Web-Based Heating Boiler Control System Research

2012 ◽  
Vol 198-199 ◽  
pp. 1774-1778
Author(s):  
Dong Song Luo ◽  
Ji Ying Tuo

Aiming at the defects of traditional heating boiler control systems, in Geographical limitations, waste of human resources etc. We combines Web technology with traditional heating boiler control strategies, developed a B/S,C/S mixed-mode control system, that allows workers look up data and control heating boilers from Website safely, no matter where the heating boiler located. Website is developed in ASP.NET, other programs are developed in VC++.NET. This system can improve management and production efficiencies, reduce human resources and operating costs.

2010 ◽  
Vol 130 (12) ◽  
pp. 2276-2285
Author(s):  
Shintaro Yanagihara ◽  
Akira Ishihara ◽  
Toshinao Ishii ◽  
Junichi Kitsuki ◽  
Kazuo Seo

2022 ◽  
Vol 166 ◽  
pp. 108812
Author(s):  
Vinay Kumar ◽  
Kailash Chandra Mishra ◽  
Pooja Singh ◽  
Aditya Narayan Hati ◽  
Mohan Rao Mamdikar ◽  
...  

1990 ◽  
Vol 112 (3) ◽  
pp. 365-371 ◽  
Author(s):  
Y. Halevi ◽  
A. Ray

This paper presents statistical analysis of delays in Integrated Communication and Control System (ICCS) networks [1–4] that are based on asynchronous time-division multiplexing. The models are obtained in closed form for analyzing control systems with randomly varying delays. The results of this research are applicable to ICCS design for complex dynamical processes like advanced aircraft and spacecraft, autonomous manufacturing plants, and chemical and processing plants.


Author(s):  
Itsuki Naito ◽  
Taisuke Koyamada ◽  
Keisuke Yamamoto ◽  
Kingo Igarashi ◽  
Hideo Harada ◽  
...  

This paper introduces the Instrumentation and Control (I&C) system for the proposed UK Advanced Boiling Water Reactor (UK ABWR) offered by Hitachi-GE Nuclear Energy, Ltd (Hitachi-GE). Hitachi-GE has been progressing the UK Generic Design Assessment (GDA) licensing process over the last 3 years. This is the process through which the Office for Nuclear Regulations (ONR) assesses the UK ABWR for suitability from a nuclear safety, security, environmental protection and waste management perspective and it is the first step towards proceeding with the construction phase in the UK. ONR’s regulatory expectations setting out relevant good practice are described in the Safety Assessment principles (SAPs), which are considered into the I&C design for UK ABWR. In addition, it has also been designed to take into account relevant good practices and regulations. In accordance with expectations derived from SAPs, the UK ABWR I&C systems are categorized and classified as required by IEC 61513 and IEC 61226. In addition, the overall I&C architecture, including all associated Human-Machine Interfaces (HMIs), abides by the principles independence and diversity of safety measures, segregation and separation of the protection and control systems. As a result, the UK ABWR I&C architecture is composed of major eight sub-systems. The eight sub-systems are: -Safety System Logic and Control system (SSLC) -Hardwired Backup System (HWBS) -Safety Auxiliary Control System (SACS) -Plant Control System (PCntlS) -Reactor/Turbine Auxiliary Control System (RTACS) -Plant Computer System (PCS) -Severe Accident Control and Instrumentation system (SA C&I) -Other dedicated C&I systems. The features for each sub-system such as redundancy of safety train or segregation among divisions are specified so that each sub-system will achieve its reliability as well as increase availability. While in the Japanese ABWR safety I&C system, the main protection system (SSLC), is microprocessor-based from the decades of successful operating experience in the past BWR, to meet the UK regulatory regime expectation on diversity between Class 1 platform and non-Class 1 platform, the SSLC (Class 1) for the UK ABWR is by Field Programmable Gate Array (FPGA). This system is currently under development and complies with IEC 62556. Its safety integrity level is planned to be SIL 3 (as a single division) and SIL 4 (as a four division system) as defined in IEC 61508. The HMIs which constitute an integral part of the I&C systems are also designed to comply with the I&C architecture regarding their categorization and classification with consideration of Human Factors (HF) modern methods taken into accounts.


Aviation ◽  
2010 ◽  
Vol 14 (3) ◽  
pp. 77-82 ◽  
Author(s):  
Grzegorz Kopecki ◽  
Jacek Pieniążek ◽  
Tomasz Rogalski ◽  
Pawel Rzucidło ◽  
Andrzej Tomczyk

The article presents the project of UAV control system realized at Department of Avionics and Control Systems of Rzeszów University of Technology. The project is based on earlier experiences. In the article general structure of the onboard control system is shown as well as the structure of control station. There are described in proposed control and navigation procedures as well as human factor, failure detection and system reconfiguration. Santrauka Šiame straipsnyje aprašomas bepiločiu orlaiviu kontroles sistemos projekto lgyvendinimas Ržešovo technologijos universiteto Aviadjos prietaisu ir kontroles sistemu katedroje. Projektas atliktas remiantis ankstesne patirtimi. Pateikta ne tik borto sistemu bendroji struktūra, bet ir kontroles stočiu struktūra. Darbe nagrinejamas žmogaus veiksnys, gedimu aptikimas ir sistemu rekonfigūravimas pasiūlytose kontroles ir navigacijos procedūrose.


Author(s):  
Lee A. Cysouw ◽  
Douglas C. Osburn ◽  
Nader M. Rabadi

Remote communications to field devices for data monitoring and controls has greatly reduced operating costs, reduced downtime, and helped to optimize our industry. With the ever growing threat of cyber-attacks, the need for securing that data is becoming a more common topic of discussion. Whether collecting SCADA or Measurement data from the field, doing remote configuration, or even sitting dormant, it is important to keep the line of communication to your devices secure. This presentation will discuss potential threats and examples of cyber-attacks. It will cover industry standards, types of cyber security, and the importance and best practices for securing data for Measurement and/or SCADA and control systems.


Sign in / Sign up

Export Citation Format

Share Document