Anderson-Stuart Model to Analyze AC and DC Conductivity of Lithium Zinc-Silicate Glass / Glass-Ceramics

2007 ◽  
Vol 280-283 ◽  
pp. 919-924
Author(s):  
M.S. Jogad ◽  
V.K. Shrikhande ◽  
A.H. Dyama ◽  
L.A. Udachan ◽  
Govind P. Kothiyal

AC and DC conductivities have been measured by using the real (e¢) and imaginary (e¢¢) parts of the dielectric constant data of glass and glass-ceramics (GC) at different temperatures in the rage 297-642K and in the frequency range 100 Hz to 10 MHz. Using Anderson –Stuart model, we have calculated the activation energy, which is observed to be lower than that of the DC conductivity. The analysis for glass/glass-ceramics indicates that the conductivity variation with frequency exhibits an initial linear region followed by nonlinear region with a maximum in the high-frequency region. The observed frequency dependence of ionic conductivity has been analyzed within the extended Anderson–Stuart model considering both the electrostatic and elastic strain terms. In glass/glassceramic the calculations based on the Anderson-Stuart model agree with the experimental observations in the low frequency region but at higher frequencies there is departure from measured data.

2007 ◽  
Vol 280-283 ◽  
pp. 915-918
Author(s):  
Shao Ze Yan ◽  
Feng Xu ◽  
Xia Jie Liu ◽  
Jin Hui Wang

AC and DC conductivities have been measured by using the real (e¢) and imaginary (e¢¢) parts of the dielectric constant data of glass and glass-ceramics (GC) at different temperatures in the rage 297-642K and in the frequency range 100 Hz to 10 MHz. Using Anderson –Stuart model, we have calculated the activation energy, which is observed to be lower than that of the DC conductivity. The analysis for glass/glass-ceramics indicates that the conductivity variation with frequency exhibits an initial linear region followed by nonlinear region with a maximum in the high-frequency region. The observed frequency dependence of ionic conductivity has been analyzed within the extended Anderson–Stuart model considering both the electrostatic and elastic strain terms. In glass/glassceramic the calculations based on the Anderson-Stuart model agree with the experimental observations in the low frequency region but at higher frequencies there is departure from measured data.


2014 ◽  
Vol 618 ◽  
pp. 519-522
Author(s):  
Guang Yu ◽  
Wen Bang Sun ◽  
Gang Liu ◽  
Mai Yu Zhou

Optical remote image is affected by thin cloud inevitably, which debases image definition. Traditional homomorphism filtering frequently used in thin cloud removing has affect on the cloud in low frequency region, but is not effective for those in high frequency region. An improved homomorphism filtering method is proposed on the basis of statistical characters of image information. Instead of the filtering in frequency field, it isolates the low frequency component of the image representing cloud information with calculating neighborhood average in spatial field. Then, the filtered image is enhanced based on rough set. The experiment results show that the proposed method compared to traditional methods can obtain good results and performs faster.


2014 ◽  
Vol 937 ◽  
pp. 465-471
Author(s):  
Xiao Ling Gai ◽  
Xian Hui Li ◽  
Rui Wu ◽  
Bin Zhang ◽  
Jun Juan Zhao

Microperforated panel (MPP) absorbers have been developed rapidly and used in many fields in recent years. First, based on the Maa’s theory, the theoretical development of MPP is reviewed in this paper. Furthermore, structure design and processing technology of MPP are introduced. Finally, the further development of MPP is discussed. Based on the MPP theory and electro-acoustical equivalent circuit principle, sound absorption properties of three-leaf microperforated panel (TMPP) absorbers without a rigid backing are studied to broaden the sound absorption bandwidth of MPP structure. Simulation results show that TMPP absorbers without a rigid backing have two resonance peaks and the energy dissipated coefficient remains constant in the low frequency range. The resonance frequency moves toward low frequency region with the increasing of the distance, thickness and pore diameter of MPP and moves toward high frequency region with the increasing of the perforation when other parameters keep invariant. The energy dissipated coefficient more than 0.5 over 8 octaves by choosing proper parameters. In conclusion, TMPP absorbers without a rigid backing have good sound absorption properties in a wide frequency range.


2013 ◽  
Vol 357-360 ◽  
pp. 1206-1211
Author(s):  
Xiao Ling Gai ◽  
Xian Hui Li ◽  
Bin Zhang ◽  
Peng Xie ◽  
Zhi Hui Ma

The sound absorption ability of screen or perforated membrane is studied based on rigid frame porous models combined with thin membrane resonance sound absorbing theory in this paper. Results show that the sound absorption of screen or perforated membrane is better considering the role of membrane than using the rigid frame porous models when the mass density of screen or perforated membrane is smaller. The rigid frame porous model is very accuracy to model the sound absorption ability of screen or perforated membrane when the mass density of membrane is greater. The parameter studies present that the sound absorption peaks move toward low frequency region with the increasing of the depth of air-back cavity, mass density and thickness of screens or perforated membrane and moves toward high frequency region with the increasing of the perforation and perforated radius of screens or perforated membrane when other parameters keep invariant.


Author(s):  
Hai Qiu ◽  
Huageng Luo ◽  
Neil Eklund

Roller bearing prognosis requires the detection of a bearing defect signature in the earliest possible stage in order to avoid a minor or catastrophic mechanical failure. Defects can occur in any of the bearing parts, inner and outer race, cage and rolling elements. It is possible to identify the defective component of the bearing based on the specific vibration frequencies that are excited. However, the pattern of vibration spectrum changes as the bearing deteriorates through different stages. Depending on which failure stage the bearing is in, different techniques are required to find fault signatures in different frequency ranges. Techniques such as enveloping analysis that works in the high frequency region require higher data sampling rates and therefore more expensive data acquisition hardware than techniques conducted in low frequency region. This paper compares two popular rolling element bearing diagnostics techniques — spectrum analysis in the bearing characteristic frequency range and enveloping analysis in the high frequency range — using aircraft engine test rig data. The techniques are compared both in terms of the time of detection and data sampling requirement; this analysis provides guidance for technology adoption in future field deployment. Results demonstrate that enveloping analysis is able to detect bearing defects much earlier than the spectrum analysis, but it requires a higher data sampling rate. The bearing defect characteristic frequency is detectable in low frequency spectrum only in the late stage of the failure and it is contaminated by other harmonics such as shaft unbalance. From a practical perspective, the final choice of the technology adopted for deployment should be based on an analysis of hardware requirements and tolerance of detection latency.


2021 ◽  
Vol 2021 ◽  
pp. 1-10
Author(s):  
Jiming Chen ◽  
Liping Chen ◽  
Mohammad Shabaz

In the present scenario, image fusion is utilized at a large level for various applications. But, the techniques and algorithms are cumbersome and time-consuming. So, aiming at the problems of low efficiency, long running time, missing image detail information, and poor image fusion, the image fusion algorithm at pixel level based on edge detection is proposed. The improved ROEWA (Ratio of Exponentially Weighted Averages) operator is used to detect the edge of the image. The variable precision fitting algorithm and edge curvature change are used to extract the feature line of the image edge and edge angle point of the feature to improve the stability of image fusion. According to the information and characteristics of the high-frequency region and low-frequency region, different image fusion rules are set. To cope with the high-frequency area, the local energy weighted fusion approach based on edge information is utilized. The low-frequency region is processed by merging the region energy with the weighting factor, and the fusion results of the high findings demonstrate that the image fusion technique presented in this work increases the resolution by 1.23 and 1.01, respectively, when compared to the two standard approaches. When compared to the two standard approaches, the experimental results show that the proposed algorithm can effectively reduce the lack of image information. The sharpness and information entropy of the fused image are higher than the experimental comparison method, and the running time is shorter and has better robustness.


1974 ◽  
Vol 29 (7) ◽  
pp. 1011-1016
Author(s):  
W. Nitsch ◽  
H. J. Falge ◽  
R. Claus

Polar phonon modes in single crystalline K3Cu(CN)4 and K3Ag(CN)4 have been experimentally studied by light scattering. Measurements at 293, 82 and 6 K made possible assignments in the low frequency region from 0 to about 700 cm-1 and the high frequency region from 2030 to about 2100 cm-1 originating from the C≡N stretching vibrations. Directional dispersion due to the anisotropy of K3Cu(CN)4 has been studied and allowed the identification of the transversal and longitudinal vibrations in the high frequency region. IR-reflectivity measurements, partly on the basis of the ATR-method, have been used in order to support the assignments in this region.


2020 ◽  
Vol 19 ◽  

Circular and annular domains of hydroacoustic vibration are very common in modern technology due to their simplicity. On the other hand it turns out that such a shape possesses remarkable vibration properties. It is determined that there are two classes of resonant rotating waves, predominantly tangential and predominantly radial, in terms of prevalence of tangential or radial components of the vectors of vibrational velocities and displacements. The complete map of resonant angular velocities shows that all predominantly tangential angular velocities for all values of ring thickness are assembled into the self-isolating unique single low-frequency branch, whereas predominantly radial ones fill the entire high-frequency region very densely.


2012 ◽  
Vol 23 (09) ◽  
pp. 722-732 ◽  
Author(s):  
Håkan Hua ◽  
Björn Johansson ◽  
Radi Jönsson ◽  
Lennart Magnusson

Background: Adults with cochlear implants (CIs) are usually implanted unilaterally. To preserve binaural advantages, a noninvasive method involves maintaining the hearing aid (HA) on the contralateral ear; the choice of HA for this purpose is therefore crucial. In recent years, the use of frequency transposition has gained a renewed interest in clinical practice. This type of processing records information from the high-frequency region and conveys it to a low-frequency region where there is still some residual hearing. Purpose: To conduct an investigation and examine whether adults with unilateral CI derive benefits from a HA utilizing linear frequency transposition (LFT) on the contralateral ear. Research Design: A two-period, single-blind, repeated-measures crossover design was conducted to examine the combination of LFT in conjunction with a CI. Speech recognition tests were performed in quiet and in noise with LFT either activated or deactivated. The Speech, Spatial and Qualities of Hearing Questionnaire (SSQ) was used to measure subjective benefit. Study Sample: The participants were nine frequent bimodal users, five males and four females, with a moderate to profound high-frequency sensorineural hearing loss in the nonimplanted ear. Intervention: The current study was conducted using the Widex Mind440 power (m4-19) behind-the-ear HA. The participants acted as their own control in a total of seven conditions: (1) bimodal with own HA, (2) CI only, (3) own HA alone, (4) bimodal new HA LFT-off, (5) new HA LFT-off, (6) bimodal new HA LFT-on, and (7) new HA LFT-on. Data Collection and Analysis: Monosyllabic words in quiet and the Swedish version of Hearing in Noise Test (HINT) were used as speech test materials. Stimuli were presented in sound field at a speech level of 65 dB sound pressure level (SPL) via a loudspeaker at a distance of 1 m from the participant in a sound-treated room. The SSQ was administered in each session evaluating the three bimodal conditions. SPSS software was used for statistical analyses. General linear model (GLM) analysis of variance for repeated measures was performed and followed with Bonferroni-adjusted post hoc pairwise comparisons. Results: Participants performed better with CI only than with HA alone, and the bimodal conditions were superior to the CI alone. No significant differences (p > .05) were observed when comparing the LFT-on with LFT-off regardless of whether the use of CI was included in the different listening conditions in objective and subjective measurements. Conclusions: The results suggest an advantage for CI patients with a HA in the opposite ear, and that the LFT neither degraded nor enhanced speech performance in conjunction with a CI in quiet or in noise in comparison to when it was deactivated.


2013 ◽  
Vol 705 ◽  
pp. 52-55 ◽  
Author(s):  
Yurii Kabirov ◽  
Victor Gavrilyachenko ◽  
Evgeni Panchenko ◽  
Evgeni Milov ◽  
Anatoly Klenushkin

The dielectric spectrum of CaCu3Ti4O12samples prepared by traditional "one step" ceramic technology is analyzed. It is established that the characteristic Debye-type dispersion with an activation energy 0, 075 eV manifests in the high-frequency range (f ~ 106Hz). In the low-frequency region (f< 102Hz) a transition from giant permittivity values to its negative values is detected in some samples. Conditions for such transition are discussed.


Sign in / Sign up

Export Citation Format

Share Document