The Effect of Electromagnetic Pulse Treatment on Thin – Wall Bearing Ferrules Dimensional Accuracy

2014 ◽  
Vol 887-888 ◽  
pp. 1328-1332
Author(s):  
Wang Biao Qiu ◽  
Wei Xing Chen

The article based on different frequency pulse equiponderance electromagnetic destressing comparison experiment, using vertical optical measurement to survey the changes of bearing ferrules size, study the difference between the effect of different frequency electromagnetic in removing residual stress, find the frequency of magnetic treatment pulse that help to maintain the stability of the thin-wall bearing collars' size, effectively improve the cycle of bearing ferrules process .

Author(s):  
Barney E. Klamecki

The use of magnetic fields to treat manufactured parts is attractive since easy-to-produce, easy-to-control fields can be used at room temperature, in contrast to more complex treatments such as heat treatment. Little research has been done to apply magnetic treatment to the modification and control of mechanical properties, behavior and performance of manufactured parts. This paper contains descriptions of experimental studies of the effects of pulsed magnetic treatment on the residual stress in machined surfaces and in welded thin-wall tubes, and includes a qualitative explanation of some of the results in terms of dislocation density. The machined part results indicated only possibly small effects, and so further experiments were done with thin-wall tubes that were expected to be more susceptible to magnetic treatment, and a more sensitive measurement technique was used. The difference in damping of vibration of untreated and pulsed magnetically treated welded tubes was used as a measure of treatment effects. Two significant results are reported. One is that pulsed magnetic treatment increased damping by up to 20%, with smaller effects in most tests. The other result is that damping increased, decreased, increased, and so on, as the length of magnetic treatment was increased.


2012 ◽  
Vol 166-169 ◽  
pp. 3343-3347
Author(s):  
Hua Chen Liu

This paper analyzes the results of experience and rules of distribution of the cold – formed residual stress. Distribution models of residual stress in cold-formed thin-wall steel that are close to the real condition and initial stress files of ANSYS which can describe the magnitude and distribution of the residual stress are established. This method can be applicable to simulate different distribution of the residual stress. Through importing the files into the stability analysis of ANSYS, ultimate load in the effect of residual stress can be gained. The stability coefficient of cold-formed thin-wall crimping angle steel under influence of the initial bending of 1/750 is studied, comparing the result curve with the one in GB50018-2002, it is proved that the curve is reasonable and the stability coefficient of the code should be suitable to improve.


Author(s):  
J. Fang ◽  
H. M. Chan ◽  
M. P. Harmer

It was Niihara et al. who first discovered that the fracture strength of Al2O3 can be increased by incorporating as little as 5 vol.% of nano-size SiC particles (>1000 MPa), and that the strength would be improved further by a simple annealing procedure (>1500 MPa). This discovery has stimulated intense interest on Al2O3/SiC nanocomposites. Recent indentation studies by Fang et al. have shown that residual stress relief was more difficult in the nanocomposite than in pure Al2O3. In the present work, TEM was employed to investigate the microscopic mechanism(s) for the difference in the residual stress recovery in these two materials.Bulk samples of hot-pressed single phase Al2O3, and Al2O3 containing 5 vol.% 0.15 μm SiC particles were simultaneously polished with 15 μm diamond compound. Each sample was cut into two pieces, one of which was subsequently annealed at 1300° for 2 hours in flowing argon. Disks of 3 mm in diameter were cut from bulk samples.


1975 ◽  
Vol 34 (02) ◽  
pp. 426-444 ◽  
Author(s):  
J Kahan ◽  
I Nohén

SummaryIn 4 collaborative trials, involving a varying number of hospital laboratories in the Stockholm area, the coagulation activity of different test materials was estimated with the one-stage prothrombin tests routinely used in the laboratories, viz. Normotest, Simplastin-A and Thrombotest. The test materials included different batches of a lyophilized reference plasma, deep-frozen specimens of diluted and undiluted normal plasmas, and fresh and deep-frozen specimens from patients on long-term oral anticoagulant therapy.Although a close relationship was found between different methods, Simplastin-A gave consistently lower values than Normotest, the difference being proportional to the estimated activity. The discrepancy was of about the same magnitude on all the test materials, and was probably due to a divergence between the manufacturers’ procedures used to set “normal percentage activity”, as well as to a varying ratio of measured activity to plasma concentration. The extent of discrepancy may vary with the batch-to-batch variation of thromboplastin reagents.The close agreement between results obtained on different test materials suggests that the investigated reference plasma could be used to calibrate the examined thromboplastin reagents, and to compare the degree of hypocoagulability estimated by the examined PIVKA-insensitive thromboplastin reagents.The assigned coagulation activity of different batches of the reference plasma agreed closely with experimentally obtained values. The stability of supplied batches was satisfactory as judged from the reproducibility of repeated measurements. The variability of test procedures was approximately the same on different test materials.


Author(s):  
Vokulova Yu.A. Vokulova ◽  
E.N. Zhulev

This article presents the results of studying the dimensional accuracy of the bases of complete removable prostheses made using a 3D printer and the traditional method. Bases of complete removable prostheses were made using an intraoral laser scanner iTero Cadent (USA) and a 3D printer Asiga Max UV (Australia). To study the dimensional accuracy of the bases of complete removable prostheses, we used the DentalCAD 2.2 Valletta software. The Nonparametric Wilcoxon W-test was used for statistical analysis of the obtained data. We found that the average value of the difference with the standard for bases made using digital technologies is 0.08744±0.0484 mm. The average value of the difference with the standard for bases made by the traditional method is 0.5654±0.1611 mm. Based on these data, we concluded that the bases of complete removable prostheses made using modern digital technologies (intraoral laser scanning and 3D printer) have a higher dimensional accuracy compared to the bases of complete removable prostheses made using the traditional method with a significance level of p<0.05 (Wilcoxon's W-test=0, p=0.031). Keywords: digital technologies in dentistry, digital impressions, intraoral scanner, 3D printing, ExoCAD, complete removable dentures.


Author(s):  
Ю.И. Цой

Задача получения однородного состава ЛКМ сводится к правильному выбору пленкообразователей и соответствующих растворителей и, в случае необходимости, разбавителей и добавок. На основе положений теории растворимости была проведена оценка совместимости компонентов и стабильности таких систем. Критериями оценки были приняты параметры растворимости и термодинамического взаимодействия. Исследовали совместимость алкидных лаков с аминоформальдегидными смолами в бутаноле, и результаты этих исследований представлены в треугольной фазовой диаграмме. Для оценки совместимости смол по результатам расчета параметров термодинамического взаимодействия были построены спинодали для тройных систем. Как показывает анализ результатов проведенных исследований, даже при большой разности ?? = |?12 – ?13| = 0,2 наблюдается небольшая область несовместимости. С уменьшением разности ?? область несовместимости сужается. При ?23 > ?с область несовместимости расширяется как для ? = 0,2, так и для ?? = 0,1 и ?? = 0. Таким образом, для таких систем на совместимость компонентов, в первую очередь, влияет их взаимодействие между собой – чем оно больше, тем лучше они совместимы. Проведенные исследования показали, что парциальные параметры растворимости, учитывающие природу когезионных сил, более объективно характеризуют растворимость пленкообразующих смол в органических растворителях, чем их общий параметр растворимости. Растворимость пленкообразующих алкидных и этерифицированных аминоформальдегидных смол в органических растворителях обусловлена термодинамическим взаимодействием молекулярных сил различной природы. Стабильность смеси алкидной и этерифицированной аминоформальдегидной смолы в бутаноле обусловлена в большей степени термодинамическим взаимодействием молекулярных сил; при этом степень бутанолизации меламиноформальдегидной смолы оказывает наибольшее влияние на стабильность cистемы. Проведенные исследования по стабильности лакокрасочных смесей из различных пленкообразующих смол на основе рассмотренных критериев оценки могут быть использованы для совершенствования технологии защитно-декоративной отделки древесины. The problem of obtaining a homogeneous composition of the coatings is reduced to the proper selection of film-forming agents, and diluent and, if appropriate, diluents and additives. On the basis of the theory of solubility, we have carried out the assessment of the compatibility of the components and stability of such systems. The evaluation criteria were adopted the parameters of the solubility and thermodynamic interaction. Researched the compatibility with alkyd varnishes aminoformaldehyde resin in butanol, and the results of these studies are presented in the triangular phase diagram. To evaluate the compatibility of the resins according to the results of calculation of thermodynamic parameters of interaction were built spinodal for ternary systems. As the analysis of the results of the studies, even when the difference ??|?12 – ?13| = 0,2 there is a small area of incompatibility. With the decrease of the difference ? ? region incompatibility narrows. When ?23> ?с region incompatibility extends to ?? = 0,2, and for ?? = 0.1 and ?? = 0. Thus, for such systems, compatibility of components, primarily, affects their interaction with each other – the further away it is, the better they are compatible. Studies have shown that the partial solubility parameters, which take into account the nature of cohesive forces, more objectively characterize the solubility of film-forming resins in organic solvents than their total solubility parameter. The solubility and film-forming aminoformaldehyde esterified alkyd resins in organic solvents due to thermodynamic interaction of molecular forces of different nature. Тhe stability of the mixture and aminoformaldehyde esterified alkyd resin in butanol is generated largely by thermodynamic forces of molecular interaction; the degree of butanolate melamine-formaldehyde resin has the greatest effect on the stability of the system. Conducted research on the stability of the paint mixtures of various film-forming resins on the basis of the evaluation criteria can be used to improve the technology of protective and decorative wood finish.


2019 ◽  
Vol 12 (4) ◽  
pp. 378-382
Author(s):  
Shan Syedhidayat ◽  
Quan Wang ◽  
Al-Hadad M.A.A. Mohsen ◽  
Jinrong Wang

Background: One of the most common manufacturing equipment for polymer product is injection molding machine. In order to ensure the precise, stable and continuous operation of the injection molding machine, the maintenance of the lubrication system must be done well. The stability, reliability, rationality and low noise performance of the lubrication system of injection molding machine directly affect the quality of injection products, dimensional accuracy, molding cycle, working environment and maintenance. Objective: The purpose of this study is to introduce the methods of choice, maintenance of lubricating oil for injection molding machine from many literatures and patents in the recent years, such as lubricating oil device, lubricating composite and structure. Methods: An example of the 260M5 automatic injection molding machine is introduced for the inspection and maintenance of the lubrication system including lubricating oil and lubricating grease. Results: To ensure the lubrication of the injection molding machine, it needs to strictly observe the lubrication time and modulus of the injection molding machine. It needs to strictly control the temperature rise of the lubricating oil and select the correct lubricating oil and grease to ensure the lubrication quality. Conclusion: In the operation of the injection molding machine, it is necessary to check that the lubricating oil is sufficient and the lubricating points are working properly. It ensures sufficient lubrication of the injection molding machine and strictly observes the lubrication time and modulus of the injection molding machine. The stored lubricating oil should be sealed well to prevent air pollution.


Author(s):  
Yong Wang

The purpose of this study is to explore the stability and interaction between parental pressure and social research report, as well as the role of employment status and family income levels in this process. This study used a special study on Korean children (PSKC) 2–4 waves. Use t-test, correlation and autoregressive cross-delay modeling to analyze the data. The main findings of this study are: First, over time, parental pressure and mother’s social research report are consistent. Secondly, the pressure of motherhood and childcare has an obvious lagging effect on upbringing, and vice versa. Third, there is no significant difference between working mothers and non-working mothers in terms of the stability of working parents' pressure, social research report and social research report for children's pressure channels. However, parental pressure can only predict the social research report of working mothers. Fourth, there is no significant difference between the stability and interaction of these two structures in household income levels. In short, the results show that, over time, parental pressure is consistent with mother’s social research report. The results also show that there is a significant cross-lag effect between the mothers’ perceptions of mutual pressure analysis. In the process from parental pressure to social research report, I found the difference between working and non-working mothers. The advantage of this study is that the expected longitudinal design was adopted during infancy and the priority between the two structures can be considered. The results of this study can be used as a source of intervention plans to help parents withstand severe parenting pressure and lack of social research report.


Polymers ◽  
2021 ◽  
Vol 13 (8) ◽  
pp. 1234
Author(s):  
António Sérgio Silva ◽  
Aurora Carvalho ◽  
Pedro Barreiros ◽  
Juliana de Sá ◽  
Carlos Aroso ◽  
...  

Thermal and self-curing acrylic resins are frequently and versatilely used in dental medicine since they are biocompatible, have no flavor or odor, have satisfactory thermal qualities and polishing capacity, and are easy and fast. Thus, given their widespread use, their fracture resistance behavior is especially important. In this research work, we comparatively analyzed the fracture resistance capacity of thermo and self-curing acrylic resins in vitro. Materials and Methods: Five prosthesis bases were created for each of the following acrylic resins: Lucitone®, ProBase®, and Megacryl®, which were submitted to different forces through the use of the CS® Dental Testing Machine, usually mobilized in the context of fatigue tests. To this end, a point was defined in the center of the anterior edge of the aforementioned acrylic resin bases, for which the peak tended until a fracture occurred. Thermosetting resins were, on average, more resistant to fracture than self-curable resins, although the difference was not statistically significant. The thermosetting resins of the Lucitone® and Probase® brands demonstrated behavior that was more resistant to fracture than the self-curing homologues, although the difference was not statistically significant. Thermosetting resins tended to be, on average, more resistant to fracture and exhibited the maximum values for impact strength, compressive strength, tensile strength, hardness, and dimensional accuracy than self-curing resins, regardless of brand.


2021 ◽  
Vol 13 (4) ◽  
pp. 793
Author(s):  
Guoqiang Jiao ◽  
Shuli Song ◽  
Qinming Chen ◽  
Chao Huang ◽  
Ke Su ◽  
...  

BeiDou global navigation satellite system (BDS) began to provide positioning, navigation, and timing (PNT) services to global users officially on 31 July, 2020. BDS constellations consist of regional (BDS-2) and global navigation satellites (BDS-3). Due to the difference of modulations and characteristics for the BDS-2 and BDS-3 default civil service signals (B1I/B3I) and the increase of new signals (B1C/B2a) for BDS-3, a systemically bias exists in the receiver-end when receiving and processing BDS-2 and BDS-3 signals, which leads to the inter-system bias (ISB) between BDS-2 and BDS-3 on the receiver side. To fully utilize BDS, the BDS-2 and BDS-3 combined precise time and frequency transfer are investigated considering the effect of the ISB. Four kinds of ISB stochastic models are presented, which are ignoring ISB (ISBNO), estimating ISB as random constant (ISBCV), random walk process (ISBRW), and white noise process (ISBWN). The results demonstrate that the datum of receiver clock offsets can be unified and the ISB deduced datum confusion can be avoided by estimating the ISB. The ISBCV and ISBRW models are superior to ISBWN. For the BDS-2 and BDS-3 combined precise time and frequency transfer using ISBNO, ISBCV, ISBRW, and ISBWN, the stability of clock differences of old signals can be enhanced by 20.18%, 23.89%, 23.96%, and 11.46% over BDS-2-only, respectively. For new signals, the enhancements are −50.77%, 20.22%, 17.53%, and −3.69%, respectively. Moreover, ISBCV and ISBRW models have the better frequency transfer stability. Consequently, we recommended the optimal ISBCV or suboptimal ISBRW model for BDS-2 and BDS-3 combined precise time and frequency transfer when processing the old as well as the new signals.


Sign in / Sign up

Export Citation Format

Share Document