Experimental Study on Mechanical Properties of Axially Loaded PVC Tubed Short Concrete Columns

2011 ◽  
Vol 99-100 ◽  
pp. 715-718 ◽  
Author(s):  
Jun Dong ◽  
De Ping Chen ◽  
Ju Mei Zhao ◽  
De Shan Shan ◽  
Xin Yue Liu ◽  
...  

Twelve PVC tubed short concrete columns and four columns without PVC tube confined were tested under axial load to investigate mechanical properties of axially loaded PVC tubed short concrete columns . The principal influencing factors such as concrete strength, loading condition and ratio of height to diameter were studied. Test results indicated that strength and deformation performance of core concrete increased as a result of the confinement of PVC tube. The PVC tube confinement effect on concrete will decrease with an increase in strength of concrete. Load- carrying capacity and deformation of short composite columns with different loading condition made some difference. As the ratio of height to diameter increases, load- carrying capacity and plasticity of short composite columns decreased gradually.

2019 ◽  
Vol 25 (10) ◽  
pp. 88-107
Author(s):  
Omar Shamal Farhan

Nowadays, the use of recycled waste construction materials instead of aggregates is becoming popular in construction owing to its environmental benefits. This paper presents an experimental and analytical campaign to study the behavior of axially loaded columns constructed from recycled aggregates. The latter was used instead of natural aggregates, and they were collected from the waste of previous concrete constructions. Different concrete mixtures made from varying amounts of recycled aggregates ranged from 0 to 50% of the total coarse aggregate were conducted to achieve 28 MPa. The effect of steel fibers is another investigated variable with volumes ranged from 0 to 2% concerning concrete’s mixture. The experimental results showed that the concrete strength is dependent on the amount of recycled aggregates. When the recycled aggregates were less than 30% of the total aggregates, they had a negligible effect on concrete strength and the load carrying capacity of the column models were improved. Also, the presence of steel fibers enhanced the load carrying capacity of the columns constructed from concrete with recycled aggregates of more than 30%. Finite element analysis (using ANSYS 16.1 software program) was conducted to simulate the experimental investigations, and they achieved good agreements with the test results.


BioResources ◽  
2019 ◽  
Vol 14 (4) ◽  
pp. 8640-8655
Author(s):  
Eliška Máchová ◽  
Nadežda Langová ◽  
Roman Réh ◽  
Pavol Joščák ◽  
Ľuboš Krišťák ◽  
...  

The effect of moisture content on mechanical properties of corner furniture joints was evaluated for when different joining methods and materials were used. Results included statistical processing of the measured and calculated data and evaluation of the effect of selected factors on mechanical properties of joints caused by using mechanical fasteners and glue. The load-carrying capacity and stiffness of corner joints were investigated in two environments, humid and dry, with standard conditions for temperature and pressure, i.e., dry environment had a temperature of 23 °C ± 2 °C and relative humidity of 45% ± 5%, and the humid environment had a temperature of 23 °C ± 2 °C and relative humidity of 90% ± 5%. The two types of materials used were particleboard (PB) with a thickness of 12 mm and artificial stone (plastic) with a thickness of 12 mm. Both materials were tested individually as well as their combination. Epoxy and polyurethane (PUR) adhesives were used for the glued dowel joints. When the same materials were bonded, maximum load carrying capacity was achieved with PUR adhesive, material combination of plastic-plastic, and moisture content of 90%. The epoxy adhesive was most suitable for bonding materials with different properties.


2018 ◽  
Vol 162 ◽  
pp. 04005
Author(s):  
Kaiss Sarsam ◽  
Raid Khalel ◽  
Mohammed Hadi

An experimental study was carried out to investigate the behavior of normal strength reinforce concret (RC) circular short column strengthned with “carbon fiber reinforced polymer (CFRP) sheets”. Three series comprising totally of (15) specimens loaded until failure under concentric compresion load. Strengthening was varied by changing the number of CFRP strips, spacing and wrapping methods. The findings of this research can be summarized as follows: for the columns without CFRP, the influence of the tie spacing was significant: compared with 130 mm tie spacing, dropping the spacing to 100 mm and 70 mm increased the load carrying capacity by 18% and 26%, respectively. The columns with less internal confinement (lesser amount of ties) were strengthened more significantly by the CFRP than the ones with greater amount of internal ties. As an example of the varying effectiveness of the fully wrapped CFRP, the column with ties at 130 mm was strengthened by 90% with the CFRP. In contrast, the ones with 70 mm spaced ties only increased in strength with CFRP by 66%. Compared with the control specimen (no CFRP), the same amount of CFRP when used as hoop strips led to more strengthening than using CFRP as a spiral strip- the former led to nearly 9% more strengthening than the latter in the case of 130 mm spaced internal steel ties. In the case of 100 mm internal steel ties, the difference (between the hoops & spiral CFRP strengthening) is close to 4%. In contrast, there is no difference between the two methods of strengthening in the heavily tied columns (70 mm tied spacing).


2019 ◽  
Vol 105 ◽  
pp. 76-84
Author(s):  
NADEŽDA LANGOVÁ ◽  
PAVOL JOŠČÁK

Mechanical Properties of Confirmat Screws Corner Joints Made of Native Wood and Wood-Based Composites. The aim of this investigation was to design and determine the mechanical properties of confirmat screws corner joints made of native wood and wood-based composites. The objective of the study was to ascertain the stiffness and load carrying capacity of joints that differed in the diameter and length of confirmat type screw, as well as in the kind of materials. The results include statistical processing of measured and calculated data, and evaluation of the influence of selected factors on mechanical properties. The results are applied to the calculation of the characteristic values of the properties and to the determination of the equations for their calculation for other values of the selected factors. The characteristic values are used for the evaluation of the joints according to the limit state method.


In this paper, 1 group of plain concrete square columns 150×150×600 mm and 11 groups of concrete columns reinforced with glass fiber reinforced polymer (GFRP) were cast and tested, each group contains of 3 specimens. These experiments investigated effect of the main reinforcement ratio, stirrup spacing and contribution of longitudinal GFRP bars on the load carrying capacity of GFRP reinforced concrete (RC) columns. Based on the experiment results, the relationship between load-capacity and reinforcement ratio and the plot of contribution of longitudinal GFRP bars to load-capacity versus the reinforcement ratio were built and analyzed. By increasing the reinforcement ratio from 0.36% to 3.24%, the average ultimate strain in columns at maximum load increases from 2.64% to 75.6% and the load-carrying capacity of GFRP RC columns increases from 3.4% to 25.7% in comparison with the average values of plain concrete columns. Within the investigated range of reinforcement ratio, the longitudinal GFRP bars contributed about 0.72%-6.71% of the ultimate load-carrying capacity of the GFRP RC columns. Meanwhile, with the same configuration of reinforcement, contribution of GFRP bars to load-carrying capacity of GFRP RC columns decreases when increasing the concrete strength. The influence of tie spacing on load-carrying capacity of reinforced columns was also taken into consideration. Additionally, experimental results allow us to propose some modifications on the existing formulas to determine the bearing capacity of the GFRP RC column according to the compressive strength of concrete and GFRP bars.


2019 ◽  
Vol 65 (4) ◽  
pp. 203-216 ◽  
Author(s):  
A. Ambroziak

AbstractThe aim of the research is laboratory investigation of aluminium brackets employed to fasten lightweight curtain walls to building facilities. Tensile loads perpendicular to end plates (vertical) were applied here. The author focused on the solutions intended to increase the load-carrying capacity of aluminium brackets applying the plain washer form A (DIN 125; ISO 7089), plain washer with an outer diameter about 3d (DIN 9021; ISO 7093) and additional cover plates (straps) in the location of bolt anchoring on the base plate. The aluminium brackets were tested on a steel base and concrete substrate. The flexibility of anchoring strongly affects the increase of the end plate middle point displacement and movable crosshead displacement.


Sign in / Sign up

Export Citation Format

Share Document