Assessment of Corrosion Behavior in Artificial Saliva of Wires for Orthodontic Applications

2018 ◽  
Vol 917 ◽  
pp. 197-201
Author(s):  
Aphinan Phukaoluan ◽  
Anak Khantachawana ◽  
Pongpan Kaewtatip ◽  
Surachai Dechkunakorn

The aim of this study, the corrosion behavior of TiNiCu in artificial saliva (pH5.35) at 37°C was assessed by the use of electrochemical methods. Ti50Ni43Cu7 (at%) used in this study were made from ingots prepared by the vacuum arc melting (VAM) method. The furnace was purged with argon gas during melting. All melted ingots were then homogenized at 800°C for 3.6 ks. Open circuit potential (OCP) was monitored at 3.6 ks followed by potentiodynamic techniques. The results showed that all chemical composition of orthodontic wires by EPMA were Ti, Ni, Cu, Cr, Fe and Mn. Surface roughness was measured in order to ensure that TiNiCu and SS was significant difference which might affect corrosion resistance. It was seen that TiNiCu orthodontic wires, presented a good corrosion resistance, compared to the stainless steel, probably due to the formation of a protective oxide film mainly constituted by titanium oxide.

2011 ◽  
Vol 378-379 ◽  
pp. 650-654 ◽  
Author(s):  
A. Phukaoluan ◽  
Anak Khantachawana ◽  
S. Dechkunakorn ◽  
N. Anuwongnukroh ◽  
P. Santiwong ◽  
...  

The aim of this study is to investigate effect of Cu and Co additions on corrosion behavior of NiTi shape memory alloys for orthodontic application. Ni50.6Ti49.4, Ti49Ni46Cu5 and Ti50Ni47Co3 (at%) alloys were prepared. The specimens were melted by arc-melting furnace and homogenized at 800oC for 3.6 ks. Transformation temperatures were analyzed by differential scanning calorimeter (DSC). The corrosion behavior was assessed electrochemically in artificial saliva (pH 5.35) at 37oC. Open circuit potential (OCP) was monitored 3.6 ks followed by potentiodynamic techniques. The results show that all of specimens revealed transformation temperature close to oral temperature which may be utilized as orthodontic wire. Surface roughness was measured in order to ensure that there is no significant difference which might affect corrosion resistance. It is seen that by adding Co and Cu into NiTi alloys, the corrosion potential (Ecorr) and pitting corrosion potential (Ebreak) increase resulting in lower corrosion rate. Conceivably, Co and Cu additions considerable affect the corrosion behavior of NiTi alloys by improving corrosion resistance in artificial saliva.


Materials ◽  
2021 ◽  
Vol 14 (16) ◽  
pp. 4635
Author(s):  
Farah Bechir ◽  
Simona Maria Bataga ◽  
Elena Ungureanu ◽  
Diana Maria Vranceanu ◽  
Mariana Pacurar ◽  
...  

Cobalt-chromium (Co-Cr) alloys are widely utilized in dentistry. The salivary pH is a significant factor, which affects the characteristics and the behavior of dental alloys through corrosion. This study aimed to evaluate the corrosion behavior in artificial saliva with different pH values (3, 5.7, and 7.6) of two commercial Co-Cr dental alloys manufactured by casting and by milling. Corrosion resistance was determined by the polarization resistance technique, and the tests were carried out at 37 ± 1 °C, in Carter Brugirard artificial saliva. After the electrochemical parameters, it can be stated that the cast Co-Cr alloy has the lowest corrosion current density, the highest polarization resistance, and the lowest speed of corrosion in artificial saliva with pH = 7.6. In the case of milled Co-Cr alloy, the same behavior was observed, but in artificial saliva with pH = 5.7, it recorded the most electropositive values of open circuit potential and corrosion potential. Although both cast and milled Co-Cr alloys presented a poorer corrosion resistance in artificial saliva with a more acidic pH value, the milled Co-Cr alloy had better corrosion behavior, making this alloy a better option for the prosthetic treatment of patients suffering from GERD.


2021 ◽  
Vol 63 (6) ◽  
pp. 505-511
Author(s):  
Songkran Vongsilathai ◽  
Anchaleeporn Waritswat Lothongkum ◽  
Gobboon Lothongkum

Abstract A new duplex 25Cr-3Ni-7Mn-0.66 N alloy was prepared in a vacuum arc re-melting furnace and characterized by metallographic and EPMA methods. Its corrosion behavior was investigated by potentiodynamic polarization, electrochemical impedance spectroscopy (EIS) and a Mott-Schottky (M-S) analysis in artificial seawater at room temperature and compared with those of super and normal commercial duplex stainless steel (SDSS and DSS). No significant difference in the open circuit potentials and pitting potentials was observed. Its passive film current density lies between those of SDSS and DSS. This was confirmed by EIS analysis. A pit attack was observed on the δ-phase for all duplex samples, because the PREN16 of the δ-phase was lower than that of the γ-phase. From the Mott-Schottky analysis, the passive films were found to be composed of bi-layer structures, a p-type semiconductor inner layer, and a n-type semiconductor outer layer. The degree of defect as well as the effect of nitrogen in passive film layer are discussed with respect to the point defect model.


2017 ◽  
Vol 15 (1) ◽  
pp. 19-24 ◽  
Author(s):  
Davide Prando ◽  
Andrea Brenna ◽  
Fabio M. Bolzoni ◽  
Maria V. Diamanti ◽  
Mariapia Pedeferri ◽  
...  

Background Titanium has outstanding corrosion resistance due to the thin protective oxide layer that is formed on its surface. Nevertheless, in harsh and severe environments, pure titanium may suffer localized corrosion. In those conditions, costly titanium alloys containing palladium, nickel and molybdenum are used. This purpose investigated how it is possible to control corrosion, at lower cost, by electrochemical surface treatment on pure titanium, increasing the thickness of the natural oxide layer. Methods Anodic oxidation was performed on titanium by immersion in H2SO4 solution and applying voltages ranging from 10 to 80 V. Different anodic current densities were considered. Potentiodynamic tests in chloride- and fluoride-containing solutions were carried out on anodized titanium to determine the pitting potential. Results All tested anodizing treatments increased corrosion resistance of pure titanium, but never reached the performance of titanium alloys. The best corrosion behavior was obtained on titanium anodized at voltages lower than 40 V at 20 mA/cm2. Conclusions Titanium samples anodized at low cell voltage were seen to give high corrosion resistance in chloride- and fluoride-containing solutions. Electrolyte bath and anodic current density have little effect on the corrosion behavior.


Materials ◽  
2019 ◽  
Vol 12 (11) ◽  
pp. 1869 ◽  
Author(s):  
Tingzhu Jin ◽  
Weifang Zhang ◽  
Ning Li ◽  
Xuerong Liu ◽  
Lu Han ◽  
...  

Surface characterization and corrosion behavior of 90/10 copper-nickel alloy in seawater from Xiamen bay at 30 °C for 56 days were investigated in this study. The results indicated that the corrosion product layer was mainly a mixture of CuO, Cu2O, and Cu(OH)2, with a transition to CuCl, CuCl2, and Cu2(OH)3Cl during the corrosion process. However, as corrosion proceeds, the resistance of the product film was reduced due to its heterogeneous and fairly porous structures, which led to local corrosion of the alloy. The corrosion potentials (Ecorr) increase while corrosion current densities (Icorr) decrease with time because of the formation of protective oxide film.


Author(s):  
A. Christy Catherine Mary ◽  
J. Jeyasundari ◽  
V.R. Nazeera Banu ◽  
R. Dorothy ◽  
Susai Rajendran ◽  
...  

1970 ◽  
Vol 25 ◽  
pp. 53-61
Author(s):  
Minu Basnet ◽  
Jagadeesh Bhattarai

The corrosion behavior of the sputter-deposited nanocrystalline W-Cr alloys wasstudied in 0.5 M NaCl and alkaline 1 M NaOH solutions at 25°C, open to air usingimmersion tests and electrochemical measurements. Chromium metal acts synergisticallywith tungsten in enhancing the corrosion resistance of the sputter-deposited W-Cr alloys soas to show higher corrosion resistance than those of alloy-constituting elements in both 0.5M NaCl and 1 M NaOH solutions. In particular, the nanocrystalline W-Cr alloys containing25-91 at% chromium showed about one order of magnitude lower corrosion rates (that is,about 1-2 × 10-3 mm.y-1) than those of tungsten and chromium metals even for prolongedimmersion in 0.5 M NaCl solution at 25°C. On the other hand, the corrosion rate of thesputter-deposited W-Cr alloys containing 25-75 at % chromium was decreased significantlywith increasing chromium content and showed lowest corrosion rates (that is, 1.5-2.0 × 10-3 mm.y-1) after immersed for prolonged immersion in 1 M NaOH solution. The corrosion ratesof these nanocrystalline W-(25-75)Cr alloys are nearly two orders of magnitude lower thanthat of tungsten and more than one order of magnitude lower corrosion rate than that ofsputter-deposited chromium metal in 1 M NaOH solution. The corrosion-resistant of all theexamined sputter-deposited W-Cr alloys in 0.5 M NaCl solution is higher than in alkaline 1M NaOH solution at 25°C. Open circuit potentials of all the examined W-Cr alloys areshifted to more noble direction with increasing the chromium content in the alloys afterimmersion for 72 h in both 0.5 M NaCl and 1 M NaOH solutions at 25°C, open to air.Keywords: Sputter deposition, nanocrystalline W-Cr alloys, corrosion test, electrochemicalmeasurement, NaCl and NaOH solutions.DOI:  10.3126/jncs.v25i0.3300Journal of Nepal Chemical Society Volume 25, 2010 pp 53-61


2011 ◽  
Vol 37 (3) ◽  
pp. 309-317 ◽  
Author(s):  
Eman M Anwar ◽  
Lamia S Kheiralla ◽  
Riham H Tammam

Abstract The effect of fluoride ion concentration on the corrosion behavior of Ti and Ti6Al4V implant alloys, when coupled with either metal/ceramic or all-ceramic superstructure, was examined by different electrochemical methods in artificial saliva solutions. It was concluded that increased fluoride concentration leads to a decrease in the corrosion resistance of all tested couples. The type of the superstructure also showed a significant effect on the corrosion resistance of the couple.


2016 ◽  
Vol 835 ◽  
pp. 115-120
Author(s):  
Francis Mulimbayan ◽  
Manolo G. Mena

All materials which are intended to have in contact with food and other commodities produced or processed for human consumption are called food contact materials (FCM’s). Stainless steel (SS) – a widely known metallic FCM is used mainly in processing equipment, containers and household utensils. It is known for having numerous industrial and domestic applications worldwide due to its special characteristics of having notable corrosion resistance. However, this corrosion resistance is not all-encompassing since SS may still undergo degradation when subjected to a specific corrosion-inducing environment. SS may be classified according to its microstructure. If the atoms which make up the SS can be viewed as having a face-centered cubic structure, then the alloy is said to be austenitic. This SS grades include the conventional 300-series and the newly-developed 200-series. The former has superior corrosion resistance while the latter is far cheaper. In this study, the corrosion behavior of AISI 202 SS in two different levels of dissolved oxygen (O2) and three acid concentrations was investigated using electrochemical techniques, namely, open-circuit potential (OCP) measurements and electrochemical impedance spectroscopy (EIS). As the concentration of citric acid is increased, the measured OCP values of the alloy decreased and the polarization resistance (Rp) decreased, indicating decrease in alloy stability and decline in the corrosion resistance, respectively. With regards to effects of dissolved O2, results revealed that increasing the level of dissolved O2 has consequently increased the polarization resistance and shifted the OCP to more positive values. All the generated Nyquist plots exhibited a depressed capacitive loops indicating that corrosion in the designated solution occurred with charge transfer as the rate-determining step.


Sign in / Sign up

Export Citation Format

Share Document