scholarly journals circPhc3 sponging microRNA‑93‑3p is involved in the regulation of chondrocyte function by mechanical instability in osteoarthritis

2021 ◽  
Vol 49 (1) ◽  
Author(s):  
Zhiyuan Wang ◽  
Zhitao Rao ◽  
Xin Wang ◽  
Chao Jiang ◽  
Yi Yang
2020 ◽  
Vol 10 (8) ◽  
pp. 2790
Author(s):  
Wenzheng Zhuang ◽  
Chao Yang ◽  
Zhigang Wu

Hybrid corrugated sandwich (HCS) plates have become a promising candidate for novel thermal protection systems (TPS) due to their multi-functionality of load bearing and thermal protection. For hypersonic vehicles, the novel TPS that performs some structural functions is a potential method of saving weight, which is significant in reducing expensive design/manufacture cost. Considering the novel TPS exposed to severe thermal and aerodynamic environments, the mechanical stability of the HCS plates under fluid-structure-thermal coupling is crucial for preliminary design of the TPS. In this paper, an innovative layerwise finite element model of the HCS plates is presented, and coupled fluid-structure-thermal analysis is performed with a parameter study. The proposed method is validated to be accurate and efficient against commercial software simulation. Results have shown that the mechanical instability of the HCS plates can be induced by fluid-structure coupling and further accelerated by thermal effect. The influences of geometric parameters on thermal buckling and dynamic stability present opposite tendencies, indicating a tradeoff is required for the TPS design. The present analytical model and numerical results provide design guidance in the practical application of the novel TPS.


2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Markus Wenning ◽  
Dominic Gehring ◽  
Thomas Lange ◽  
David Fuerst-Meroth ◽  
Paul Streicher ◽  
...  

Abstract Background Chronic ankle instability (CAI) arises from the two etiological factors of functional (FAI) and mechanical ankle instability (MAI). To distinguish the contributions of the two etiologies, it is necessary to quantitively assess functional and mechanical deficits. Validated and reproducible assessment of mechanical instability remains a challenge in current research and practice. Physical examination, stress sonography and a novel 3D stress MRI have been used, while stress radiography has been called into question and arthrometry is limited to research purposes. The interaction of these primarily mechanical measurements with the functional and subjective components of CAI are subject to debate. The aim of this study was the evaluation of the clinical and biomechanical preferences of the three different methods in the diagnosis of MAI. Methods In this cross-sectional diagnostic study, we compared three different diagnostic approaches to mechanical ankle instability: (1) manual stress testing (anterior drawer test [ADT] and talar tilt test [TTT]), (2) stress sonography and (3) 3D stress MRI (3SAM) The latter includes quantification of 3D cartilage contact area (CCA) in plantarflexion-supination compared to neutral-null position. We applied these measurements to a cohort of patients suffering from chronic mechanical ankle instability (n = 25) to a matched cohort of healthy controls (n = 25). Perceived instability was assessed using the Cumberland Ankle Instability Tool (CAIT) and Forgotten Joint Score (FJS). Functional deficits were measured using postural sway and the y-Balance test. Results Significant differences between the two groups (single-factor “group” ANOVA, p < 0.05) were found in all of the mechanical assessments with strong effect sizes. Spearman’s correlations were strong for CAIT and manual stress testing (TTT rho = − 0.83, ADT rho = − 0.81), 3D stress MRI (rho = − 0.53) and stress sonography (TTT rho = − 0.48, ADT rho = − 0.44). Furthermore, the correlation between manual stress testing and CCA in the fibulotalar articulation (CCAFT) was strong (rho = 0.54) and the correlations to stress sonography were moderate (ADT rho = 0.47 and TTT rho = 0.43). The calculation of cutoff values revealed a distance of > 5.4 mm increase in ligament length during stress sonography (sensitivity 0.92, specificity 0.6) and > 43% loss of articulating surface in the fibulotalar joint (CCAFT in supination-plantarflexion using 3SAM, sensitivity 0.71, specificity 0.8) as potential cutoff values for diagnosing MAI. Conclusions Manual stress testing showed to be a valuable method of identifying mechanical ankle instability. However, due to is subjective character it may overvalue patient-reported instability as a factor which explains the high correlation to the CAIT-score, but this may also reduce its value in diagnosing the isolated mechanical quality of the joint. Thus, there is a persisting need for objective and reproducible alternatives focusing on MAI. According to our results, 3D stress MRI and stress sonography represent valuable alternatives and may be used to quantitively assess mechanical ankle instability in research and practice. Trial registration German Registry of Clinical Trials # DRKS00016356, registered on 05/11/2019.


2020 ◽  
Vol 7 (Supplement_1) ◽  
pp. i45-i53
Author(s):  
Rupesh Kotecha ◽  
Nicolas Dea ◽  
Jay S Detsky ◽  
Arjun Sahgal

Abstract With the growing incidence of new cases and the increasing prevalence of patients living longer with spine metastasis, a methodological approach to the management of patients with recurrent or progressive disease is increasing in relevance and importance in clinical practice. As a result, disease management has evolved in these patients using advanced surgical and radiotherapy technologies. Five key goals in the management of patients with spine metastases include providing pain relief, controlling metastatic disease at the treated site, improving neurologic deficits, maintaining or improving functional status, and minimizing further mechanical instability. The focus of this review is on advanced reirradiation techniques, given that the majority of patients will be treated with upfront conventional radiotherapy and further treatment on progression is often limited by the cumulative tolerance of nearby organs at risk. This review will also discuss novel surgical approaches such as separation surgery, minimally invasive percutaneous instrumentation, and laser interstitial thermal therapy, which is increasingly being coupled with spine reirradiation to maximize outcomes in this patient population. Lastly, given the complexities of managing recurrent spinal disease, this review emphasizes the importance of multidisciplinary care from neurosurgery, radiation oncology, medical oncology, neuro-oncology, rehabilitation medicine, and palliative care.


2021 ◽  
Vol 29 (1) ◽  
pp. 230949902098457
Author(s):  
Chengjie Yuan ◽  
Genrui Zhu ◽  
Zhifeng Wang ◽  
Chen Wang ◽  
Xu Wang ◽  
...  

Purpose: This study aimed to use MRI to evaluate the fibula and talus position difference in functional and mechanical ankle stability patients. Methods: 61 and 68 patients with functional and mechanical instability, and 60 healthy volunteers were involved. Based on the axial MRI images, the rotation of the talus was identified through the Malleolar Talus Index (MTI). The position relative to the talus (Axial Malleolar Index, AMI) and medial malleolus (Intermalleolar Index, IMI) were used to evaluated the displacement of the fibula. Results: Post hoc analysis showed that the values of malleolar talus index was significantly larger among mechanical instability (89.18° ± 2.31°) than that in functional instability patients (86.55° ±61.65°, P < 0.001) and healthy volunteers (85.59° ± 2.42°, P < 0.001). The axial malleolar index of the mechanical instability patients (11.39° ± 1.41°) were significantly larger than healthy volunteers (7.91° ± 0.83°) (P < 0.0001). There were no statistically significant differences in the above three indexes between the functional instability patients and healthy volunteers. Conclusion: The functional instability patients didn’t have a posteriorly positioned fibula and an internally rotated talus. The malleolar talus index was significantly larger among mechanical instability patients than that in functional instability patients. Increased malleolar talus index may become a new indirect MRI sign for identifying functional and mechanical instability patients.


Author(s):  
Arjun Krishnan ◽  
Ashwin Krishnan ◽  
Mark Costello

This article examines the fundamental aspects of controlling ground resonance in rotorcraft equipped with actively controlled landing gear. Ground resonance is a mechanical instability affecting rotorcraft on the ground. It occurs at certain rotor speeds, where the lead–lag motion of the rotor couples with the motion of fuselage creating a self-excited oscillation. Typically, passive or semi-active lag dampers are used to avoid instability; however, these are undesirable from a design and maintenance perspective. Innovations in active landing gear for rotorcraft, such as articulated robotic legs, have provided an alternate approach to avoid the instability, eliminating the need for lag dampers with respect to ground resonance. This article extends classic ground resonance to include movable landing gear and identifies key physical parameters affecting dynamic behavior. Applying LQ optimal control to this model, it is shown that ground resonance instability can be eliminated using active landing gear as the control mechanism, even when there is no lag damping present in the rotor. In addition, while superior performance is achieved when landing gear movement can occur both longitudinally and laterally, it is still possible to stabilize ground resonance with inputs in a single direction, albeit with reduced performance.


2014 ◽  
Vol 112 (9) ◽  
Author(s):  
Sung Hoon Kang ◽  
Sicong Shan ◽  
Andrej Košmrlj ◽  
Wim L. Noorduin ◽  
Samuel Shian ◽  
...  

Author(s):  
S.J Garcia-Vergara ◽  
L Iglesias-Rubianes ◽  
C.E Blanco-Pinzon ◽  
P Skeldon ◽  
G.E Thompson ◽  
...  

This paper examines the mechanism of pore formation in anodic films on aluminium. For this purpose, the dimensional changes of specimens during growth of porous films on aluminium in phosphoric and sulphuric acid electrolytes are examined using transmission and scanning electron microscopies. Further, the compositions of films and the efficiencies of anodizing are determined by Rutherford backscattering spectroscopy and nuclear reaction analysis. Significantly, the efficiency of anodizing is about 60%, while the surface of the anodic film is located above the original aluminium surface, i.e. before anodizing. The ratio of the thickness of the anodic film relative to the thickness of the consumed aluminium is about 1.35 for the selected conditions of anodizing. The behaviour runs counter to the widely accepted mechanism of pore formation by field-assisted dissolution of alumina. It is explained by the high plasticity of the anodic alumina in the barrier region in the presence of ionic transport, with film growth stresses displacing material from the barrier layer towards the cell wall region during anodizing. The response of the film to volume constraints on growth indicates a major role of stress and stress-relief processes in determining the morphology and self-regulating organization of pores.


2008 ◽  
Vol 19 (41) ◽  
pp. 415708 ◽  
Author(s):  
M Riaz ◽  
A Fulati ◽  
Q X Zhao ◽  
O Nur ◽  
M Willander ◽  
...  

1996 ◽  
Vol 118 (3) ◽  
pp. 527-531 ◽  
Author(s):  
L. Rapoport

Seizure phenomena in pin-on-disk tests have been studied for “soft” and “hard” steel specimens. Differences in competing and dominant wear mechanisms under steady state friction have been preserved for “soft” and “hard” specimens in the region of transition to seizure or galling. Severe wear was observed for “soft” specimens under all loads tested, while adhesion and splitting off of wear particle conglomerates (microseizure) were identified for “hard” specimens. The contact temperature, calculated in accordance with the temperature model of plastically deformed contact spots (Kuhlmann-Wilsdorf), has appeared to be low for “soft” specimens and not sufficient for adhesion interaction. The effect of oxide films on the friction of “hard” specimens has been estimated in accordance with the temperature model for a coated semi-infinite body (Tian and Kennedy). The insulated oxide films on the surface of “hard” specimens create the “skin effect” and lead, therefore, to raising the temperature up to the temperature of adhesion interaction. Temperature instability of hard surfaces has been demonstrated to result from the “skin effect” and from a disturbance in equilibrium of formation and failure of oxide films. It has been shown that for “soft” specimens the prime cause of transition to seizure was the mechanical interlocking between the wear particles and the soft disk surface combined with mechanical instability, while for “hard” specimens the cause was temperature instability. A more realistic temperature model of the contact has been considered, which takes into account some competing wear mechanisms (oxidational wear, ploughing, delamination) and the effect of wear particles.


Sign in / Sign up

Export Citation Format

Share Document