison to find the more economical system. The result illustrated hybrid desiccant cooling system can be providing 19.78% energy saving and 14.5% cheaper than the compression system the same capacity and lifetime. Nomenclature:


2018 ◽  
Vol 215 ◽  
pp. 01017
Author(s):  
Arfidian Rachman ◽  
Lisa Nesti

For areas with very hot and humid weather condition increased latent and sensible load are a major problem in cooling systems that will increase compressor work so that electricity consumption will also increase. Combined condenser with direct evaporate cooling will increase the heat removal process by using an evaporative cooler effect that will increase the efficiency of energy use. This paper presents the study of the use of evaporator cooling and condenser. This paper mainly calculated energy consumption in steam compression cooling systems and related problems. From the results of this study, the use of condensers with evaporative cooling, power consumption can be reduced to 46% and performance coefficient (COP) can be increased by about 12%, with 1,2 kW cooling capacity.


Electronics ◽  
2019 ◽  
Vol 8 (5) ◽  
pp. 582 ◽  
Author(s):  
Jae-Sub Ko ◽  
Jun-Ho Huh ◽  
Jong-Chan Kim

This paper proposes a control method to improve the energy efficiency and performance of cooling fans used for cooling. In Industry 4.0, a large number of digital data are used, and a large number of data centers are created to handle these data. These data centers consist of information technology (IT) equipment, power systems, and cooling systems. The cooling system is essential to prevent failure and malfunction of the IT equipment, which consumes a considerable amount of energy. This paper proposes a method to reduce the energy used in such cooling systems and to improve the temperature control performance. This paper proposes an fuzzy proportional integral(FPI) controller that controls the input value of the proportional integral(PI) controller by the fuzzy controller according to the operation state, a VFPI (Variable Fuzzy Proportional Integral) controller that adjusts the gain value of the fuzzy controller, and a variable fuzzy proportion integration-variable limit (VFPI-VL) controller that adjusts the limit value of the fuzzy controller’s output value. These controllers control the fan applied to the cooling system and compare the energy consumed and temperature control performance. When the PI controller consumes 100% of the power consumed, the FPI is 50.5%, the VFPI controller is 44.3%, and the VFPI-VL is 32.6%. The power consumption is greatly reduced. In addition, the VFPI-VL controller is the lowest in temperature variation, which improves the energy efficiency and performance of the cooling system using a fan. The methods presented in this paper can not only be applied to fans for cooling, but also to variable speed systems for various purposes and improvement of performance and efficiency can be expected.


1983 ◽  
Vol 105 (2) ◽  
pp. 217-223
Author(s):  
M. L. Warren ◽  
M. Wahlig

Economic and thermal performance analyses of typical residential and commercial active solar cooling systems are used to determine cost goals for systems to be installed between the years 1986 and 2000. Market penetration for heating, ventilating, and air conditioning systems depends on payback period, which is related to the expected real return on investment. Postulating a market share for solar cooling systems increasing to 20 percent by the year 2000, payback and return on onvestment goals as a function of year of purchase are established. The incremental solar system cost goal must be equal to or less than the 20-year present value of future energy savings, based on thermal performance analysis, at the desired return on investment. Methods for achieving these cost goals and expected solar cooling system costs will be discussed.


2019 ◽  
Vol 11 (21) ◽  
pp. 91-101
Author(s):  
Falah A-H. Mutlak

The systems cooling hybrid solar uses solar collector to convert solar energy into the source of heat for roasting Refrigerant outside of the compressor and this process helps in the transformation of Refrigerant from the gas to a liquid state in two-thirds the top of the condenser instead of two-thirds the bottom of the condenser as in Conventional cooling systems and this in turn reduces the energy necessary to lead the process of cooling. The system cooling hybrid use with a capacity of 1 ton and Refrigerant type R22 and the value of current drawn by the system limits (3.9-4.2A), the same value of electric current calculated by the system are  Conventional  within this atmosphere of Iraq, and after taking different readings of the temperatures and pressure to several points in the system's found that the Refrigerant when it comes out of the compressor, it loses part of the temperature of the water in the solar collector through a heat exchanger while the literature published in accordance with the manufacturers that the solar collector, a kind of vacuum tubes contributes to raise the pressure and temperature of the fluid cooler to reduce the consumption of energy spent on compressor. Therefore, the system described by the current not fit for domestic use within the Iraqi environmental conditions.


2020 ◽  
pp. 75-86
Author(s):  
Sergio Antonio Camargo ◽  
Lauro Correa Romeiro ◽  
Carlos Alberto Mendes Moraes

The present article aimed to test changes in cooling water temperatures of males, present in aluminum injection molds, to reduce failures due to thermal fatigue. In order to carry out this work, cooling systems were studied, including their geometries, thermal gradients and the expected theoretical durability in relation to fatigue failure. The cooling system tests were developed with the aid of simulations in the ANSYS software and with fatigue calculations, using the method of Goodman. The study of the cooling system included its geometries, flow and temperature of this fluid. The results pointed to a significant increase in fatigue life of the mold component for the thermal conditions that were proposed, with a significant increase in the number of cycles, to happen failures due to thermal fatigue.


Author(s):  
A. Al Bassam ◽  
Y. M. Al Said

This paper summarizes the experiences with the first gas turbine inlet air cooling project in Saudi Arabia. It will cover the feasibility study, cooling system options, overview, system equipment description, process flow diagram, construction, commissioning, start-up and performance of the project which is currently under commissioning and initial start up at Qassim Central Power Plant (QCPP) owned by Saudi Electric Company (S.E.C.) Central Region Branch.


Sign in / Sign up

Export Citation Format

Share Document