Application of Diode Lasers in Interferometrical Length Measurements

2010 ◽  
Vol 437 ◽  
pp. 423-427 ◽  
Author(s):  
Alexander Höink ◽  
Karl Meiners-Hagen ◽  
Otto Jusko ◽  
Ahmed Abou-Zeid

The experimental results for the determination of the form of thin cylinders (Ø ~ 2.5 mm) as well as step heights of gauge blocks (~ 100 µm) and roundness profiles of test samples from metal or glass with different diameters between ~ 2.5 mm and 80 mm using two multi-wavelength diode laser interferometers are presented and discussed.

2009 ◽  
Vol 9 (1) ◽  
Author(s):  
K. Meiners-Hagen ◽  
R. Schödel ◽  
F. Pollinger ◽  
A. Abou-Zeid

2007 ◽  
Vol 15 (2) ◽  
Author(s):  
T. Czyszanowski ◽  
W. Nakwaski

AbstractOptical model, scalar or vectorial one, describing behaviour of an optical field within a diode-laser cavity, is one of the most important parts of modelling of a diode-laser operation. As compared to more accurate vectorial optical approaches, scalar ones are known to be less exact but simultaneously they need much less computation time. Besides, they have been sometimes found to be surprisingly exact even beyond their confirmed range of validity. Therefore, in this paper, real validity limits of their application have been determined by comparing their simplified results with more exact results obtained with the aid of vectorial models. The analysis comprises a comparison of an application of the most popular scalar approach to optical properties of diode lasers, i.e., the effective index method, and the vectorial method of lines for the standard 1.3-µm GaAs-based stripe-geometry diode laser. The scalar model has been found to be quite exact in the case of a determination of the effective refractive index, i.e., the wavelength of emitted radiation, whereas its exactness in the lasing threshold analysis is much worse, especially in the case of higher-order modes. Our analysis is concluded with a determination of the regions where both models give satisfactorily close results.


2020 ◽  
Vol 835 ◽  
pp. 229-242
Author(s):  
Oboso P. Bernard ◽  
Nagih M. Shaalan ◽  
Mohab Hossam ◽  
Mohsen A. Hassan

Accurate determination of piezoelectric properties such as piezoelectric charge coefficients (d33) is an essential step in the design process of sensors and actuators using piezoelectric effect. In this study, a cost-effective and accurate method based on dynamic loading technique was proposed to determine the piezoelectric charge coefficient d33. Finite element analysis (FEA) model was developed in order to estimate d33 and validate the obtained values with experimental results. The experiment was conducted on a piezoelectric disc with a known d33 value. The effect of measuring boundary conditions, substrate material properties and specimen geometry on measured d33 value were conducted. The experimental results reveal that the determined d33 coefficient by this technique is accurate as it falls within the manufactures tolerance specifications of PZT-5A piezoelectric film d33. Further, obtained simulation results on fibre reinforced and particle reinforced piezoelectric composite were found to be similar to those that have been obtained using more advanced techniques. FE-results showed that the measured d33 coefficients depend on measuring boundary condition, piezoelectric film thickness, and substrate material properties. This method was proved to be suitable for determination of d33 coefficient effectively for piezoelectric samples of any arbitrary geometry without compromising on the accuracy of measured d33.


Micromachines ◽  
2021 ◽  
Vol 12 (6) ◽  
pp. 710
Author(s):  
Michał Michalik ◽  
Jacek Szymańczyk ◽  
Michał Stajnke ◽  
Tomasz Ochrymiuk ◽  
Adam Cenian

The paper deals with the medical application of diode-lasers. A short review of medical therapies is presented, taking into account the wavelength applied, continuous wave (cw) or pulsed regimes, and their therapeutic effects. Special attention was paid to the laryngological application of a pulsed diode laser with wavelength 810 nm, and dermatologic applications of a 975 nm laser working at cw and pulsed mode. The efficacy of the laser procedures and a comparison of the pulsed and cw regimes is presented and discussed.


2018 ◽  
Vol 233 ◽  
pp. 00025
Author(s):  
P.V. Polydoropoulou ◽  
K.I. Tserpes ◽  
Sp.G. Pantelakis ◽  
Ch.V. Katsiropoulos

In this work a multi-scale model simulating the effect of the dispersion, the waviness as well as the agglomerations of MWCNTs on the Young’s modulus of a polymer enhanced with 0.4% MWCNTs (v/v) has been developed. Representative Unit Cells (RUCs) have been employed for the determination of the homogenized elastic properties of the MWCNT/polymer. The elastic properties computed by the RUCs were assigned to the Finite Element (FE) model of a tension specimen which was used to predict the Young’s modulus of the enhanced material. Furthermore, a comparison with experimental results obtained by tensile testing according to ASTM 638 has been made. The results show a remarkable decrease of the Young’s modulus for the polymer enhanced with aligned MWCNTs due to the increase of the CNT agglomerations. On the other hand, slight differences on the Young’s modulus have been observed for the material enhanced with randomly-oriented MWCNTs by the increase of the MWCNTs agglomerations, which might be attributed to the low concentration of the MWCNTs into the polymer. Moreover, the increase of the MWCNTs waviness led to a significant decrease of the Young’s modulus of the polymer enhanced with aligned MWCNTs. The experimental results in terms of the Young’s modulus are predicted well by assuming a random dispersion of MWCNTs into the polymer.


1993 ◽  
Vol 16 (2) ◽  
pp. 63-70 ◽  
Author(s):  
N.A. Hoenich ◽  
P.T. Smirthwaite ◽  
C. Woffindin ◽  
P. Lancaster ◽  
T.H. Frost ◽  
...  

Recirculation is an important factor in single needle dialysis and, if high, can compromise treatment efficiency. To provide information regarding recirculation characteristics of access devices used in single needle dialysis, we have developed a new technique to characterise recirculation and have used this to measure the recirculation of a Terumo 15G fistula needle and a VasCath SC2300 single lumen catheter. The experimentally obtained results agreed well with those established clinically (8.5 ± 2.4% and 18.4 ± 3.4%). The experimental results have also demonstrated a dependence on access type, pump speeds and fistula flow rate. A comparison of experimental data with theoretical predictions showed that the latter exceeded those measured with the largest contribution being due to the experimental fistula.


2009 ◽  
Vol 10 (9) ◽  
pp. 907-915 ◽  
Author(s):  
Koichi M.T. Yamada ◽  
Atsushi Onae ◽  
Feng-Lei Hong ◽  
Hajime Inaba ◽  
Tadao Shimizu

2014 ◽  
Vol 698 ◽  
pp. 466-471
Author(s):  
Oleg V. Panchenko ◽  
Alexey M. Levchenko ◽  
Victor A. Karkhin

Specimens of various sizes are used to determine hydrogen content in deposited metals in such standards as ISO 3690, AWS A 4.3, and GOST 23338 while measuring methods are the same. It causes problems in comparison of experimental results and brings up the following question: what kind of specimen size is optimal to determine hydrogen content? An optimal specimen size was estimated using a calculation method. Experimental and calculation results obtained by using specimens with estimated dimensions were compared to the results obtained by using the specimen with dimensions of 100*25*8 mm to determine hydrogen content in a deposited metal.


Sign in / Sign up

Export Citation Format

Share Document