This paper investigates the compressive strength and splitting tensile strength of ultra high strength concrete containing steel fiber. The steel fibers were added at the volume fractions of 0%, 0.5%, 0.75%, 1.0% and 1.5%. The compressive strength of the steel fiber reinforced ultra high strength concrete (SFRC) reached a maximum at 0.75% volume fraction, being a 15.5% improvement over the UHSC. The splitting tensile strength of the SFRC improved with increasing the volume fraction, achieving 91.9% improvements at 1.5% volume fraction. Strength models were established to predict the compressive and splitting tensile strengths of the SFRC. The models give predictions matching the measurements. Conclusions can be drawn that the marked brittleness with low tensile strength and strain capacities of ultra high strength concrete (UHSC) can be overcome by the addition of steel fibers.

2010 ◽  
Vol 150-151 ◽  
pp. 996-999
Author(s):  
Chang Wang Yan ◽  
Jin Qing Jia ◽  
Ju Zhang ◽  
Rui Jiang

The marked brittleness with low tensile strength and strain capacities of ultra high strength concrete (UHSC) with compressive strength of 100 MPa can be overcome by the addition of polyvinyl alcohol (PVA) fibers. The compressive strength and splitting tensile strength of ultra high strength concrete containing PVA fibers are investigated this paper. The PVA fibers were added at the volume fractions of 0%, 0.17%, 0.25%, 0.34% and 0.5%. The compressive strength of the PVA fiber reinforced ultra high strength concrete (PFRC) reached a maximum at 0.5% volume fraction, being an 8.2% improvement over the UHSC. The splitting tensile strength of the PFRC improved with increasing the volume fraction, achieving 46.7% improvements at 0.5% volume fraction. The splitting strength models were established to predict the compressive and splitting tensile strengths of the PFRC. The models give predictions matching the measurements.


Materials ◽  
2021 ◽  
Vol 15 (1) ◽  
pp. 135
Author(s):  
Shanming Qin ◽  
Danying Gao ◽  
Zhanqiao Wang ◽  
Haitang Zhu

The behavior of steel fiber concrete, which is the most widely used building material, has been widely examined. However, methods for calculating Fracture parameters differ by fracture behavior of SFHSC with different strengths. In this study, the fracture behavior of steel-fiber-reinforced high-strength concrete (SFHSC) was -investigated using three-point bending tests. A total of 144 notched concrete beams with a size of 100 mm × 100 mm × 515 mm were tested for three-point bending in 26 groups. The effects of the steel fiber volume ratio, steel fiber type, and relative notch depth on the fracture toughness (KIC) and fracture energy (GF) of SFHSC specimens were studied. The results show that an increase in the volume fraction of steel fiber (ρf) added to high-strength concrete (HSC) significantly improves the fracture behavior of HSC. As compared to milled and sheared corrugated steel fibers, cut bow steel fibers significantly improve the fracture behavior of SFHSC. The effect of incision depth changes on the KIC and GF of SFHSC and HSC for the comparison group has no common characteristics. With an increase in incision depth, the values of KIC of the SFHSC specimens decrease slightly. The GF0.5/GF0.4 of the SFHSC specimens show a decreasing trend with an increase in ρf. According to the test results, we propose calculation models for the fracture behavior of SFHSC with different strengths. Thus, we present a convenient and accurate method to calculate fracture parameters, which lays a foundation for subsequent research.


2019 ◽  
Vol 9 (2) ◽  
pp. 202-207
Author(s):  
Imad R. Mustafa ◽  
Omar Q. Aziz

An experimental program is carried out to evaluate the mix design and mechanical properties of normal strength concrete (NSC) grade 40 MPa and high-strength concrete grade 60 and 80 MPa. The study investigates using silica fume to produce high-strength concrete grade 80 MPa and highlights the influence of adding steel fiber on the mechanical properties of normal and high-strength concrete. For NSC, the compressive strength is found at 7 and 28 days. While for higher strength concrete, the compressive strength is determined at 7, 28, and 56 days. The splitting tensile strength and flexural strength is determined at 28 days. Based on results, the specimens with 14% silica fume are higher compressive strength than the specimens with 10% silica fume by 21.8%. The presence of steel fiber increased the compressive strength of normal and high-strength concrete at 7, 28, and 56 days curing ages with different percentage and the steel fiber has an important role in increasing the splitting tensile strength and flexural strength of normal and high-strength concrete.


2012 ◽  
Vol 476-478 ◽  
pp. 1568-1571
Author(s):  
Ting Yi Zhang ◽  
Guang He Zheng ◽  
Ping Wang ◽  
Kai Zhang ◽  
Huai Sen Cai

Through the three-point bending test on the specimens of steel fiber reinforced high strength concrete (SFHSC), the effects of influencing factors including water-cement ratio (W/C) and the fiber volume fraction (ρf) upon the critical value(JC) of J integral were studied. The results show that the variation tendencies of JC are different under different factors. JC meets the linear statistical relation with W/C, ρf, respectively.


2010 ◽  
Vol 168-170 ◽  
pp. 2230-2234
Author(s):  
Ting Yi Zhang ◽  
Zi Li Wang ◽  
Dan Ying Gao

Through the three-point bending test on the specimens of steel fiber reinforced high strength concrete (SFHSC) and plain high strength concrete (HSC) with the size of 100 mm×100 mm×515 mm, the effects of influencing factors including the fiber volume fraction (ρf) and relative notch depth (a/W) upon the fracture energy and the work of applied force (gravity and external force) were studied. The results show that the effect of ρf upon the fracture energy is more obvious; the variation tendencies for the increment ratio of the fracture energy and that of the work of applied force are different under different factors; the fracture energy is dependent on the work of external force. Based on the test results, the formula was established for calculating the fracture energy.


Fibers ◽  
2019 ◽  
Vol 7 (10) ◽  
pp. 93 ◽  
Author(s):  
Yun ◽  
Lim ◽  
Choi

: This paper investigates the effects of the tensile strength of steel fiber on the mechanical properties of steel fiber-reinforced high-strength concrete. Two levels of steel fiber tensile strength (1100 MPa and 1600 MPa) and two steel fiber contents (0.38% and 0.75%) were used to test the compression, flexure, and direct shear performance of steel fiber-reinforced high-strength concrete specimens. The aspect ratio for the steel fiber was fixed at 80 and the design compressive strength of neat concrete was set at 70 MPa to match that of high-strength concrete. The performance of the steel fiber-reinforced concrete that contained high-strength steel fiber was superior to that which contained normal-strength steel fiber. In terms of flexural performance in particular, the tensile strength of steel fiber can better indicate performance than the steel fiber mixing ratio. In addition, a compression prediction model is proposed to evaluate compression toughness, and the model results are compared. The predictive model can anticipate the behavior after the maximum load.


2021 ◽  
Vol 45 (4) ◽  
pp. 351-359
Author(s):  
Noor Alhuda Sami Aljabbri ◽  
Mohammed Noori Hussein ◽  
Ali Abdulmohsin Khamees

Fire or high temperature is a serious issue to ultra-high-strength concrete (UHSC). Strength reduction of UHPCs may amount to as high as 80 percent after exposure to 800℃. A sum of four UHSC mixes was synthesized and evaluated in this study after getting exposed to extreme temperatures that reach 1000°C. Steel and polypropylene (PP) fibers were used in this experiment. A total of four mixes were made of UHSC without fibres as a control mix (UHSC-0), UHSC with 2% steel fibres (UHSC-S), UHSC with 2% PP fibres (UHSC-P) and UHSC with 1% steel fibres + 1% PP fibres (UHSC-SP). Workability, direct tensile strength, compressive strength, and splitting tensile strength were examined. Particularly, emphasis was devoted to explosive spalling since UHPCs are typically of compact structure and hence more prone to explosive spalling than other concretes. It was determined that the mixture UHSC-SP had high fire resistance. Following exposure to 1000℃, this mixture preserved a residual compressive strength of 36 MPa, splitting tensile strength of 1.62 MPa and direct tensile strength of 0.8 MPa. On the other hand, UHSC-P also had good fire resistance while UHSC-0 and UHSC-S experienced explosive spalling after heating above 200ᴼC. The incorporation of steel fibers in UHSC-S and UHSC-SP mixtures reveals higher tensile and compressive strength findings at different elevated temperatures as compared to UHSC-0 and UHSC-P. In addition, the result of direct tensile strength appears to be lower than splitting tensile strength at different raised temperatures.


2010 ◽  
Vol 163-167 ◽  
pp. 1586-1591
Author(s):  
Jie Lei ◽  
Dan Ying Gao ◽  
Hua Fan

Based on the experiments of 10 model specimens of fiber reinforced high strength concrete three-pile caps with the dimension of 831mm×831mm×831mm, the mechanical behavior and the important factors on the cracking load and ultimate bearing capacity of fiber reinforced high strength concrete three-pile caps were researched. The study indicates that with increasing of concrete strength, the volume fraction of steel fiber, the effective thickness and reinforcement ratio of pile cap, the bearing capacity of three-pile caps improves largely. At the same time the type of steel fiber and steel ratio have remarkable effects on the bearing capacity. The results are valuable for establishing bearing capacity calculation formulas of fiber reinforced high strength concrete three-pile caps and improving “the Technical Specification for fiber Reinforced Concrete Structure.”